Locking plate combined with titanium cable for Neer type II distal clavicle fractures

Abstract

Background

There is controversy about the optimal strategy treatment of unstable distal clavicle fractures. We explored use of a surgical strategy: combination of a distal clavicle locking plate and a titanium cable. The purpose of this retrospective case series study was to evaluate the clinical outcomes of this new strategy in treating Neer type II distal clavicle fractures.

Methods

Twenty-one patients with Neer type II distal clavicle fracture were treated with a distal clavicle locking plate and a titanium cable. All patients were followed for at least one year. We retrospectively collected and reviewed follow-up data. The clinical outcomes were assessed for union rate, functional score, and complication rate.

Results

All patients achieved bony union within 6 months. The average follow-up period was 20.6 months (range12–48 months). The mean Constant score at one-year follow-up was 94.6 ± 3.3 (range 84–98), and the mean UCLA (University of California, Los Angeles) score was 33.3 ± 2.6 (range 27–35). Only one complication (wound infection) was observed during follow-up. Two patients received another operation for implant removal due to local irritation.

Conclusions

Use of a distal clavicle locking plate in combination with a titanium cable for treatment of Neer type II fractures results in high union rate, a low complication rate, and good shoulder function. This combined surgical strategy can be considered an effective method for treating unstable distal clavicle fractures.

Peer Review reports

Background

Clavicle fractures are common, accounting for 2.5–5 % of all fractures in adults and 10–15 % in children. About 10–28 % of these fractures involve the distal clavicle [1, 2]. Neer has classified distal clavicle fractures into two basic types depending on the continuity of the coracoclavicular ligament [3], and type III is a special type with intra-articular extension according to the modified Neer’s classification [4]. For Neer type II distal clavicle fracture, coracoclavicular ligaments detach from the medial fragment, and consequently these fractures are unstable and displace significantly. As conservative treatment has been reported to result in relatively high nonunion and delayed union rates [5], surgical treatment has become the preferred choice of orthopedic surgeons in dealing with Neer type II distal clavicle fractures [4, 6].

To date, multiple operative techniques have been used in treating Neer type II distal clavicle fractures, yet no single technique has been generally accepted as the gold standard treatment [1]. Recently, use of a locking plate implant with a specific contoured design has been introduced for distal clavicle fractures [7,8,9]. These implants can improve the stability of the fixation by enabling more locking screws to be inserted into the distal fragment. However, without reconstruction of coracoclavicular ligaments, this technique may not be able to oppose the vertical directed forces, so it can led to complications [2, 10]. Thus, several studies have proposed the combined use of a locking plate and a coracoclavicular stabilization technique for treating unstable distal clavicle fractures [11,12,13,14].

Titanium cables are widely used in orthopedic surgeries, and this technique for coracoclavicular stabilization has already been used successfully for the treatment of acromioclavicular (AC) joint dislocation [15]. However, the use of a titanium cable alone may be insufficient for dealing with unstable distal clavicle fractures. So, we proposed a new combined surgical strategy. Over the past several years, we have used a titanium cable combined with a distal clavicle locking plate to treat Neer type II distal clavicle fractures (Fig. 1). The aim of the present retrospective case series study was to assess clinical outcomes after this surgery; we evaluated the hypothesis that this combined surgical strategy may be an effective method for the treatment of unstable distal clavicle fractures.

Fig. 1
figure 1

a Pre-operative radiograph shows a displaced distal clavicle fracture with an increased coracoclavicular distance. b Post-operative radiograph shows an anatomical reduction

Methods

Study population

This was a retrospective case series study that was approved by the Medical Ethics Committee of our hospital. From January 2012 to March 2019, 25 patients with Neer type II distal clavicle fracture were treated with a combined surgical technique (using a locking plate combined with a titanium cable) in our hospital (a Level 1 trauma center). The inclusion criteria were patients with acute fractures (within 3 weeks of injury) and patients who aged at least 18 years. Our exclusion criteria included pathological fracture, old fracture, open fracture, multiple fracture, concomitant plexus, or nerve injuries. We also excluded patients with existing severe systemic diseases as well. We also excluded patients who were lost to follow-up. On admission, X-rays of the injured shoulder were obtained for all patients. To facilitate comparison of displacement status, radiographs of the contralateral shoulder were also obtained. All patients were treated by the same team and gave written informed consent prior to operation.

Surgical technique

All surgeries were performed under general anesthesia with patients placed in the beach-chair position. Before skin preparation and draping, coracoid process and acromion were marked on the skin with a marker pen. An 8-10 cm curved incision was made over the distal clavicle to the acromion; we then dissected directly to the clavicle. And the coracoid process was carefully exposed by separating the deltoid fibers. Once the medial and lateral fragment were identified, we curetted hematoma and soft tissue between the fracture ends. Usually, it was not difficult to reduce the fracture; we reduced the fracture manually or by using a pointed reduction forceps. Then, one or two Kirschner wires were inserted from the lateral fragment to the shaft of the clavicle to provisionally immobilize the fracture. In cases with comminuted fragments, the insertion of Kirschner wires across the acromioclavicular joint was employed as an alternative method. Once the fracture reduction had been confirmed by fluoroscopy, a distal clavicle anatomical locking plate (ITS, Austria) was secured to the distal clavicle. This locking plate enabled the insertion of six-to-eight 2.4mm locking screws into the lateral fragment. In order to reinforce vertical stability, a multistrand titanium cable (Medtronic, USA) was used as a complement. We applied the titanium cable around the base of the coracoid process and across the superior surface of the plate or passed it through holes that were pre-drilled in the clavicle. Then the titanium cable loop was tightened and secured with a tensioner instrument to maintain the vertical stability of the fracture. A technical detail here should be emphasized: when using a tensioner instrument to tighten the titanium cable loop, the coracoclavicular distance should not be excessively reduced, because it may limit the normal subtle motion of the acromioclavicular joint. Fluoroscopy was performed again to confirm the reduction and the placement of implants. The surgical procedures are presented in Fig. 2.

Fig. 2
figure 2

Illustration of the surgical procedures

Postoperative care

As this surgical technique provides stable fixation for the fracture in both the vertical and horizontal directions, no shoulder sling was used routinely. Only two patients (both of whom were older than 65 years) were placed into a shoulder sling (for 4weeks postoperatively, owing to their concomitant osteoporosis). Passive exercises were started within three days after surgery. We typically recommended a passive pendulum exercise to the patients as the postoperative daily training program. Four weeks after the operation, active motion of the injured shoulder with no weight bearing was encouraged. Full range of motion without resistance was allowed from 6 to 8 weeks after the operation, and weight lifting started from postoperative weeks 8–10. Once osseous union was confirmed on radiographs, unrestricted use of the injured extremity was encouraged.

Follow‐up and outcome evaluation

All of the patients included in our study had a follow-up of at least one year. The mean follow-up was 21 months, ranging from 12 to 48 months. Follow-up evaluations of clinical outcomes and complications were performed at 6 weeks, 12 weeks, 6 months, and 12 months after surgery and annually thereafter. Radiographs were obtained at each visit to assess fracture healing, loss of reduction, and migration of implants. The range of motion was recorded at each follow-up, and shoulder function was evaluated using the Constant score and the modified UCLA score. The visual analog scale (VAS) was evaluated as well. We retrospectively reviewed all radiographs and medical records as well as complications.Data were collected independently by two reviewers prior to further data analysis using SPSS software (version 22.0, IBM, USA).

Results

A total of 21 cases with at least one year of follow-up were included in this study. There were 15 males and 6 females, with a mean age of 43.1 years (range18–68 years). Over a half of the patients conditions resulted from falling down (13 patients, 61.9 %); the remainder were caused by traffic accidents (5 bicycle accidents and 3 motor vehicle accidents). The average duration between injury and surgery was 2.4 days (range1–7 days). Operative procedures took a mean time of 86 min (range70–110 min), with an average intraoperative blood loss of 203.3 ml (range130–330 ml). All patients achieved osseous union within half a year, with 13 achieving osseous union within three months (accounting for 61.9 %). The average follow-up period was 20.6 months (range12–48 months). The detailed patient demographics and clinical data are summarized in Table 1.

Table 1 Patient demographics and clinical data

At the one-year follow-up, all patients had achieved range of motion to a degree that satisfied criteria for “recovery” for both flexion and rotation. The mean forward flexion was 158.3 ± 5.1°(range150–165°); the external and internal rotation values were 49.6 ± 2.3° (range 45–52°) and 10.3 ± 1.4°(range8–12°) respectively. The mean visual analog scale score was 1.1 ± 1.0 (range0–3). The mean Constant score of the injured shoulder at the one-year follow-up was 94.6 ± 3.3 (range 84–98), and the mean UCLA score was 33.3 ± 2.6 (range 27–35). Twenty patients (accounting for 95.2 %) acquired satisfactory shoulder function within one year according to the UCLA scoring system (including 13 patients with excellent function and 7 patients with good function) (Table 2; Figures 3 and 4).

Fig. 3
figure 3

The one-year UCLA score outcome: over 95% of the patients acquired a good or excellent shoulder function recovery within one year

Fig. 4
figure 4

Radiological and functional outcomes of a 46-year-old male with unstable distal clavicle fracture. a Pre-operative radiograph showed a Neer type II fracture of the left clavicle. b Post-operative radiograph showed an anatomical reduction. c At the six-month follow-up, the fracture achieved osseous union and no implant loosening or migration occurred. d-g The patient was satisfied with the shoulder function recovery (the Constant score was 98 and the UCLA score was 35 at the one-year follow-up)

Table 2 Functional outcome at One-year Follow-up

Only one patient experienced a complication during follow-up. A 55-year-old male was diagnosed with a surgical site infection two weeks postoperatively. The infection was limited to superficial tissue, and was treated successfully with dressing changing and antibiotics. No implant loosening or other complications were found during his subsequent follow-ups. Two patients received another operation for implant removal because of hardware prominence at one year after surgery. For both of these cases, the distal clavicle remained in the anatomical position after removal of the implants.

Discussion

Surgical treatment is recommended for Neer type II distal clavicle fractures due to the high rate of nonunion and complications associated with conservative treatment [2, 4]. Although some modified classification and a variety of surgical strategies have been proposed in recent studies, the preferred method for treating Neer type II distal clavicle fractures remains controversial [16, 17]. Hook plate fixation has been demonstrated as an effective treatment for management of unstable distal clavicle fracture [18]. This plate prevents superior translation of the medial clavicle while also providing stable fixation of the fracture. However, the relatively high complication rate, as well as the need for a second operation to remove the implant, have limited its utility [19, 20].

The use of a precontoured locking plate has been reported as another effective treatment [7,8,9]. The specific contoured design allows for additional numbers of locking screws to be inserted into the distal fragment, which can reinforce the fracture fixation. However, for comminuted fracture with poor bone quality, locking plate fixation alone may be insufficient for maintaining stability [21]. Given that the coracoclavicular ligament is known to function in providing stability to the medial fracture fragment, especially in the vertical direction, a CC stabilization technique is necessary [10, 22]. CC screw fixation is a classic method for CC stabilization that has been widely used, yet because this technique employs rigid fixation for the CC ligament, subtle motion of the AC joint is limited [23]. As the subtle motion of AC joint is part of normal shoulder girdle function, an ideal method for CC stabilization should be able to both sustain AC joint stability while also enabling subtle motion [24].

Titanium cables have excellent biomechanical properties and can provide over 1000 N bearing force for reconstructing the CC ligament [25]. The elastic characteristic of titanium cables also meets the requirement for enabling subtle AC joint motion. Ye T et al. [15] successfully used this method for management of acute AC joint dislocation. Li Y et al. [25] used a titanium cable for suspensory CC ligament fixation in treating Neer type II distal clavicle fractures, and reported good clinical outcomes. But in our experience, when dealing with comminuted unstable distal clavicle fractures, use of a titanium cable alone may not be able to maintain the stability of the fracture. Thus, we envisioned a combined surgical strategy: a distal clavicle anatomical locking plate used alongside a titanium cable. For management of unstable distal clavicle fractures, the locking plate provides a rigid fixation to the fracture, while the titanium cable provides an elastic fixation between the clavicle and coracoid. As fracture fixation is reinforced and the subtle motion of AC joint can be retained, this combined surgical strategy should offer good clinical outcomes. Indeed, all patients in the present study achieved osseous union and acquired satisfactory shoulder function, supporting that this combined surgical strategy may represent a reliable choice for orthopedic surgeons to manage unstable distal clavicle fractures.

In recent years, use of a locking plate combined with some kind of CC stabilization technique has been reported for treating unstable distal clavicle fractures [7, 10,11,12,13,14]. Rieser et al. [10] conducted a biomechanical study to evaluate the combination of a locking plate and CC reconstruction in the management of unstable distal clavicle fracture. They reported that improved fracture stability was achieved via combination of CC reconstruction and a distal clavicle locking plate compared to either intervention alone. There are similar findings from other clinical studies investigating use of a locking plate and CC ligament fixation in combination [7, 11,12,13,14]. Andersen et al. [7] described use of a pre-contoured superior locking plate in 20 patients with distal clavicle fractures. Nine of these 20 patients were also treated with either suture cerclage or CC screw fixation in addition to the plate. No fixation failure or complication related to the implants was observed during their follow-up period. However, CC screw fixation may not be optimal because it limits subtle motion of the AC joint. Instead, an elastic fixation method may be more appropriate for CC stabilization [26]. Johnston et al. [13]. Proposed a method using a suture button in addition to a locking plate. All patients in that study achieved bony union and satisfactory shoulder function recovery, which suggests that the suture button technique could act as a useful method for CC stabilization. However, the suture button technique may be more technically demanding for orthopedic surgeons, as a 2.4mm hole needs to be drilled from the distal clavicle into the base of the coracoid in order to apply the device [27]. In our study, we used a titanium cable instead of a suture button. By using a tensioner instrument, the titanium cable loop can be easily tightened and secured, making this technique much simpler and more reliable.

We compared our findings in the present study with results from six similar recent studies (Table 3). For this comparison, all patients had to be treated with either a locking T-plate or a contoured locking plate designed for the distal clavicle, and relevant studies included CC ligament fixation methods including a CC screw, suture cerclage, and a suture button. A total of 67 patients achieved osseous union (the union rate is 98.5 % overall); only one patient had an infected nonunion (reported by Andersen et al. [7]), which was subsequently treated with irrigation, debridement, hardware removal, and distal clavicle excision. A total of 10 complications were reported in the examined studies, including three implant irritations, three coracoclavicular ligaments calcifications, two infections, one peri-implant fracture, and one malreduction. In our study, only one patient suffered a complication (surgical site infection) and this was treated successfully with dress changing and antibiotics. In addition, no osteolysis or bony arrosion was detected during the follow-up. This may be due to the fact that the titanium cable acts as an elastic fixation device, so the normal subtle motion of the AC joint was barely interfered. In terms of union rate and shoulder functional outcomes, our results are similar with the examined studies.

Table 3 The retrospective series that used distal locking plates combined with CC ligament fixation are compared

Our study is subject to several limitations. First, this is a retrospective series study with limited cases, which restricts confidence for extrapolating the likelihood of success more widely. Second, lacking a control group, it is difficult to interpret from our study whether the additional CC ligament fixation conferred any extra benefit to patients. Finally, the mean follow-up period of 20.6 months may be not long enough to supporting definitive conclusions about final outcomes and/or long-term complications.

Conclusions

In conclusion, using a distal clavicle locking plate combined with a titanium cable in the management of Neer type II fractures results in a high union rate, a low complication rate, and good shoulder function. By providing rigid fixation to the fracture site and elastic fixation to the CC ligament, the fixation becomes reinforced while preserving the capacity for subtle motion of the AC joint. Our study supports that, for patients with unstable distal clavicle fractures, this modified combined surgical strategy can be regarded as an apparently reliable treatment. Despite this satisfactory result, the present evidence is insufficient to judge if this new combined surgical strategy is superior to others. Considering the limitations of this study, a prospective cohort study comparing the combined surgical strategy we explored against other surgical methods will still be needed to provide stronger evidence in support of this treatment.

Availability of data and materials

The datasets during and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

UCLA:

University of California, Los Angeles

AC:

Acromioclavicular

CC:

Coracoclavicular

VAS:

The visual analog scale

References

  1. Khan LA, Bradnock TJ, Scott C, et al. Fractures of the Clavicle. J Bone Joint Surg Am. 2009;91:447–60.

    Article  Google Scholar 

  2. Van der Meijden OA, Gaskill TR, Millett PJ. Treatment of clavicle fractures: current concepts review. J Shoulder Elbow Surg. 2012;21(3):423–9.

    Article  Google Scholar 

  3. Neer CSII. Fractures of the distal third of the clavicle. Clin Orthop Relat Res. 1968;58:43–50.

    PubMed  Google Scholar 

  4. Sambandam B, Gupta R, Kumar S, et al. Fracture of distal end clavicle: A review. J Clin Orthop Trauma. 2014;5(2):65–73.

    Article  Google Scholar 

  5. Robinson CM, Cairns DA. Primary nonoperative treatment of displaced lateral fractures of the clavicle. J Bone Joint Surg Am. 2004;86(4):778–82.

    Article  Google Scholar 

  6. Klein SM, Badman BL, Keating CJ, et al. Results of surgical treatment for unstable distal clavicular fractures. J Shoulder Elbow Surg. 2010;19(7):1049–55.

    Article  Google Scholar 

  7. Andersen JR, Willis MP, Nelson R, et al. Precontoured superior locked plating of distal clavicle fractures: a new strategy. Clin Orthop Relat Res. 2011;469(12):3344–50.

    Article  Google Scholar 

  8. Kalamaras M, Cutbush K, Robinson M. A method for internal fixation of unstable distal clavicle fractures: early observations using a new technique. J Shoulder Elbow Surg. 2008;17(1):60–2.

    Article  Google Scholar 

  9. Shin SJ, Ko YW, Lee J, et al. Use of plate fixation without coracoclavicular ligament augmentation for unstable distal clavicle fractures. J Shoulder Elbow Surg. 2016;25(6):942–8.

    Article  Google Scholar 

  10. Rieser GR, Edwards K, Gould GC, et al. Distal-third clavicle fracture fixation: a biomechanical evaluation of fixation. J Shoulder Elbow Surg. 2013;22(6):848–55.

    Article  Google Scholar 

  11. Han L, Hu Y, Quan R, et al. Treatment of Neer IIb distal clavicle fractures using anatomical locked plate fixation with coracoclavicular ligament augmentation. J Hand Surg Am. 2017;42(12): 1036.e1-1036.e6.

  12. Herrmann S, Schmidmaier G, Greiner S. Stabilisation of vertical unstable distal clavicular fractures (Neer 2b) using locking T-plates and suture anchors. Injury. 2009;40(3):236–9.

    Article  CAS  Google Scholar 

  13. Johnston PS, Sears BW, Lazarus MR, et al. Fixation of unstable type II clavicle fractures with distal clavicle plate and suture button. J Orthop Trauma. 2014;28(11):e269-72.

    Article  Google Scholar 

  14. Schliemann B, Roßlenbroich SB, Schneider KN, et al. Surgical treatment of vertically unstable lateral clavicle fractures (Neer 2b) with locked plate fixation and coracoclavicular ligament reconstruction. Arch Orthop Trauma Surg. 2013;133(7):935–9.

    Article  Google Scholar 

  15. Ye T, Ouyang Y, Chen A. Multistrand titanium cable for the coracoclavicular stabilization of acute acromioclavicular joint dislocation. Acta Orthop Belg. 2014;80(2):178–82.

    PubMed  Google Scholar 

  16. Kim DW, Kim DH, Kim BS, et al. Current Concepts for Classification and Treatment of Distal Clavicle Fractures. Clinics in orthopedic surgery. 2020;12(2):135.

    Article  Google Scholar 

  17. Stenson J, Baker W. Classifications in Brief: The Modified Neer Classification for Distal-third Clavicle Fractures. Clin Orthop Relat Res. 2021 Jan 1;479(1):205–209.

  18. Kashii M, Inui H, Yamamoto K. Surgical Treatment of Distal Clavicle Fractures Using the Clavicular Hook Plate. Clin Orthop Relat Res. 2006;447:158–64.

    Article  Google Scholar 

  19. Kanchanatawan W, Wongthongsalee P. Management of acute unstable distal clavicle fracture with a modified coracoclavicular stabilization technique using a bidirectional coracoclavicular loop system. Eur J Orthop Surg Traumatol. 2016;26(2):139–43.

    Article  Google Scholar 

  20. Cho CH, Jung JH, Kim BS. Coracoclavicular stabilization using a suture button device for Neer type IIB lateral clavicle fractures. J Shoulder Elbow Surg. 2017;26(5):804–8.

    Article  Google Scholar 

  21. Sajid S, Fawdington R, Sinha M. Locking plates for displaced fractures of the lateral end of clavicle: Potential pitfalls. Int J Shoulder Surg. 2012;6(4):126–9.

    Article  Google Scholar 

  22. Chen RE, Soin SP, El-Shaar R, et al. What Regions of the Distal Clavicle Have the Greatest Bone Mineral Density and Cortical Thickness? A Cadaveric Study. Clin Orthop Relat Res. 2019;477(12):2726–32.

    Article  Google Scholar 

  23. Macheras G, Kateros KT, Savvidou OD, et al. Coracoclavicular screw fixation for unstable distal clavicle fractures. Orthopedics. 2005;28(7):693–6.

    Article  Google Scholar 

  24. Manohara R, Reid JT. Percutaneous endobutton fixation of acute acromioclavicular joint injuries and lateral clavicle fractures. J Clin Orthop Trauma. 2019;10(3):492–6.

    Article  Google Scholar 

  25. Li Y, Shi S, Ou-Yang YP, et al. Minimally invasive treatment for Neer IIb distal clavicle fractures with titanium cable. J Trauma. 2011;71(2):37–40.

    Google Scholar 

  26. Struhl S, Wolfson TS. Closed-Loop Double Endobutton Technique for Repair of Unstable Distal Clavicle Fractures. Orthop J Sports Med. 2016;4(7):2325967116657810.

    Article  Google Scholar 

  27. Schliemann B, Roßlenbroich SB, Schneider KN, et al. Why does minimally invasive coracoclavicular ligament reconstruction using a flip button repair technique fail? An analysis of risk factors and complications. Knee Surg Sports Traumatol Arthrosc. 2015;23(5):1419–25.

    Article  Google Scholar 

Download references

Acknowledgements

We would like to thank Lei Zhu, Jiajia Lu and Zhibin Zhou for their hard work in data collecting. We also thank Dr. Luoming Zhang for her kind help in language editing.

Funding

None declared for all authors.

Author information

Authors and Affiliations

Authors

Contributions

LYZ was mainly responsible for the project. AMC designed the study. FZ outlined and wrote the manuscript with continuing support of QF and YCL. NL did the statistical analyses. All authors have made substantial contributions to the manuscript’s design and conception, acquisition of data and interpretation of data. All authors have substantially revised the manuscript critically for important content. All authors discussed the results and commented on the manuscript. All authors have read and approved the final manuscript.

Corresponding authors

Correspondence to Aimin Chen or Liangyu Zhao.

Ethics declarations

Ethics approval and consent to participate

Medical Ethics Committee of Changzheng hospital, Second Military Medical University approved a waiver of consent for this retrospective study.

Consent for publication

A written consent for publication was obtained from the patients of which images were presented.

Competing interests

The authors report that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhang, F., Fu, Q., Li, Y. et al. Locking plate combined with titanium cable for Neer type II distal clavicle fractures. BMC Musculoskelet Disord 22, 269 (2021). https://doi.org/10.1186/s12891-021-04137-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12891-021-04137-4

Keywords