Clinical advantages of gradually reducing radius versus multi-radius total knee arthroplasty: a noninferiority randomized trial

A Correction to this article was published on 16 November 2023

This article has been updated

Abstract

Background

The rationale for gradually reducing radius (GR) femoral component aims to prevent flexion instability by gradually change the center of femoral rotation, unlike a discrete change by the multi-radius (MR) which is more common for most of total knee arthroplasties (TKA). However, no strong evidence has been reported the clinical significance of the GR design.

Methods

This patient-blinded, parallel, non-inferiority trial conducted in September 2020. Patients with knee osteoarthritis consented for cruciate retaining TKA were randomly allocated to a GR or MR group. Primary outcome measures were knee functions at postoperative 6 and 12 months using the Knee injury and Osteoarthritis Outcome Score (KOOS). Secondary outcome measures were performance-based tests (30-s chair stand test, 40-m fast paced walk test, and 3-m timed up and go test), and knee motions.

Results

Sixty patients were enrolled and randomized; GR (n = 30) and MR (n = 30) group. The changes of KOOS at 6 and 12 months from baseline showed clinical meaningful for both GR and MR group. At 6 and 12 months postoperatively, there was no significant difference between both groups in all KOOS subscales. The length of stay was not different between GR and MR group (5.93 ± 1.44 vs 6.17 ± 1.86 days, p = 0.59). Patients on both groups presented similar performance-based tests. However, the improvement in degrees of knee motion for the GR group was significantly greater than the MR group (34.67 ± 12.52 vs 23.67 ± 12.59, p = 0.001).

Conclusion

GR was noninferiority to MR for the functional outcomes and performances after TKA.

The GR femoral component gave more knee motions than did the MR prostheses.

Level of evidence

Level I, therapeutic study.

Peer Review reports

Introduction

Total knee arthroplasty (TKA) is a very successful operation with an excellent outcome and survivorship results. Patient satisfaction is one of the important outcome measurements because it reflects the overall pain relief and an ability to return to normal activities of daily living after knee replacements. However, only approximately 75% of patients who had a knee replacement satisfied with the total knee arthroplasty (TKA) [1, 2]. Pain relief and knee functional gain after the TKA are sometimes overestimated and lead to patient’s unsatisfaction with the TKA [2]. Filling this gap interested clinicians over the last decades to improve surgical techniques such as less invasive surgery, tourniquet less technique, use of tranexamic acid for perioperative blood management, and periarticular injection; however, pain reduction is promising only in an acute postoperative period.

Not only the surgical technique but also an innovative implant development might be the factors increasing the outcome [3]. The evolution of prosthesis design was developed in order to gain normal knee functions. Frankle et al. [4] proposed the native knee flexion occurring around a changing transvers axis, with the instantaneous rotation center of the femoral posterior condyle forming as a “J curve” [4, 5]. The multi-radius (MR) femoral component was then theoretically invented by using the trans-epicondylar axis as a reference axis of knee flexion and rotation. A different radius of which a larger for a distal and a smaller for a posterior femoral component on the sagittal view aims to allow more degrees of freedom on knee flexion by posterior femoral roll-back and rotation [6]. The conventional MR TKA is the most commonly used design such as PFC Sigma, Depuy Synthes, Warsaw, Indiana; and Nexgen, Zimmer Biomet, Warsaw, Indiana. However, abrupt reduction between the discrete distal and posterior radii for MR TKA causes abrupt changes in the center of rotation of the femur with respect to the tibia and abrupt reductions in tibiofemoral conformity, resulted in a decrease in anterior–posterior tibiofemoral stability and mid flexion instability [7].

In 2013, Depuy Synthese launched the gradually reducing radius (GR) design (ATTUNE, Depuy Synthes, Warsaw, Indiana). The GR design allows smooth transition from knee extension to flexion by create a point of rotation similar to the “J curve” in the native knee, Fig. 1. The design rationale aimed to prevent the flexion instability by gradually change the center of femoral rotation to produce a more proper ligament tension throughout the arch of knee motion, whereas the posterior femoral roll-back was still preserved unlike the single-radius design [6].

Fig. 1
figure 1

Showed the sagittal femoral component between gradually reducing radius (GR) and multi-radius (MR) design

To increase the TKA outcome, modern knee prostheses are designed to match a native knee geometry, which anticipated to mimic the knee kinematic close to a normal knee [7, 8]. While, the strongest predictor of patient dissatisfaction after primary TKA was expectations not met [2], lack of clinical evidence for a GR modern knee prosthesis to inform patients preoperatively was a challenging. Therefore, this prospective study aims to explore any clinical significance between the gradually radius (GR) femoral component versus multi-radius (MR) femoral component in primary TKA.

Materials and methods

Trial design

The trial was a single-center, CONSORT-compliant, patient-blinded, 2-group, parallel randomized controlled trial (RCT) conducted in September 2020 as demonstrated in Fig. 2. The trial was prospectively approved by the Institutional Ethical Board Committee (ORT-2563–07,318); however, retrospective registration was approved on 30/10/2022, TCTR20221030001, due to COVID situation and human error. All participants gave written informed consent to the study inclusion and randomization before the enrollment.

Fig. 2
figure 2

CONSORT flow diagram depicting participant flow throughout the study, from eligibility through enrollment, intervention, and data collection

Setting and recruitment

Participants were recruited from an orthopedic outpatient clinic at Maharaj Nakorn Chiang Mai Hospital, Thailand, between September 2020 and August 2021. Patients were approached by the study coordinator during their attendance at the clinic following surgeon assessment for TKA and assessed for eligibility and willingness to participate. Eligible criteria included patients 50–80 years of age with a clinical and radiographic diagnosis of severe knee osteoarthritis (Kellgren and Lawrence grade IV) by one of the arthroplasty consultants and placed on the waiting list for unilateral TKA. Exclusion criteria were revision surgery, history of septic or inflammatory arthritis, body mass index (BMI) > 36 kg/m2, severe coronal deformity > 20° which would be potentially deleterious to postoperative outcome if the patient was randomized, and unable to ambulate independently preoperatively.

Randomization and blinding

Participants were randomly assigned into one of the two groups either GR or MR with a ratio of 1:1 using a computerized stratified block randomization sequence (block of 4). When a subject fulfilled all study criteria and was enrolled, allocation took place. Allocation concealment was performed using sequentially numbered, opaque, sealed envelopes (SNOSE) prepared by the independent person that was not relevant to this study. Participants also remained blinded to the type of prosthesis throughout the study. The two surgeons performing TKA were informed of participant assignment 1 month prior to surgery and had no role in patient assessment. The blinded study coordinator was accountable for gathering of outcome measures.

Interventions

All participants underwent TKA and postoperative care following the hospital’s routine TKA program, which has been standardized through the use of clinical pathway protocols. Demographic data of patients including age, sex, body mass index, length of stay, pre-operative range of motion and ASA were collected. All TKA designs were performed using a cruciate retaining (CR) prosthesis from two manufacturers; ATTUNE (Depuy Synthes, Warsaw, Indiana) as a GR group and LEGION (Smith & Nephew, Memphis, TN) as a MR group. Patients receive a spinal anesthesia with peripheral nerve block prior to surgery. All cemented TKAs were performed with the same technique by the same experience surgeons; SL and KK, under tourniquet control. A standard midline skin incision was used, and the arthrotomy was done using a medial parapatellar approach. The distal femoral cut was made with a valgus angle of 6° to the femur anatomical axis using an intramedullary cutting guide, while the proximal tibial cut was made perpendicular to the mechanical axis using an extramedullary guide. Femoral sizing was measured using femoral sizing jig with the anterior referencing technique before anterior, posterior, and chamfer bony cuts were completely removed. Femoral rotational alignment was performed according to the epicondylar axis, usually 3° of external rotation from the posterior condylar line. Posterior femoral osteophyte was routinely removed before the tibial surface preparation. A range of 7°-10° of posterior tibial slope was aimed along with the native tibial slope. Patella was selective resurfaced only patella mal-tracking and/or severe patellofemoral joint arthritis was found. All patients were scheduled for the 6- and 12-months follow-up with the study coordinator at the same clinic for clinical review.

Primary outcome

The primary outcome was the knee function at postoperative 6 and 12 months using the Knee injury and Osteoarthritis Outcome Score (KOOS) and the performance-based tests. The KOOS is a patient-reported outcome questionnaire to evaluate pain, symptom, activity daily living, sport, and quality of life after TKA. The performance-based tests used in this study were 30-s chair stand test (30CST), 40-m fast paced walk test (40FPWT), and 3-m timed up and go test (3TUG).

Secondary outcome

The secondary outcome was length of stay and range of motion at 6 and 12 months postoperatively. Pre and postoperative knee alignments were determined using hip knee axis (HKA) on weight-bearing scanogram. The component positions were evaluated by the mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), and tibial slope angle (TSA).

Statistical analysis

Prosthesis performance was evaluated by comparing change in the primary and secondary outcomes between two groups using SPSS 23.0 (IBM) at a level of significance of 0.05. We aimed to detect the minimum clinically important difference in the KOOS between groups, which the noninferiority margin was set at 15.1 points based on the previous study by Hung et al. [9]. The sample size calculation was based on an inferiority test with continuous outcome using a covariance adjusting for baseline scores, estimating between-patient standard deviations of 18.5 points [10], an alpha value = 0.05, and 2-sided test and power = 80%. A total of 20 participants per each group were required. We aimed to recruit 60 participants to allow for a 20% drop-out rate. This trial can end when the sample size and follow-up goal were reached. Continuous variables were assessed by independent t tests. Descriptive statistics are displayed as means with standard deviation or range for continuous variables.

Results

A total of 60 patients (male 20 and female 40) were enrolled and randomized for the TKA allocation; which was 30 patients in both GR and MR groups. No participant withdrawn during the follow-up. Data was completely collected in August 2022. At 6 months post TKA, three participants were unable to performed the 30CST due to dizziness, and at 12 months post TKA, one participant was unable to perform 3TUG test due to palpitation. Average patient age of GR group and MR group were 67 (59–82) and 69 (61–86) years, respectively. The characteristics of each group were similar at baseline (Table 1). The length of stay was not different between GR and MR group (5.93 ± 1.44 days vs 6.17 ± 1.86 days, p = 0.59).

Table 1 shows demographic data between gradually reducing radius (GR) versus multi-radius (MR) TKA groups

Outcomes

At 6 months and 12 months postoperatively, there was no significant difference between GR and MR group in all subscales of KOOS, Table 2. The changes of KOOS at 6 and 12 months from baseline showed clinical meaningful for both GR and MR group, Fig. 3. However, no statistical difference of the magnitude of KOOS change between 6 and 12 months from baseline was found between each group, Table 3. Performance-based tests were assessed from pre-operation and at 6 and 12 months post TKA. There was no significant difference between GR and MR group for 30CST, 40FPWT, and 3TUG, Table 4.

Table 2 showed the KOOS at baseline, 6 month and 12 months postoperatively
Fig. 3
figure 3

Showed KOOS score in symptom, pain, activities of daily living (ADL), sport and recreation function, and quality of life (QOL) between gradually reducing radius (GR) vs multi-radius (MR) femoral component TKA

Table 3 showed mean change in KOOS scores between GR and MR group at 6 and 12 months from baseline
Table 4 showed performance-based tests from preoperative TKA, 6 months post TKA, and 12 months post TKA

All patients in this trial had a genu varus and flexion contracture deformity with the HKA of 168° ± 5° and 168° ± 6° for GR and MR group (p = 0.8). There was no difference in post operative HKA between GR and MR group (176° ± 3° and 175° ± 3°, p = 0.38). Component positions between the two groups were not different as shown in Table 1. The mean baseline range of motion of GR group was 9.83°-77.17° (arc of motion 67.33° ± 10.56°), while the mean baseline range of motion of MR group was 7.5°-82.67° (arc of motion 75.17° ± 12.76°). At 6 months post TKA, a mean flexion angle of GR group was 91.5° ± 5.11° compared to 95.33° ± 9.55° for the MR group (p = 0.06). At 12 months post TKA, a mean flexion angle of GR group was 102.33° ± 8.17° compared to 99.67° ± 7.87° for the MR group (p = 0.2). Patients using GR design showed a greater improvement of knee motion after 6 months of TKA (22.5° ± 9.72° vs 19.5° ± 9.86°, p = 0.24); however, no statistical significance was detected. The change in degrees of knee motion after 12 months postoperatively was statistically significant greater for GR group compared to the MR group (34.67 ± 12.52 vs 23.67 ± 12.59, p = 0.001), Fig. 4.

Fig. 4
figure 4

Showed degrees of knee motions and degrees of motion gain after 6 and 12 months postoperatively between GR and MR group

Discussion

Cruciate retaining (CR) knee prosthesis has gained more popularity over a decade reported by most national joint registrations. The drawback of CR TKA is unpredictably paradoxical femoral anterior translation [11]. There are three designs of femoral component based on the knee rotation center. First, the MR femoral prosthesis was designed using the transepicondylar axis as an axis for knee flexion and rotation. Second, the single radius (SR) femoral prothesis was proposed as a theory of the knee flexion–extension rotation center is located more distal and posterior to the transepicondylar axis, leading to a longer extensor moment arm, maintaining stability during knee motion due to equal ligament tension during knee flexion and extension, and thereby reducing the paradoxical anterior femoral movement. Lou et al. [12] reported the SR prosthesis had a greater knee motion (123° ± 10° vs 115° ± 10°) and less anterior knee pain (7% vs 18%) compared to the MR prosthesis. However, no difference in terms of clinical scales, radiographic result, satisfaction rates, and survival results was observed between MR and SR [13, 14]. Third, the GR femoral prosthesis was also designed using the transepicondylar axis with the point of rotation similar to the native knee. The philosophy of GR design is made to enhance motion, function, and mid-flexion stability by avoid the abrupt changes in the femoral sagittal radius curvature [7]. The in vitro study by Clary CW et al. [7] presented the magnitude of paradoxical anterior translation in mid flexion movement was decreased between 21 and 68% for the GR design. In vivo kinematic study showed the lessor paradoxical anterior slide was found with the GR design [15]. Pfitzner et al. also reported GR design decreased femorotibial translation compared with conventional design and improved impact of load and muscle force in unloaded and weight-bearing conditions [16].

However, the clinical outcome for GR design is still controversial. Ranawat et al. reported no difference outcome and radiographic between Attune implant (GR design) and PFC TKA (MR design) at 2-year follow up [17]. Carey BW et al. [18], on the contrast, found a significant difference in clinical outcome at 6 months postoperatively between Attune and PFC sigma. Etter K et al. [19] also showed GR design was better than conventional design in terms of length of stay, operative time, and discharge status. Among inconclusive evidence, this is the first study with level of evidence I to investigate the clinical significance between GR and MR design. Our study showed that both GR and MR designs presented comparable results in terms of patient reported outcome; KOOS, and performance-based tests; 30CST, 40FPWT, and 3TUG at 6 and 12 months postoperatively between GR and MR designs of CR TKA. All patients whether GR or MR designs could return their performance outcomes to normal which are 30CST > 10 times [17], 40FPWT > 1 m/sec [20], and 3TUG < 13.5 s [21]. Although the trial was intended to assess the non-inferiority of GR as compared with MR designed prosthesis in terms of functional outcomes after TKA, the findings demonstrated that the range of motion can gain significantly greater in the GR design compared to the MR design at 12 months postoperatively (34.67 ± 12.52 vs 23.67 ± 12.59, p = 0.001). The limitations for this trial were associated conditions which affect participants’ mobility such as contralateral knee pain and associated spinal deformity were not excluded.

Conclusion

Both GR and MR cruciate retaining prostheses can lead to satisfactory outcomes at 6 and 12 months postoperatively. The GR prosthesis design gave more knee motions than did the MR prostheses. The GR prosthesis design is noninferior to the MR prosthesis design in terms of functional outcomes and performances.

Availability of data and materials

The datasets analyzed in this study are available from the corresponding author on reasonable request.

Change history

References

  1. Baker PN, van der Meulen JH, Lewsey J, Gregg PJ. The role of pain and function in determining patient satisfaction after total knee replacement. Data from the National Joint Registry for England and Wales The J of bone and joint surgBritish. 2007;89(7):893–900.

    CAS  Google Scholar 

  2. Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res. 2010;468(1):57–63.

    Article  PubMed  Google Scholar 

  3. White PB, Turcan S, Satalich JR, Ranawat AS, Ranawat CS. Clinical Outcomes of a Modern Total Knee Arthroplasty Prosthesis Compared to Its Predecessor at 5-Year Follow-Up: Matched Pair Analysis. J Arthroplasty. 2020;35(11):3150–5.

  4. Frankel VH, Burstein AH, Brooks DB. Biomechanics of internal derangement of the knee. Pathomechanics as determined by analysis of the instant centers of motion The Journal of bone and joint surgery American. 1971;53(5):945–62.

    CAS  Google Scholar 

  5. Kennedy JC, Fowler PJ. Medial and anterior instability of the knee. An anatomical and clinical study using stress machines The Journal of bone and joint surgery American. 1971;53(7):1257–70.

    CAS  Google Scholar 

  6. Ng JWG, Bloch BV, James PJ. Sagittal radius of curvature, trochlea design and ultracongruent insert in total knee arthroplasty. EFORT Open Rev. 2019;4(8):519–24.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Clary CW, Fitzpatrick CK, Maletsky LP, Rullkoetter PJ. The influence of total knee arthroplasty geometry on mid-flexion stability: an experimental and finite element study. J Biomech. 2013;46(7):1351–7.

    Article  PubMed  Google Scholar 

  8. Ushio T, Hamai S, Okazaki K, Gondo H, Ikebe S, Higaki H, Nakashima Y. Gradual-radius femoral component with s-curve post-cam provides stable kinematics at mid-flexion after total knee arthroplasty. J Orthop Sci. 2022;27(3):665–71.

    Article  PubMed  Google Scholar 

  9. Hung M, Bounsanga J, Voss MW, Saltzman CL. Establishing minimum clinically important difference values for the Patient-Reported Outcomes Measurement Information System Physical Function, hip disability and osteoarthritis outcome score for joint reconstruction, and knee injury and osteoarthritis outcome score for joint reconstruction in orthopaedics. World J Orthop. 2018;9(3):41–9.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Mencière ML, Epinette J-A, Gabrion A, Arnalsteen D, Mertl P. Does high flexion after total knee replacement really improve our patients’ quality of life at a short-term follow-up? Int Orthop. 2014;38(10):2079–86.

    Article  PubMed  Google Scholar 

  11. Victor J, Banks S, Bellemans J. Kinematics of posterior cruciate ligament-retaining and -substituting total knee arthroplasty: a prospective randomised outcome study. The Journal of bone and joint surgery British. 2005;87(5):646–55.

    Article  CAS  Google Scholar 

  12. Luo Z, Zhou K, Wang H, Pei F, Zhou Z. Comparison between Mid-Term Results of Total Knee Arthroplasty with Single-Radius versus Multiple-Radii Posterior-Stabilized Prostheses. J Knee Surg. 2022;35(2):204–14.

    Article  PubMed  Google Scholar 

  13. Luo Z, Luo Z, Wang H, Xiao Q, Pei F, Zhou Z. Long-term results of total knee arthroplasty with single-radius versus multi-radius posterior-stabilized prostheses. J Orthop Surg Res. 2019;14(1):139.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Liu S, Long H, Zhang Y, Ma B, Li Z. Meta-Analysis of Outcomes of a Single-Radius Versus Multi-Radius Femoral Design in Total Knee Arthroplasty. J Arthroplasty. 2016;31(3):646–54.

    Article  PubMed  Google Scholar 

  15. Takagi H, Asai S, Sato A, Maekawa M, Kawashima H, Kanzaki K. Case series report of navigation-based in vivo knee kinematics in total knee arthroplasty with a gradually reducing femoral radius design. Ann Med Surg (Lond). 2017;17:33–7.

    Article  PubMed  Google Scholar 

  16. Pfitzner T, Moewis P, Stein P, Boeth H, Trepczynski A, von Roth P, Duda GN. Modifications of femoral component design in multi-radius total knee arthroplasty lead to higher lateral posterior femoro-tibial translation. Knee Surg Sports Traumatol Arthrosc. 2018;26(6):1645–55.

    Article  PubMed  Google Scholar 

  17. Jones CJ, Rikli RE, Beam WC. A 30-s chair-stand test as a measure of lower body strength in community-residing older adults. Res Q Exerc Sport. 1999;70(2):113–9.

    Article  CAS  PubMed  Google Scholar 

  18. Carey BW, Harty J. A comparison of clinical- and patient-reported outcomes of the cemented ATTUNE and PFC sigma fixed bearing cruciate sacrificing knee systems in patients who underwent total knee replacement with both prostheses in opposite knees. J Orthop Surg Res. 2018;13(1):54.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Ranawat CS, White PB, West S, Ranawat AS. Clinical and Radiographic Results of Attune and PFC Sigma Knee Designs at 2-Year Follow-Up: A Prospective Matched-Pair Analysis. J Arthroplasty. 2017;32(2):431–6.

    Article  PubMed  Google Scholar 

  20. Bohannon RW. Comfortable and maximum walking speed of adults aged 20–79 years: reference values and determinants. Age Ageing. 1997;26(1):15–9.

    Article  CAS  PubMed  Google Scholar 

  21. Shumway-Cook A, Brauer S, Woollacott M. Predicting the probability for falls in community-dwelling older adults using the Timed Up & Go Test. Phys Ther. 2000;80(9):896–903.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

Concept and design: SL, KK, WJ; Study execution and data acquisition: SL and AC; Drafting of the manuscript: SL and AC; Critical revision of the manuscript and approval of the final manuscript: SL. All authors read and approved the final manuscript for submission.

Corresponding author

Correspondence to Sakkadech Limmahakhun.

Ethics declarations

Ethics approval and consent to participate

Ethic approval has been obtained from the Institutional Ethical Board Committee of Faculty of Medicine, Chiang Mai University, ORT-2563–07318. Written informed consent was obtained from participants. A statement to confirm that all methods were carried out in accordance with relevant guidelines and regulations.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

The original version of this article was revised: the authors corrected the error on the date of the trial from "conducted between January 2018—December 2020" to "conducted in September 2020".

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Limmahakhun, S., Chaiamporn, A., Klunklin, K. et al. Clinical advantages of gradually reducing radius versus multi-radius total knee arthroplasty: a noninferiority randomized trial. BMC Musculoskelet Disord 24, 69 (2023). https://doi.org/10.1186/s12891-023-06177-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12891-023-06177-4

Keywords