A simple method for restoring the femoral head center in hip arthroplasty: a 3-dimensional analysis in the Chinese population

Abstract

Background

Various authors have successfully demonstrated that the distance from the greater trochanter to the femoral head center (GTFHC) and the distance from the lesser trochanter to the femoral head center (LTFHC) can be used as parameters to determine the recovery of the femoral head center (FHC) during hip arthroplasty. It is necessary to undertake an anatomical study concerning the correlations between the greater trochanter (GT), the lesser trochanter (LT), and the FHC using data obtained from the 3D-CT reconstruction method.

Methods

The study comprised 293 patients (151 males and 142 females), with an average age of 65.06 years. The femoral head diameter(FHD), the linear distance from FHC to GT (GTFHC), and the linear distance from FHC to LT(LTFHC) were all measured and recorded data. The correlation between FHD with LTFHC and GTFHC was assessed using Pearson correlation coefficients, and the ratio of LTFHC and GTFHC to FHD was calculated from this ratio. All measured parameters were compared between the left and right sides and the sexes of the participants.

Results

The average ratios of GTFHC/FHD and LTFHC/FHD were 0.99 and 0.95, respectively .96% of the LTFHC had absolute lateral differences of < 4 mm . 92% of the GTFHC had absolute lateral differences of < 4 mm.

Conclusion

LTFHC and GTFHC are reliable reference parameters for preoperative planning and reconstruction of FHC of hip arthroplasty. The ratio displayed in this research may yield insight into a practical and straightforward method for orthopedic surgeons to perform hip arthroplasty in patients with femoral neck fractures. Ratios from studies based on the same race may be desirable for future work.

Peer Review reports

Introduction

With the progressive aging of the population, the incidence of hip fractures is increasing worldwide [1]. Hip arthroplasty is an effective therapy for treating femoral neck fractures, which can rapidly reconstruct hip function and avoid a series of complications such as infection and thrombosis caused by long-term bed rest, and can effectively reduce the morbidity and mortality rate while improving patients' quality of life [2].

The femoral head center (FHC) is biomechanically significant and is an important reference point for considering prosthesis placement in hip arthroplasty [3, 4]. The inappropriate position of the FHC after surgery can lead to complications such as altered lower limb force lines, uncoordinated gait, sciatica, and abduction weakness [5,6,7]. These complications can rapidly develop into unsatisfactory postoperative outcomes for patients.Therefore,accurate and reproducible identification of the FHC is necessary for the surgeon to restore normal hip biomechanics. As a result, the surgeon needs to be able to accurately and consistently identify the HJC in order to improve preoperative planning and restore normal hip kinematics.

Various authors have demonstrated that the linear distance from FHC to GT (GTFHC) and the linear distance from FHC to LT(LTFHC) can be successfully used as parameters for the recovery of the FHC in hip arthroplasty [8,9,10,11]. However, the majority of studies on the parameters of LTFHC are based on Western populations and not on Asian populations [8,9,10,11]. There are discrete variations between Asian and Western skeletons. To our knowledge, the study on parameter GTFHC was based on two-dimensional images(radiographs, which are susceptible to projection errors in the three-dimensional geometry of the proximal femur), which is potentially reduced in 3D scans. And few studies have investigated parametric LTFHC in Chinese populations. And Under this rationale, it is necessary to perform an anatomical study of the correlations between the GT, the LT, and the FHC in the Chinese population based on the method of 3D-CT reconstruction. This study aimed to: (1) establish a left–right difference analysis of LTFHC and GTFHC. (2) investigate the correlation between the GT, the LT, and the FHC in the Chinese population. (3) compare the differences between our study and the earlier research.

Patients and methods

This study was approved by the Ethics Committee of the Second Hospital of Shanxi Medical University.

Participants

This study selected 293 CT images of patients attending the Second Hospital of Shanxi Medical University from January 2020 to January 2022. 151 males and 142 females participated in this study, with a mean age of 65.06 years. Participants’ minimum and maximum ages were 21 and 95, respectively.

Inclusion criteria

  1. (1)

    patients were ≥ 20 years of age; (2) complete bilateral hip CT data were available.

Exclusion criteria

  • (1) advanced degenerative changes of the hip; (2) history of rheumatic immune system diseases; (3) previous surgical history, bone disease (metabolic disease or malignancy), or trauma of the lower extremity (4) developmental dysplasia of the hip; (5) morphology of the greater trochanter is flat or false double apical; (6) poorly documented individuals.

Imaging procedures

The equipment used to collect the data was a German Siemens 64-row double spiral CT from the imaging department of the Second Hospital of Shanxi Medical University. The patients were scanned electronically by computed tomography. Scanning conditions included a scan voltage of 120 kV, current of 210 mAs, a layer thickness of 0.699 mm, window width of 2500 Hu, bed position of 100 Hu, and a scan matrix of 512 × 512. Image processing was performed with MIMICS 20.0 and 3-Matic 9.0 (Materialise’s Interactive Medical lmage Control System, Materialise*, Materialise HQ) software.

3D reconstruction

The DICOM images were imported into Mimics 20.0 software (Materialise, Belgium) for the following, tuning contrast, threshold setting, region growing functionality, and 3D reconstruction to generate the 3D models.

Identification of Bony Landmarks

In three dimensions, the point chosen to represent the LT was identified. This position was chosen in the proximal–distal and mediolateral directions, at the intersection of the proximal aspect of the LT with the proximal femoral metaphysis. The point is located at the center of this junction in the anteroposterior direction.

A single sphere containing at least 80% of the entire subchondral surface of the femoral head is then selected and used as the basis for calculating the best-fit individual spheres. The point represents FHC is the geometric center of this sphere.

The point represents GT is the the apex of the greater trochanter.

3D Measurement

The 3D model is imported into 3-Matic research 11.0 (Materialise, Belgium) for 3D measurement. The femoral head diameter(FHD), the linear distance from FHC to GT (GTFHC), and the linear distance from FHC to LT (LTFHC) were all measured and recorded, as shown in Fig. 1. We randomly selected 50 samples to measure all parameters twice at an interval of 5 days by two observers to determine intra- and inter-observer measurement reliability.

Fig. 1
figure 1

FHD, femoral head diameter; LT, lesser trochanter; LTFHC, linear distance from the FHC to the LT; GT, greater trochanter; GTFHC, linear distance from the FHC to the GT

Statistics

Intra-and inter-observer measurement reliabilities were analyzed using intraclass correlation coefficient (ICC).The mean and standard deviation (SDS) of all parameters were determined, and the data were tested for normality using the Kolmogorov–Smirnov test. All comparisons between genders were performed using two independent samples. These tests were the t-test (normally distributed parameters) or the Mann–Whitney U-test (non-normally distributed parameters). A two-tailed paired t-test was applied to assess the variation between the left and right sides. Following this, Pearson correlation coefficient and linear regression analyses were used to evaluate and identify the correlation of FHD with GTFHC and LTFHC. Statistical analysis was performed using IBM SPSS Statistics 23.0 (IBM, Armonk, NY, USA).

Results

Intra-observer and inter-observer variability

All ICC values were above 0.91, indicating a very high intra- and inter-observer reliability (Table 1).

Table 1 Intra- and inter-observer reliability

Measured distance

The mean FHD was 47.26 ± 3.41 mm, the distance LTFHC was 45.08 ± 4.11 mm, and the distance GTFHC was 46.83 ± 4.34 mm. The mean LTFHC/FHD was 0.95 ± 0.06, with a correlation coefficient (r) of 0.650 (p < 0.01). The mean GTFHC/FHD was 0.99 ± 0.07, with a correlation coefficient (r) of 0.655 (p < 0.01), as shown in Table 2.

Comparison between left and right sides

The mean absolute value of the lateral difference for LTFHC was 1.41 ± 1.18 mm, the mean lateral difference for LTFHC was 0.09 ± 1.83 mm with a correlation coefficient of r = 0.90 (p < 0.01). The mean absolute value of the lateral difference for GTFHC was 1.81 ± 1.41 mm, the mean lateral difference for GTFHC was 0.17 ± 2.29 mm with a correlation coefficient of r = 0.861 (p < 0.01). Overall, 76% of the LTFHC had absolute lateral differences of < 2 mm, where 20% of the LTFHC were between 2 and 4 mm, and 4% of the LTFHC were > 4 mm. 63% of the GTFHC had absolute lateral differences of < 2 mm, 29% of the GTFHC were between 2 and 4 mm, and 8% of the GTFHC were > 4 mm. Further information regarding differences between the left and right sides of the femoral anatomy is listed in Table 3.

Table 2 Measurement results and differences between males and females

Comparison between males and females

The mean FHD was 49.71 ± 2.71 mm in males and 46.88 ± 3.30 mm in females; the mean FHD was 6% higher in the male population than in the female population. LTFHC/FHD was 0.94 ± 0.07 in males and 0.96 ± 0.07 in females. GTFHC/FHD was 0.98 ± 0.07 in males and 1.00 ± 0.07 in females, and the difference between the male and female populations was determined to be statistically significant. Additional information regarding the gender differences in femoral anatomy is listed in Table 2.

Table 3 Measurement differences between left and right sides

Pearson correlation coefficient and linear regression analysis

The relationship between LTFHC and FHD for males being R = 0.497, P ≤ 0.001 and LTFHC = 0.77FHD + 8.48 and for females the results were R = 0.552, P < 0.001 and LTFHC = 0.91 FHD + 2.65, respectively. The relationship between GTFHC and FHD for males was R = 0.521, P ≤ 0.001 and GTFHC = 0.82FHD + 7.90 and for females, R = 0.494, P < 0.001 and GTFHC = 0.86FHD + 6.12,respectively, as shown in Fig. 2.

Fig. 2
figure 2

Correlation between FHD and the LTFHC、GTFHC when males and females are considered individually

Differences between this study and the previous literature

We compared our study with other studies regarding inclusion population, measurement technique, sample size, ratio, and error values (Tables 4 and 5; Figs. 3 and 4). Applying the Hasler et al. rate to the study population, the mean difference in LTFHC was 8.59 mm. Applying the rates of Wang (2021) to the study population, the mean differences in LTFHC and GTFHC were 5.46 and 4.10 mm, respectively. Using the ratios proposed in this study, the mean differences in LTFHC and GTFHC were 2.46 mm and 2.66 mm, respectively, as summarised in Table 5.

Table 4 Overview of Literature Regarding the LTFHC and GTFHC
Table 5 Differences in ratios and estimated values between this study and the previous literature
Fig. 3
figure 3

Frequencies of categorized differences between predicted and measured values of LTFHC and GTFHC applying the ratios described by different authors on the total study population (n = 294)

Fig. 4
figure 4

Standard deviation of the differences between predicted and measured values of of LTFHC and GTFHC applying the ratios described by different authors on the total study population (n = 294)

Discussion

The improper rotation of the femoral head center is one of the typical complications observed with hip arthroplasty [13, 14], which often results in changes to hip biomechanics, gait abnormalities, lower back pain, sciatica, joint instability, and an increased risk of dislocation [2, 15], thus adversely affecting the subjective perception of the patient and the recovery and restoration of clinical function after hip arthroplasty. As a result, orthopedic surgeons are constantly investigating methods to restore the proper position of the FHC. Kumar et al. [16] found that placing the same vertical distance from the FHC to the apex of the greater trochanter on the healthy side could restore the HJC [16]. However, due to the limited exposure of the proximal femur, it is difficult to determine the vertical orientation during surgery.

Different authors have demonstrated that LTFHC and GTFHC can be used as parameters for the recovery of the FHC during surgery. Polishchuk et al. investigated the effects of demographic parameters such as sex, race, weight, and age on the parameter LTFHC [17]. They developed a formula based on multivariate regression that was somewhat complicated. Hasler et al.[18]found a mean ratio of 1.16 between LTFHC and FHD by measuring 3D CT data in the Western population [18]. Wang et al. analyzed the results of 100 Chinese adult pelvic orthopantomographs. They found that the ratio of LTFHC to FHD was approximately 0.84, and the ratio of GTFHC to FHD was approximately 0.92 [11].

We found that the mean ratios of GTFHC/FHD and LTFHC/FHD in the Chinese population, as measured by 3D CT scanning, were 0.99 and 0.95, respectively. These ratios are slightly higher than the value measured by Wang et al. likely because our measurements were based on 3D CT imaging. In contrast, the measurements of Wang et al. were based on 2D images (anteroposterior radiographs) and are susceptible to projection errors in the 3D geometry of the proximal femur [19, 20]. Haleret et al. measured femur models in Western populations by 3D CT imaging and recorded results with relatively higher ratios than this study, suggesting a difference between Chinese and Western populations.

The surgeon’s assessment of soft tissue tension during hip arthroplasty in patients determines leg length after placement of a trial prosthesis [21]. On the other hand, soft tissue tension is affected by various factors, including muscle mass and the amount of anesthetic utilized [22]. The FHD is the anatomical parameter of the proximal femur that is unaffected by a femoral neck fracture. In hip arthroplasty for patients with femoral neck fractures, the FHD is not altered by the femoral neck fracture. By multiplying the FHD with a particular ratio, LTFHC and GTFHC can be determined.

Although preoperative planning of hip replacement using the contralateral side is common [23,24,25], the lateral discrepancies in the 3-dimensional geometry of the proximal femur may generate inaccuracies in various template approaches [26,27,28]. There are limited data on the lateral variability of LTFHC and GTFHC [18]. Understanding the normal variation in these parameters may improve the accuracy of preoperative planning for hip arthroplasty. Our study found that the absolute LTFHC lateral difference in our population was 1.41 ± 1.18 mm, the mean LTFHC lateral difference was 0.09 ± 1.83 mm with a correlation coefficient of r = 0.90 (P < ;0.01).The mean absolute value of the lateral difference for GTFHC was 1.81 ± 1.41 mm, the mean GTFHC lateral difference was 0.17 ± 2.29 mm with a correlation coefficient of r = 0.861 (p < 0.01). Overall, 96% of LTFHC had an absolute lateral difference < 5 mm, 94% of the GTFHC had absolute lateral differences of < 5 mm. The differences between the two sides were small. They may not produce clinical symptoms because of the resulting template, and most smaller LLD or FO inequalities after hip arthroplasty have no or few symptoms. Therefore, the healthy-side LTFHC and GTFHC are reliable reference parameters for preoperative template and intraoperative validation of hip arthroplasty.

Sarint et al. [29] emphasized the importance of pelvic body position in measuring the FO distance and bilateral lower limb length [29]. In this study,the GTFHC and the LTFHC,were selected as the parameters for restoring FHC, which theoretically reduced the measurement error caused by the difference between the femoral and pelvic body positions.

The work in this study represents the first time that the parameter GTFHC has been investigated in 3 dimensions. It is also the first time the parameter LTFHC has been investigated in a sufficiently large sample of the Chinese population.We analyzed the the relative position of the femoral head center, greater trochanter, and lesser trochanter based on 3D-CT image reconstruction.. These data could provide a reference for restoring FHC during hip arthroplasty for hip fracture, especially in the absence of a contralateral hip reference.

However, this study does have limitations:

  • 1. Articular cartilage was not included in creating the 3D model of the femur because a CT scan was used. The thickness of the femoral cartilage varies from patient to patient. There may be an effect on the femoral head diameter measurement in the results.In further studies, it may be more accurate to measure the results using MRI scan data.

  • 2. The position of the LT on the proximal femur’s surface elevation is relatively unaffected by the anatomy of the proximal femoral diaphysis and the end of the diaphysis. It is positioned medial to the femoral stem from almost posterior to distally superior [30]. Some inaccuracies are expected due to the anterior, posterior, and medial portions of the lesser trochanteric position to the LTFHC distance.

  • 3. The greater trochanter’s shape is quite variable [31], and the introduction of some measurement errors is anticipated. Based on the relative position of the apex of the greater trochanter to the median axis of the femoral medullary,the greater trochanter can be classified into five types:: anterior leaning, posterior leaning, centred and flat. A few greater trochanters had an additional, far-anterior protrusion that resulted in a false double apical appearance.The anterior leaning, posterior leaning and centred greater trochanter apexes are easier to identify and account for more than 80% of cases [31].For the flat and false double apical types, we did not measure because the greater trochanteric apex was not easy to confirm.

  • 4. There are only Chinese hip data available. As a result, a cross-sectional investigation using 3D CT scans of asymptomatic persons of various races will be required. As Japanese and Koreans have comparable body types to Chinese people, the findings of this study may be useful for patients and researchers in these nations.

Conclusion

We conclude that the greater trochanter and the lesser trochanter can be used as reliable landmarks to precisely locate the FHC. LTFHC and GTFHC are reliable reference parameters for preoperative template and intraoperative verification of hip arthroplasty.The ratio displayed in this research may provide a practical and simple method for orthopedic surgeons to perform hip arthroplasty in patients with femoral neck fractures. Furthermore, ratios from studies based on the same race may be preferable. These data could provide a reference for restoring FHC during hip arthroplasty for hip fracture, especially in the absence of a contralateral hip reference.

LTFHC and GTFHC are reliable reference parameters for preoperative planning and reconstruction of FHC of hip arthroplasty.

Availability of data and materials

The datasets generated and/or analyzed during the current study are not publicly available due to limitations of ethical approval involving the patient data and anonymity but are available from the corresponding author on reasonable request.

References

  1. Wang G, Guo A, Yu F, et al. A simple method to minimize leg length discrepancy in hip hemiarthroplasty. Clin Interv Aging. 2019;14:1601–5.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Desai AS, Dramis A, Board TN. Leg length discrepancy after total hip arthroplasty: a review of literature. Curr Rev Musculoskelet Med. 2013;6(4):336–41.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Debbi EM, Rajaee SS, Mayeda BF, Penenberg BL. Determining and achieving target limb length and offset in total hip arthroplasty using intraoperative digital radiography. J Arthroplasty. 2020;35(3):779–85.

    Article  PubMed  Google Scholar 

  4. Clement ND, S Patrick-Patel R, MacDonald D, Breusch SJ. Total hip replacement: increasing femoral offset improves functional outcome. Arch Orthop Trauma Surg. 2016;136(9):1317–23.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  5. Rasheed A, Shaukat MK, Alam F. Mean limb length discrepancy after total hip arthroplasty. J Ayub Med Coll Abbottabad. 2020;32(Suppl 1)(4):S651–4.

    Google Scholar 

  6. Zhao JX, Su XY, Zhao Z, Xiao RX, Zhang LC, Tang PF. Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review. Ann Transl Med. 2020;8(4):130.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Kurtz WB, Ecker TM, Reichmann WM, Murphy SB. Factors affecting bony impingement in hip arthroplasty. J Arthroplasty. 2010;25(4):624-34.e1-2.

    Article  PubMed  Google Scholar 

  8. Polishchuk DL, Patrick DA Jr, Gvozdyev BV, Lee JH, Geller JA, Macaulay W. Predicting femoral head diameter and lesser trochanter to center of femoral head distance: a novel method of templating hip hemiarthroplasty. J Arthroplasty. 2013;28(9):1603–7.

    Article  PubMed  Google Scholar 

  9. Unnanuntana A, Toogood P, Hart D, Cooperman D, Grant RE. Evaluation of proximal femoral geometry using digital photographs. J Orthop Res. 2010;28(11):1399–404.

    Article  PubMed  Google Scholar 

  10. Boymans T, Veldman HD, Grimm BP, Noble PC, Heyligers IC. Femoral head size is correlated with head position in very elderly patients. J Arthroplasty. 2017;32(2):587–93.

    Article  PubMed  Google Scholar 

  11. Wang G, Guo A, Zhang Y, et al. Measurement of the relative position of the femoral head center, greater trochanter, and lesser trochanter. Ann Palliat Med. 2021;10(11):11524–8.

    Article  PubMed  Google Scholar 

  12. Unnanuntana A, Toogood P, Hart D, Cooperman D, Grant RE. The evaluation of two references for restoring proximal femoral anatomy during total hip arthroplasty. Clin Anat. 2010;23(3):312–8.

    PubMed  Google Scholar 

  13. Hofmann AA, Skrzynski MC. Leg-length inequality and nerve palsy in total hip arthroplasty: a lawyer awaits. Orthopedics. 2000;23(9):943–4.

    Article  PubMed  CAS  Google Scholar 

  14. Dong N, Yang C, Li SQ, Gao YH, Liu JG, Qi X. Effect of Preoperative leg length discrepancy on functional outcome and patient satisfaction after total hip arthroplasty in cases of osteonecrosis of the femoral head. J Arthroplasty. 2016;31(12):2789–94.

    Article  PubMed  Google Scholar 

  15. Li J, McWilliams AB, Jin Z, et al. Unilateral total hip replacement patients with symptomatic leg length inequality have abnormal hip biomechanics during walking. Clin Biomech (Bristol, Avon). 2015;30(5):513–9.

    Article  Google Scholar 

  16. Kumar A, Passey J, Kumar M, Chouhan D, Saini M, Das S. Reliability of relation between greater trochanter and center of rotation of femoral head in Indian population. J Clin Orthop Trauma. 2020;11(Suppl 4):S522–5.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Panichkul P, Pinsornsak P. Radiographic measurement to restore femoral head center in hip arthroplasty. J Med Assoc Thai. 2012;95(Suppl 10):S32–6.

    PubMed  Google Scholar 

  18. Hasler J, Hoch A, Fürnstahl P, Ackermann J, Zingg PO, Vlachopoulos L. Is the contralateral lesser trochanter a reliable reference for planning of total hip arthroplasty - a 3-dimensional analysis. BMC Musculoskelet Disord. 2021;22(1):268.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Sariali E, Mauprivez R, Khiami F, Pascal-Mousselard H, Catonné Y. Accuracy of the preoperative planning for cementless total hip arthroplasty. A randomised comparison between three-dimensional computerised planning and conventional templating. Orthop Traumatol Surg Res. 2012;98(2):151–8.

    Article  PubMed  CAS  Google Scholar 

  20. Lechler P, Frink M, Gulati A, et al. The influence of hip rotation on femoral offset in plain radiographs. Acta Orthop. 2014;85(4):389–95.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Naito M, Ogata K, Asayama I. Intraoperative limb length measurement in total hip arthroplasty. Int Orthop. 1999;23(1):31–3.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  22. Sathappan SS, Ginat D, Patel V, Walsh M, Jaffe WL, Di Cesare PE. Effect of anesthesia type on limb length discrepancy after total hip arthroplasty. J Arthroplasty. 2008;23(2):203–9.

    Article  PubMed  Google Scholar 

  23. González Della Valle A, Slullitel G, Piccaluga F, Salvati EA. The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty. 2005;20(1):51–8.

    Article  PubMed  Google Scholar 

  24. Scheerlinck T. Primary hip arthroplasty templating on standard radiographs. A stepwise approach. Acta Orthop Belg. 2010;76(4):432–42.

    PubMed  Google Scholar 

  25. Meermans G, Malik A, Witt J, Haddad F. Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty. Clin Orthop Relat Res. 2011;469(6):1677–82.

    Article  PubMed  Google Scholar 

  26. Dimitriou D, Tsai TY, Yue B, Rubash HE, Kwon YM, Li G. Side-to-side variation in normal femoral morphology: 3D CT analysis of 122 femurs. Orthop Traumatol Surg Res. 2016;102(1):91–7.

    Article  PubMed  CAS  Google Scholar 

  27. Young EY, Gebhart J, Cooperman D, Ahn NU. Are the left and right proximal femurs symmetric. Clin Orthop Relat Res. 2013;471(5):1593–601.

    Article  PubMed  Google Scholar 

  28. Lindner C, Wallis GA, Cootes TF. Increasing shape modelling accuracy by adjusting for subject positioning: an application to the analysis of radiographic proximal femur symmetry using data from the Osteoarthritis Initiative. Bone. 2014;61(100):64–70.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  29. Sarin VK, Pratt WR, Bradley GW. Accurate femur repositioning is critical during intraoperative total hip arthroplasty length and offset assessment. J Arthroplasty. 2005;20(7):887–91.

    Article  PubMed  Google Scholar 

  30. Gómez-Hoyos J, Schröder R, Palmer IJ, Reddy M, Khoury A, Martin HD. Iliopsoas tendon insertion footprint with surgical implications in lesser trochanterplasty for treating ischiofemoral impingement: an anatomic study. J Hip Preserv Surg. 2015;2(4):385–91.

    PubMed  PubMed Central  Google Scholar 

  31. Farhang K, Desai R, Wilber JH, Cooperman DR, Liu RW. An anatomical study of the entry point in the greater trochanter for intramedullary nailing. Bone Joint J. 2014;96-B(9):1274–81.

    Article  PubMed  CAS  Google Scholar 

Download references

Acknowledgements

Not applicable

Funding

This work was supported by the National Natural Science Foundation of China (No. 81972075).

Author information

Authors and Affiliations

Authors

Contributions

TZ, WZH, YZW, GZJ and GZ contributed to data collection, analysis, and writing of the manuscript. TZ, MXJ, GZZ, CBH, XC contributed to the study design and writing of the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Chuan Xiang.

Ethics declarations

Ethics approval and consent to participate

This study was approved by the Ethics Committee of the Second Hospital of Shanxi Medical University.In addition to this, we confirm that all methods were performed in accordance with the relevant guidelines and regulations. We wrote it based on a retrospective study, using DICOM data, which is why we requested waived informed consent. As for informed consent, "Informed consent waiver" obtained from the Ethics Committee of the Second Hospital of Shanxi Medical.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tian, Z., Mao, X., Gao, Z. et al. A simple method for restoring the femoral head center in hip arthroplasty: a 3-dimensional analysis in the Chinese population. BMC Musculoskelet Disord 23, 986 (2022). https://doi.org/10.1186/s12891-022-05901-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12891-022-05901-w

Keywords