Skip to main content

Comparative analysis of the biomechanics of anterior cervical discectomy and fusion with multiple segmental plates fixation versus single multilevel plate fixation: a finite element study

Abstract

Background

This study aimed to compare the biomechanical differences between anterior cervical discectomy and fusion (ACDF) with multiple-level separate plates and conventional long plates by using finite element analysis.

Methods

The following four finite element models were created to simulate various fixations: (1) C4–6 ACDF with multiple plates, (2) C4–6 ACDF with a single plate, (3) C3–6 ACDF with multiple plates, and (4) C3–6 ACDF with a single plate. The maximum Von-mises stress of the cage and fixation, compressive force of the adjacent intervertebral discs and range of motion (ROM) of different segments in the four models were calculated and analyzed.

Results

For C4–6 ACDF, the maximum Von-mises stress of the cage and fixation was lower in the multiple plate fixation model in all motion states. Similarly, for the C3–6 ACDF models, the peak stress of the C3–4 and C5–6 cages was lower with multiple plates fixation in all motions but the stress of the C4–5 cage in the multiple plates model was slightly higher in flexion, bending and rotation. Besides, applying multiple plates in C3–6 ACDF models resulted in a decreased maximum stress of the fixation under different motions except for bending. In both the C4–6 ACDF and C3–6 ACDF models, the ROM values of the adjacent motion segments were lower in the multiple plates models in extension, bending and rotation. In the C4–6 ACDF models, the peak stress on the adjacent intervertebral discs in the multiple plates models was slightly smaller. In C3–6 ACDF models, the maximum stress on the adjacent intervertebral discs was larger in the single-plate model under flexion, bending and rotation movements.

Conclusion

Multiple plates fixation has a positive effect on increasing stiffness and maintaining the ROM of adjacent segments, indicating lower risk of construct failure and adjacent segment degeneration. Further studies are required to confirm its efficacy in clinical practice.

Peer Review reports

Background

Anterior cervical discectomy and fusion (ACDF) is a well-established and effective treatment for symptomatic cervical myelopathy and radiculopathy [1, 2]. However, there are issues with ACDF, particularly for multilevel ACDF [3]. An important complication is adjacent segment degeneration (ASD), which may be caused by abnormal range of motion (ROM) of the segment adjacent to the fusion level [4, 5]. Previous studies have reported an increased rate of ASD in patients with multilevel ACDF compared to that in patients with single-level ACDF [3, 6]. The result might be associated with the abnormal load distribution on the cervical spine after multilevel ACDF due to the long plate applied in the surgery [7]. Furthermore, the load sharing and transfer of stresses through these long plates to the adjacent segments might increase the risk of other complications, including construct failure, misalignment, nonunion or pseudarthrosis [8, 9]. The prominence of the long plates could also affect the surrounding tissue, causing persistent postoperative dysphagia or even esophageal injury [10, 11].

Recently, the application of separate segmental fixation for multilevel ACDF such as zero-profile spacer has been suggested by some researchers [12, 13]. It is reported that use of multiple single-level fixation possesses some biomechanical advantages such as lower risk of ASD compared to multilevel long fixation [12]. Moreover, the separate segmental fixation might be beneficial with regards to decreasing the complication associated with injury of the surrounding tissue caused by the long plate such as post-operative dysphagia [13, 14].

Previous researches have primarily focused on the biomechanical performance of zero-profile spacers, however, ACDF with multiple separate plates is a noteworthy schedule for separate segmental fixation due to decreased subsidence and better improvement in cervical lordosis when compared with zero-profile spacers [15, 16]. To best of our knowledge, few studies reported the biomechanical comparison between the fixation with multiple separate plates and with a single long plate [17, 18]. Finn et al. compared the biomechanical efficacy of applying two-level noncontiguous plates or three-level plate for patients with two noncontiguous levels requiring treatment, but their study focused on the forces exerted on the intermediate and adjacent levels [17]. Rios and Eastlack studied the stiffness of multiple segmental plates using fatigue testing. Both studies were based on cadaveric specimens and focused on three-level fusion [18]. The current study applied finite element (FE) analysis, which has been widely applied in research of spinal biomechanics to simulate the complicated construct and allows calculation of relevant values [19]. The abovementioned advantages enabled us to perform more biomechanical evaluations on both two-level and three-level fusions. The aim of this study was to compare the biomechanical differences regarding the ROM and stress of the cage, fixation and adjacent discs between ACDF with multiple-level separate plates and with continuous long plates using FE analysis.

Methods

Establishment of the intact cervical model

Computed tomography (CT) images of a 27-year-old male subject without a history of cervical spine disease were collected from the Department of Radiology at our hospital. This study was approved by the Institutional Review Board of our hospital. The slice thickness was 0.625 mm, and the images from C2 to C7 were exported as the Digital Imaging and Communications in Medicine format. The images were then imported into Mimics software to generate a three-dimensional model. Subsequently, the three-dimensional model was imported into Geomagic Studio 2013 (3D Systems, Inc., Rock Hill, South Carolina, USA) for further modification, including polishing and mesh. The ‘Construct Patches’ and ‘Grid and Fit Surfaces’ tools were applied during the procedure and the modified model was subsequently exported as stereolithography (STL) format. The STL file was imported into SolidWorks 2017 computer-aided design software (Dassault Systèmes SolidWorks Corporation, Waltham, Massachusetts, USA). The cortical bone, cancellous bone, endplate, annulus fibrosus, nucleus pulposus, articular cartilage, and other elements were created based on previous literature [20]. An cervical spine model of C2-C7 was created with all the elements mentioned above. The model created in SolidWorks 2017 CAD was imported into the ANSYS Workbench 2020 software for mesh and calculation (ANSYS, Ltd., Canonsburg, Pennsylvania, USA). The detailed parameters of the cortical bone, cancellous bone, endplates, annulus fibrosus, nucleus pulposus and other properties were defined based on previous studies and are listed in Table 1 [12, 19]. Given that the ligaments generally did not result in obvious resistance force against the physiological compression, the ligaments were set as ‘tension only’ spring element to simulate this feature and the biomechanical parameters were set as Table 2 showed [19].

Table 1 Mechanical parameters of applied component
Table 2 Ligaments force-displacement behavior (F: N, dl: mm)

Boundary and loading conditions

Previous studies were referenced to set the boundary and loading conditions for biomechanical testing [21,22,23,24]. The contact type between the screws, plates, and vertebrae was set as the connection mode [23, 24]. Nodes of the inferior surface of the C7 vertebra were constrained. The type of contact between the intervertebral discs and adjacent endplates was defined as the bonded mode. The contact type of the facet joint was set as frictional and the friction coefficient was 0.1 [21, 22]. The frictionless contact type was set between the cancellous bone filling the cage and the vertebra. The ‘bonded mode’ contact type was applied between the cage and the vertebra.

Subsequently, a follower load of 73.6 N combined with 1.0 N·m bending moments of flexion, extension, lateral bending, and axial rotation were applied on the superior surface of the C2 vertebra to simulate spinal motions [25, 26]. The ROM of the model was recorded and compared with previous studies for validation of the model [27, 28].

Surgical simulation

Models of the plates, cages and screws applied in the current study were created in SolidWorks 2017 CAD. The cages were 14 mm length, 12 mm width, and 6 mm height. The screws used were 14 mm long and 4 mm in outer diameter. The length of the plates used in the experiment was selected with 14 mm width and 2.5 mm thickness. The annulus fibrosus, nucleus pulposus, endplates and anterior longitudinal ligament were removed at the surgical segments. To simulate the clinical strategy of preventing ASD, plates were installed to enable the plate ends to be inferior to one-third of the superior vertebrae or superior to one-third of the inferior vertebrae along the disc. Four models of the cervical spine with various fixations were constructed in the current study. The models included: (1) C4–6 ACDF with segmental plate fixation (C4–6 multiple plates model); (2) C4–6 ACDF with long plate fixation (C4–6 single plate model); (3) C3–6 ACDF with segmental plate fixation (C3–6 multiple plates model); and (4) C3–6 ACDF with long plate fixation (C3–6 single plate model). The schemes for the different fixations are shown in Fig. 1.

Fig. 1
figure 1

Scheme of various fixation constructs created in the study. A C4–6 ACDF with segmental plate fixation model (C4–6 multiple plates model); B C4–6 ACDF with long plate fixation model (C4–6 single plate model); C C3–6 ACDF with segmental plate fixation model (C3–6 multiple plates model); D C3–6 ACDF with long plate fixation model (C3–6 single plate model). MP = multiple plates SP = single plates

Data collection

Combining the created models with a 73.6 N follower load and 1.0 N·m bending moments of different motions, the calculation was performed. Several parameters were recorded to evaluate the biomechanical performance of the various fixation plans as follows: (1) the maximum Von-mises stress of the cage,(2) the maximum Von-mises stress of the plates and screws, (3) the compressive force of the adjacent intervertebral discs (IVD), and (4) the ROM of the spine segment from C2–7. For the bending and rotation movements, the acquired data for the left and right bending/rotation were averaged in this study. The mesh convergence test was performed during the procedures concerning the Von-mises stress to decrease potential errors caused by the mesh size. The areas where the stress was concentrated were checked and the element sizes of the areas were altered and refined. With increasing mesh size, the results that showed an almost stable solution with a variability of less than 5% were recognized as acceptable and recorded in this study.

Results

Model validation

For validation, the ROM of the intact model was compared with that of previous studies [27]. The ROM of the intact C2–7 model in various motion states was listed in Table 3 and was close to that of previous biomechanical studies, as shown in Fig. 2 [27, 28].

Table 3 The range of motion of the intact cervical spine at different segments (°)
Fig. 2
figure 2

Model Validation

Loading of the cage and fixation

The maximum Von-mises stress of the cage is presented in Table 4 and Fig. 3. As the figure shows, for the C4–6 ACDF models, the maximum stress of both cages in the C4–6 multiple plates model was lower in the multiple plate fixation model than in the single plate model in all motion states. Similarly, for the C3–6 ACDF models, the peak stress of the C3–4 and C5–6 cages was lower with the multiple plates fixation in all motions. However, the stress of the C4–5 cage in the multiple plates model was slightly higher than that of the single plate model in flexion, bending and rotation.

Table 4 The maximum Von-mises stress of the cage (MPa)
Fig. 3
figure 3

The maximum Von-mises tress of the cage. MP = multiple plates SP = single plates

As Fig. 4 presents, the maximum loading of the plates and screws in the C4–6 ACDF models resembles the stress of the cage (Table 5). The multiple plates model afforded a lower peak stress than the single model in all motion states. In the C3–6 ACDF models, applying multiple plates led to lower maximum stress of the fixation under different simulation motions except for the bending movement.

Fig. 4
figure 4

The maximum loading of the plates and screws. MP = multiple plates SP = single plates

Table 5 The maximum loading of the plates and screws (MPa)

ROM of different segment

Tables 6, 7 and Fig. 5 present the values and percentages of ROM for the different cervical segments from C2–7. Given that the ROM values of the fused levels were almost zero, the total ROM values of both models decreased but the unfused segments increased to some extent in all ACDF models compared to the intact cervical spine model. It could be noted that no obvious divergence between the multiple plates fixation and single plate fixation could be found regarding the percentage of ROM in both C4–6 and C3–6 ACDF models in various motion states. However, the ROM values differ, especially in the bending and rotation states. For both C4–6 ACDF and C3–6 ACDF models, in the extension, bending and rotation conditions, the ROM values of the superior and inferior adjacent motion segments were lower in the multiple plates models. To be more detailed, Fig. 6 and Table 8 present the increase of ROM of different segments in various motion states for the models involved in the study. For C4–6 fusion surgery, the increase in ROM ranged between 4% and 19% in multiple plates fixation models and between 2 and 22% in single plates fixation models. During flexion, the ROM increase of C2–3, C3–4, and C6–7 was larger in the multiple plates fixation models, but opposite results were found in the three other movements. A similar trend was observed in the C3–6 fusion models.

Table 6 The value and percentage of ROM for different cervical segments from C2–7 in C4–6 ACDF models (°)
Table 7 The value and percentage of ROM for different cervical segments from C2–7 in C3–6 ACDF models (°)
Fig. 5
figure 5

The value and percentage of ROM for different cervical segments from C2–7. MP = multiple plates SP = single plates

Fig. 6
figure 6

Increase of ROM of adjacent segments in various motion states. MP = multiple plates SP = single plates

Table 8 Increase of ROM of adjacent segments in various motion states(%)

Loading of the adjacent disc

The stress distribution of the adjacent disc was analyzed and displayed on Table 9 and Fig. 7. Two main findings were found: (1) In C4–6 ACDF models, although the maximum stress of the adjacent IVD was close between the multiple plates fixation and single plate fixation, the peak stress of the multiple plates models was slightly smaller. In C3–6 ACDF models, the maximum stress of the adjacent IVD was larger in the single plate model under flexion, bending and rotation movements. (2) The maximum stress of the superior adjacent IVD was higher than that of the inferior adjacent IVD in all models and in all motion states.

Table 9 The peak stress of the intervertebral discs of adjacent segments in various motion states (MPa)
Fig. 7
figure 7

The peak stress of the intervertebral discs of adjacent segments in various motion states. MP = multiple plates SP = single plate

Discussion

ACDF has been reported to be effective for the treatment of CSM, particularly in cases with severe disc degeneration due to its efficiency with regards to decompression of the spinal cord and reconstruction of cervical spine stabilization [1, 2]. The overall rate of complications varied between 13.2 and 19.3% despite the satisfying stiffness and high fusion [29]. According to previous literature, dysphagia was the most common and immediate complication after surgery, occurring in 1.7 to 67% cases [30,31,32]. Although the majority of patients with post-operative dysphagia could recover within 3 months, 3–35% of patients would suffer sustained dysphagia and face a risk of impairment in nutrition and quality of life [30, 31]. Some factors were considered to potentially be associated with the dysphagia in previous studies, including numbers of levels involved, operation time, the size and type of plates, and the extent of tissue dissection and retraction [10, 33, 34]. For obese patients or patients with a short thick neck, surgeons might encounter difficulties installing the single multi-level plates ideally and lead to increased surgery duration time as well as more tissue dissection and retraction, and thus would face a higher risk of dysphagia and esophageal injury. The segmental fixation schedule could be considered to decrease the risk with similar stiffness when sufficient exposure could hardly be achieved in some cases.

Previous studies reported a 0.1–0.9% incidence of mechanical failure after ACDF surgery [32]. Selecting proper fixation instruments is critical for better outcomes in patients undergoing ACDF with osteoporosis, considering that osteoporosis is regarded as a risk factor for construct failure including screw pull-out and cage subsidence [35, 36]. The maximum Von-mises stress of the internal fixation indicated that in most situations the peak stress of the plates and stress is lower in multiple plates models. In other words, the risks of fatigue and failure were theoretically lower in the model. These results could be explained by the use of more screws to share the stress applied in the model. Meanwhile, the results showed that the multiple plates model had better biomechanical performance owing to the lower peak loading of the cage. The extent of subsidence is considered to be directly associated with the high stress concentration and discrepancy in the elastic modulus between the contact interfaces. Subsidence has become a concern given that it can result in the cervical misalignment and even breakage or pull-out of the screw [9, 37]. For patients with osteoporosis, the difference between the endplates and cage would increase as the elastic modulus of the endplates decrease. In the current study, the maximum stress of the cage was higher in the single plate fixation model. One reasonable explanation for this finding is that, compared with the single plate model, the multiple plates fixation provided more screws which could share the loading and then decrease the stress of the cage. Lower maximum cage stress was associated with a lower risk of cage subsidence. Moreover, previous studies have reported that osteoporosis is associated with a slower and less reliable fusion progress [38, 39]. In clinical practice, spine surgeons would face a dilemma when surgical treatment was required for patients with bone mass loss. In this situation, the multiple plates fixation with more screws combined with appropriate medications can be considered as one of the solutions.

Adjacent segment disease has been another problem with much concern. Increasing clinical and radiologic evidence has proved accelerated degeneration process of spinal segments adjacent to the fusion level [5, 27, 40]. A long-term (5–30 years) study including 166 patients reported that worse degenerative changes were found in over 90% patients who underwent ACDF. A similar percentage (>90%) of patients with radiographic ASD was also found in another retrospective study of 177 patients receiving ACDF treatment [40]. Among the patients involved, clinical ASD was found in 19.2, and 7% of the total patients required revision surgery. Several factors have been proven to be associated with ASD. It has been demonstrated that the ROM of the adjacent segment would increase to compensate for the sacrificed ROM at the fused segment [3]. In the current study, the ROM of the adjacent segments was lower in the multiple plates fixation in most simulation situations. In other words, the ROM did not indicate a higher risk of ASD in the multiple plates fixation models. In addition, the load distribution of the adjacent disc has been considered as another factor that was related to the occurrence of ASD, and some studies regarded it as a more important factor [3, 7]. Given that the nutrition acquirement of the IVD mainly relies on the diffusion and osmosis, the nutrition exchange might be affected by the continuous overload of IVD, leading to the acceleration of IVD degeneration [41]. Similar to the findings concerning ROM, the current study found that the maximum stress of the multiple plates fixation was lower compared to the single plate fixation in most situations. Thus, the multiple plates fixation might have better biomedical performance in preventing ASD. An explanation for this result might be the load sharing by more screws, which could decrease the loading of adjacent IVDs.

Despite the aforementioned advantages, some deficits of the multiple plates could not be ignored. First, although the multiple plates procedure might require less installation time when ACDF involving three to four segments was performed without satisfying the surgical field, the surgical procedure could be more complicated and lead to longer operative time if limited segments required fixation or the exposure was not difficult. Meanwhile, the stiffness increased as more screws were applied, but the risk of complications associated with screws input such as endplates fracture and posterior vertebral walls penetration would increase. And the medical cost would be higher for patients, considering that more plates and screws were used during the surgery. However, for patients with osteoporosis or other factors leading to a higher risk of construct failure, the multiple plates fixation could be taken into account for surgeons to balance the cost and the risk for revision surgery.

The current study has some limitations. As previous studies described, the major limitation of FE analysis is model simplification [24, 42, 43]. In other words, some acceptable idealized simulations were applied. The boundary and loading conditions are more complicated under actual in vivo condition. For example, the contact type between the screws, plates and vertebrae was set as the connection mode without micromotion but the situation could rarely be fully achieved, especially in the immediate period after ACDF. Although some settings such as the ‘tension only’ spring have been applied for better simulation, the idealized element could not perfectly simulate the biomechanical reactions of the ligaments. To make different models comparable and to avoid potential confounders, the parameters were set equally in all models to make the results more convincing. Another limitation was that the model was created based on the CT DICOM files from an asymptomatic volunteer without degeneration. As previously discussed, the simulation might perfectly reflect the actual clinical scenario but the study aimed to provide a trend and reference for future studies by taking advantage of FE analysis [43].

Conclusion

The FE analysis in the current study indicated a better biomechanical performance of the ACDF models with multiple plates fixation with regards to the stiffness and maintenance of the ROM in adjacent segments. These advantages are associated with a lower risk of related complications including construct failure and ASD. Meanwhile, the low-profile construct with multiple plates could possibility result in less injury to surrounding tissue, leading to a lower risk of post-operative dysphagia. The fixation schedule can be considered in some cases, such as in patients with osteoporosis.

Availability of data and materials

The datasets generated and/or analysed during the current study are not publicly available due to originality and individual privacy but are available from the corresponding author on reasonable request.

Abbreviations

ACDF:

Anterior cervical discectomy and fusio

ROM:

Range of motion

CT:

Computed tomography

IVD:

Intervertebral disc

ALL:

Anterior longitudinal ligament

PLL:

Posterior longitudinal ligament

LF:

Ligamentum flavum

ISL:

Interspinous ligament

SSL:

Supraspinous ligament

CL:

Capsular ligaments

MP:

Multiple plates

SP:

Single plate

STL:

Stereolithography

References

  1. Fehlings MG, Wilson JR, Kopjar B, Yoon ST, Arnold PM, Massicotte EM, et al. Efficacy and safety of surgical decompression in patients with cervical spondylotic myelopathy: results of the AOSpine North America prospective multi-center study. J Bone Joint Surg Am. 2013;95(18):1651–8.

    Article  PubMed  Google Scholar 

  2. Wang B, Liu H, Wang H, Zhou D. Segmental instability in cervical spondylotic myelopathy with severe disc degeneration. Spine. 2006;31(12):1327–31.

    Article  PubMed  Google Scholar 

  3. Eck JC, Humphreys SC, Lim TH, Jeong ST, Kim JG, Hodges SD, et al. Biomechanical study on the effect of cervical spine fusion on adjacent-level intradiscal pressure and segmental motion. Spine. 2002;27(22):2431–4.

    Article  PubMed  Google Scholar 

  4. Hilibrand AS, Carlson GD, Palumbo MA, Jones PK, Bohlman HH. Radiculopathy and myelopathy at segments adjacent to the site of a previous anterior cervical arthrodesis. J Bone Joint Surg Am. 1999;81(4):519–28.

    Article  CAS  PubMed  Google Scholar 

  5. Hilibrand AS, Robbins M. Adjacent segment degeneration and adjacent segment disease: the consequences of spinal fusion? Spine J. 2004;4(6 Suppl):190s–4s.

    Article  PubMed  Google Scholar 

  6. Lopez-Espina CG, Amirouche F, Havalad V. Multilevel cervical fusion and its effect on disc degeneration and osteophyte formation. Spine. 2006;31(9):972–8.

    Article  PubMed  Google Scholar 

  7. Stefanakis M, Luo J, Pollintine P, Dolan P, Adams MA. ISSLS prize winner: mechanical influences in progressive intervertebral disc degeneration. Spine. 2014;39(17):1365–72.

    Article  PubMed  Google Scholar 

  8. Zhang L, Wang J, Feng X, Tao Y, Yang J, Wang Y, et al. Outcome evaluation of zero-profile device used for single-level anterior cervical discectomy and fusion with osteoporosis compared without osteoporosis: a minimum three-year follow-up study. World Neurosurg. 2018;S1878-8750(18):32317–9.

    Google Scholar 

  9. Kao TH, Wu CH, Chou YC, Chen HT, Chen WH, Tsou HK. Risk factors for subsidence in anterior cervical fusion with stand-alone polyetheretherketone (PEEK) cages: a review of 82 cases and 182 levels. Arch Orthop Trauma Surg. 2014;134(10):1343–51.

    Article  PubMed Central  PubMed  Google Scholar 

  10. Riley LH 3rd, Skolasky RL, Albert TJ, Vaccaro AR, Heller JG. Dysphagia after anterior cervical decompression and fusion: prevalence and risk factors from a longitudinal cohort study. Spine. 2005;30(22):2564–9.

    Article  PubMed  Google Scholar 

  11. Park JB, Cho YS, Riew KD. Development of adjacent-level ossification in patients with an anterior cervical plate. J Bone Joint Surg Am. 2005;87(3):558–63.

    Article  PubMed  Google Scholar 

  12. Hua W, Zhi J, Ke W, Wang B, Yang S, Li L, et al. Adjacent segment biomechanical changes after one- or two-level anterior cervical discectomy and fusion using either a zero-profile device or cage plus plate: a finite element analysis. Comput Biol Med. 2020;120:103760.

    Article  PubMed  Google Scholar 

  13. He S, Feng H, Lan Z, Lai J, Sun Z, Wang Y, et al. A randomized trial comparing clinical outcomes between zero-profile and traditional multilevel anterior cervical discectomy and fusion surgery for cervical myelopathy. Spine. 2018;43(5):E259–e266.

    Article  PubMed  Google Scholar 

  14. Shen Y, Du W, Wang LF, Dong Z, Wang F. Comparison of zero-profile device versus plate-and-cage implant in the treatment of symptomatic adjacent segment disease after anterior cervical discectomy and fusion: a minimum 2-year follow-up study. World Neurosurg. 2018;115:e226–32.

    Article  PubMed  Google Scholar 

  15. Lu VM, Mobbs RJ, Fang B, Phan K. Clinical outcomes of locking stand-alone cage versus anterior plate construct in two-level anterior cervical discectomy and fusion: a systematic review and meta-analysis. Eur Spine J. 2019;28(1):199–208.

    Article  PubMed  Google Scholar 

  16. Ji GY, Oh CH, Shin DA, Ha Y, Kim KN, Yoon DH, et al. Stand-alone cervical cages versus anterior cervical plates in 2-level cervical anterior interbody fusion patients: analysis of adjacent segment degeneration. J Spinal Disord Tech. 2015;28(7):E433–8.

    Article  PubMed  Google Scholar 

  17. Finn MA, Samuelson MM, Bishop F, Bachus KN, Brodke DS. Two-Level Noncontiguous Versus Three-Level Anterior Cervical Discectomy and Fusion: A Biomechanical Comparison. Spine (Phila Pa 1976). 2011;36(6):448–53.

    Article  Google Scholar 

  18. Rios F, Eastlack RK. 217. Long cervical fusions: are multiple segmental plates less likely to fail than a single long plate? Spine J. 2021;21(9, Supplement):S111.

    Article  Google Scholar 

  19. Lin M, Shapiro SZ, Doulgeris J, Engeberg ED, Tsai CT, Vrionis FD. Cage-screw and anterior plating combination reduces the risk of micromotion and subsidence in multilevel anterior cervical discectomy and fusion-a finite element study. Spine J. 2021;21(5):874–82.

    Article  PubMed  Google Scholar 

  20. Ke W, Chen C, Wang B, Hua W, Lu S, Song Y, et al. Biomechanical evaluation of different surgical approaches for the treatment of adjacent segment diseases after primary anterior cervical discectomy and fusion: a finite element analysis. Front Bioeng Biotechnol. 2021;9:718996.

    Article  PubMed Central  PubMed  Google Scholar 

  21. Tsuang YH, Chiang YF, Hung CY, Wei HW, Huang CH, Cheng CK. Comparison of cage application modality in posterior lumbar interbody fusion with posterior instrumentation--a finite element study. Med Eng Phys. 2009;31(5):565–70.

    Article  PubMed  Google Scholar 

  22. Polikeit A, Ferguson SJ, Nolte LP, Orr TE. Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis. Eur Spine J. 2003;12(4):413–20.

    Article  PubMed  Google Scholar 

  23. Completo A, Nascimento A, Ramos A, Simões J. Failure analysis of C-5 after total disc replacement with ProDisc-C at 1 and 2 levels and in combination with a fusion cage: finite-element and biomechanical models. J Neurosurg Spine. 2015;22(6):639–46.

    Article  PubMed  Google Scholar 

  24. Galbusera F, Bellini CM, Costa F, Assietti R, Fornari M. Anterior cervical fusion: a biomechanical comparison of 4 techniques. Laboratory investigation. J Neurosurg Spine. 2008;9(5):444–9.

    Article  PubMed  Google Scholar 

  25. Mo Z, Li Q, Jia Z, Yang J, Wong DW, Fan Y. Biomechanical consideration of prosthesis selection in hybrid surgery for bi-level cervical disc degenerative diseases. Eur Spine J. 2017;26(4):1181–90.

    Article  PubMed  Google Scholar 

  26. Zhao L, Chen J, Liu J, Elsamaloty L, Liu X, Li J, et al. Biomechanical analysis on of anterior transpedicular screw-fixation after two-level cervical corpectomy using finite element method. Clin Biomech (Bristol, Avon). 2018;60:76–82.

    Article  Google Scholar 

  27. Lee JH, Park WM, Kim YH, Jahng TA. A biomechanical analysis of an artificial disc with a shock-absorbing Core property by using whole-cervical spine finite element analysis. Spine. 2016;41(15):E893–e901.

    Article  PubMed  Google Scholar 

  28. Lee SH, Im YJ, Kim KT, Kim YH, Park WM, Kim K. Comparison of cervical spine biomechanics after fixed- and mobile-core artificial disc replacement: a finite element analysis. Spine. 2011;36(9):700–8.

    Article  PubMed  Google Scholar 

  29. Epstein NE. A review of complication rates for anterior cervical Diskectomy and fusion (ACDF). Surg Neurol Int. 2019;10:100.

    Article  PubMed Central  PubMed  Google Scholar 

  30. Fountas KN, Kapsalaki EZ, Nikolakakos LG, Smisson HF, Johnston KW, Grigorian AA, et al. Anterior cervical discectomy and fusion associated complications. Spine. 2007;32(21):2310–7.

    Article  PubMed  Google Scholar 

  31. Vaishnav AS, Saville P, McAnany S, Patel D, Haws B, Khechen B, et al. Predictive factors of postoperative dysphagia in single-level anterior cervical discectomy and fusion. Spine. 2019;44(7):E400–e407.

    Article  PubMed  Google Scholar 

  32. Tasiou A, Giannis T, Brotis AG, Siasios I, Georgiadis I, Gatos H, et al. Anterior cervical spine surgery-associated complications in a retrospective case-control study. J Spine Surg. 2017;3(3):444–59.

    Article  PubMed Central  PubMed  Google Scholar 

  33. Lee MJ, Bazaz R, Furey CG, Yoo J. Influence of anterior cervical plate design on dysphagia: a 2-year prospective longitudinal follow-up study. J Spinal Disord Tech. 2005;18(5):406–9.

    Article  PubMed  Google Scholar 

  34. Wang T, Ma L, Yang DL, Wang H, Bai ZL, Zhang LJ, et al. Factors predicting dysphagia after anterior cervical surgery: a multicenter retrospective study for 2 years of follow-up. Medicine. 2017;96(34):e7916.

    Article  PubMed Central  PubMed  Google Scholar 

  35. Guzman JZ, Feldman ZM, McAnany S, Hecht AC, Qureshi SA, Cho SK. Osteoporosis in cervical spine surgery. Spine. 2016;41(8):662–8.

    Article  PubMed  Google Scholar 

  36. Lehman RA Jr, Kang DG, Wagner SC. Management of osteoporosis in spine surgery. J Am Acad Orthop Surg. 2015;23(4):253–63.

    Article  PubMed  Google Scholar 

  37. Lee YS, Kim YB, Park SW. Risk factors for postoperative subsidence of single-level anterior cervical discectomy and fusion: the significance of the preoperative cervical alignment. Spine. 2014;39(16):1280–7.

    Article  PubMed  Google Scholar 

  38. He YX, Zhang G, Pan XH, Liu Z, Zheng LZ, Chan CW, et al. Impaired bone healing pattern in mice with ovariectomy-induced osteoporosis: a drill-hole defect model. Bone. 2011;48(6):1388–400.

    Article  PubMed  Google Scholar 

  39. Pang J, Ye M, Gu X, Cao Y, Zheng Y, Guo H, et al. Ovariectomy-induced osteopenia influences the middle and late periods of bone healing in a mouse femoral osteotomy model. Rejuvenation Res. 2015;18(4):356–65.

    Article  CAS  PubMed  Google Scholar 

  40. Chung JY, Kim SK, Jung ST, Lee KB. Clinical adjacent-segment pathology after anterior cervical discectomy and fusion: results after a minimum of 10-year follow-up. Spine J. 2014;14(10):2290–8.

    Article  PubMed  Google Scholar 

  41. Arun R, Freeman BJ, Scammell BE, McNally DS, Cox E, Gowland P. 2009 ISSLS prize winner: what influence does sustained mechanical load have on diffusion in the human intervertebral disc?: an in vivo study using serial postcontrast magnetic resonance imaging. Spine. 2009;34(21):2324–37.

    Article  PubMed  Google Scholar 

  42. Li Y, Fogel GR, Liao Z, Tyagi R, Liu W. Prosthesis and hybrid strategy consideration for treating two-level cervical disc degeneration in hybrid surgery. Spine. 2018;43(6):379–87.

    Article  PubMed  Google Scholar 

  43. Wu TK, Meng Y, Liu H, Wang BY, Hong Y, Rong X, et al. Biomechanical effects on the intermediate segment of noncontiguous hybrid surgery with cervical disc arthroplasty and anterior cervical discectomy and fusion: a finite element analysis. Spine J. 2019;19(7):1254–63.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We extend sincere gratitude to the staff of the Department of Radiology for their assistance during this study.

Funding

This work was supported by grants from No.2021-NCRC-CXJJ-ZH-18 of Clinical Application-oriented Medical Innovation Foundation from National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation and Jiangsu China—Israel Industrial Technical Research Institute Foundation, and grants from Excellent Talent Training Award Program of Huashan Hospital, Fudan University.

Author information

Authors and Affiliations

Authors

Contributions

Weibo Huang and Ye Tian built the models, analyzed the results and wrote the manuscript. Hongli Wang and Ruoyu Li created the idea of the paper and reviewed the article. Fei Zou and Xiaosheng Ma were responsible for interpreting and discussing the clinical significance of the results. Jianyuan Jiang was responsible for supervision and project administration. The author(s) read and approved the final manuscript.

Corresponding authors

Correspondence to Jianyuan Jiang or Ruoyu Li.

Ethics declarations

Ethics approval and consent to participate

The study was approved by the institutional review board of Huashan Hospital, Fudan University, Shanghai (KY-2020-052) and informed consent was taken from the subject whose CT images were involved in the study. All methods were carried out in accordance with relevant guidelines and regulations.

Consent for publication

The patients provided their written informed consent to participate in this study for the publication of any potentially identifiable images or data included in this article.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Huang, W., Tian, Y., Wang, H. et al. Comparative analysis of the biomechanics of anterior cervical discectomy and fusion with multiple segmental plates fixation versus single multilevel plate fixation: a finite element study. BMC Musculoskelet Disord 23, 848 (2022). https://doi.org/10.1186/s12891-022-05796-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12891-022-05796-7

Keywords