Skip to main content

Evaluation of sparing the pronator quadratus for volar plating of distal radius fractures: a retrospective clinical study

Abstract

Background

The most commonly used approach for distal radius fractures is the traditional Henry approach. However, it requires an intraoperative incision of the pronator quadratus (PQ) muscle, which results in a series of complications if the repair of the PQ fails.

Aim

The objective of this study was to investigate the efficacy of sparing the pronator quadratus for volar plating of the distal radius fractures.

Methods

Seventy-six patients who suffered from distal radius fractures of types 23-B, 23-C1, and 23-C2 as per the AO Foundation and Orthopaedic Trauma Association (AO/OTA) classification were treated with volar locking plate fixation using either the PQ muscle incision and repair (group A, n = 39) or the PQ muscle preservation approach (group B, n = 37). Intraoperative index, postoperative efficacy and complications of patients were recorded and evaluated.

Results

All patients were followed up for more than one year after surgery. All fractures achieved union. There were significant differences in mean operative time, mean intraoperative blood loss, and mean fracture healing time between the two groups. Still, there were no significant differences in limb function scores between the two groups at the 12-month postoperative follow-up. Outcomes assessed at 1 week, 1 month, and 3 months after surgery demonstrated significant differences in the mean range of motion and pain-related visual analog scale (VAS) between the two groups. As the range of motion and grip strength increased, the VAS scores decreased, and there was no significant difference between the two groups at 12 months postoperatively. Although tendon irritation and delayed carpal tunnel syndrome were more common in group A than in group B (7.6% vs. 0% and 5.1% vs. 0%, respectively), the differences were not statistically significant.

Conclusion

The modified Henry approach with sparing pronator quadratus muscle has no significant advantage in the range of wrist motion and upper limb function in the late stage. Nevertheless, the intraoperative placement of the plate under the pronator quadratus muscle can shorten the operation time, reduce intraoperative bleeding, reduce early postoperative pain, promote early activity, and improve the patient's quality of life. It is recommended that the pronator be preserved at the time of surgery.

Peer Review reports

Background

Fractures of the distal radius are common and account for approximately 17% of fractures [1]. They are among the most common orthopedic injuries seen in the emergency room [2].This observation is partly due to increased life expectancy, leading to more osteoporotic fractures and an increasing variety of contact sports leading to high energy trauma in the younger population [3].

Volar locking plate fixation has become the standard surgical procedure for treating unstable distal radius fractures [4,5,6]. Johnson et al. [7] first reported the function of the pronator quadratus muscle to stabilize the distal ulnar radial joint in 1976. The most commonly used approach in distal radius fracture surgery is the traditional Henry approach, which requires slicing open the PQ muscle. There is great controversy regarding the significance of PQ muscle repair and whether the postoperative wrist function and outcomes are affected. Previous studies showed that even in patients with repaired PQ muscle [8], there is still a significant loss of strength in pronation after surgery, which may be related to tissue damage and edema or poor repair. Therefore, this study investigates the patient outcomes following intraoperative PQ muscle preservation with a posteriorly-placed plate.

Clinical data were collected from 76 patients with distal radius fractures who underwent open reduction and plate internal fixation. Patients were grouped based on whether the PQ muscle would be spared during the procedure or not. Intraoperative index, postoperative efficacy, and complications of the patients were evaluated. This retrospective comparative study aimed to investigate the effect of preserving the PQ muscle on wrist function in patients.

Methods

After the Institutional Review Board's written approval, a retrospective study was conducted between January 2019 and October 2020. 76 patients with distal radius fractures who underwent open reduction and plate internal fixation at the First Affiliated Hospital of Xinjiang Medical University were enrolled in the study. The PQ muscle was cut open in group A, while group B spared the PQ muscle. The inclusion criteria were: (1) age ≥ 18 years; (2) Unilateral displaced and unstable distal radius fractures; (3) Failure of manual reduction; and (4) AO classification 23-B, 23-C1, and 23-C2. The following patients were excluded: (1) ipsilateral or contralateral upper limb fractures and/or dislocation; (2) open fractures; (3) pathological fractures or metabolic bone disease; (4) Fractures greater than 3 weeks in duration; (5) associated nerve or vascular injury requiring repair; (6) Previous history of distal radius fracture on the affected side; (7) mental illness; (8) Poor compliance and lost follow-up.

Before the operation, a panel of experts needed to decide whether the patient should be treated with the PQ muscle sparing technique or the traditional technique. The final decision was then made depending on the actual situation during the operation. The same medical team carried out all surgical procedures. The patient demographics and fracture characteristics are displayed in Table 1. There was no significant difference in the pre-operative variables between the two groups.

Table 1 Baseline characteristics of the two groups

Surgical procedures

Patients were placed supine under general or regional anesthesia, and the surgery was performed. The Henry approach through the flexor carpi radialis (FCR) tendon sheath was applied for the Group A patients. The tendon was identified and mobilized to the radial edge of the incision. After incising the FCR tendon sheath, the PQ muscle was exposed and an L-shaped incision was performed along the radial border of the radius to the radial malleolus, and the PQ was then stripped off the radius. After the fragments were repositioned, fluoroscopic confirmation was obtained and a plate was inserted for internal fixation. The PQ was sutured using interrupted 3–0 and 4–0 absorbable sutures. The repair was abandoned if the PQ muscle was severely destroyed or edematous. For patients in Group B, if there was no primary injury to the PQ muscle, the fracture was repositioned without dissecting the PQ muscle by modifying the traditional Henry approach. After completion of the repositioning, a blunt separation between the PQ muscle and the periosteum was performed with a periosteal stripper to establish a tunnel posterior to the PQ muscle, through which the plate was placed. When the fracture was well repositioned and the plate was well positioned with X-ray fluoroscopy, the PQ muscle was bluntly separated with a mosquito clamp to reveal the screw holes and the screws were placed (Figs. 1 and 2).

Fig. 1
figure 1

a 55-year-old woman with a fall injury resulting in a left distal radius fracture of type B2 according to AO classification. b A tunnel was established under the PQ muscle during the operation. c The plate was placed below the PQ muscle. d Pre-incisional closure macrophotograph. e–f Preoperative x-ray of the affected limb. g-h Postoperative x-ray of the affected limb. i-l Wrist function at 3 months after surgery

Fig. 2
figure 2

A 21-year-old man with a fall injury resulting in a left distal radius fracture of type C1 according to AO classification. a, b Intraoperative sparing of the PQ muscle in the surgical approach. c-f Preoperative imaging of the affected limb. g-h Postoperative imaging of the affected limb. i-l Functional recovery of the wrist joint 3 months after surgery

Postoperative management

Following the surgery, all patients were on routine prophylactic antibiotics for 3 days and were not immobilized in plaster or brace. Patients were allowed to move their fingers immediately after surgery in both groups. Motion at the wrist joint was initiated 3 weeks post-surgery. At 6 weeks postoperatively, the patient's movement progressed to full active motion tolerated by each patient. Patients were allowed to resume full activity and weight-bearing after radiographic confirmation of fracture healing.

The patients were observed post-operatively for internal fixation loosening and complications such as flexor tendon irritation, traumatic arthritis, joint stiffness and carpal tunnel syndrome. The visual analog scale (VAS) scores of postoperative wrist pain and the forearm rotation angle between the two groups were compared. The Dienst score was used to assess the wrist function, and the imaging indexes (radial height, volar tilt, ulnar inclination) were used to evaluate the efficacy of the surgery.

Statistical analysis

SPSS Statistics software version 26.0 was used for the statistical analysis. All data were analyzed using a normal distribution test. Mean ± SD was used to represent measurement data with normal distribution. The student's t-test was used to compare measurement data of normal distribution. Conversely, a nonparametric Mann–Whitney U test was applied to compare two groups if the data did not display normal distribution, with data expressed as median and interquartile range. The count variables were analyzed by the Chi-square or Fisher's test, expressed as a number. P < 0.05 was considered statistically significant.

Results

Seventy-six patients who underwent palmar plating for distal radius fractures were enrolled in the study, 39 in Group A and 37 in Group B. All patients were followed up for more than one year after surgery (Figs. 1 and 2). There was a successful union of all fractures. Significant differences were found between the two groups' mean operative time, mean intraoperative blood loss, and mean fracture healing time (P = 0. 0, and 0.034, respectively). Still, there were no significant differences in limb function scores between the two groups at the 12-month postoperative follow-up (P = 0.362) (Table 2).

Table 2 Details of intra- and post-operative variables in the two groups

No intraoperative vascular injury wound complications, postoperative re-displacement, tendon rupture, or hardware failure were observed in either group. Moreover, there were no statistically significant differences in the postoperative imaging indexes (radial height, volar tilt, ulnar inclination) compared between the two groups (Table 3). Three patients (7.6%) in the A group suffered tendon irritation (two were not repaired due to severe PQ muscle damage and intraoperative repair difficulties), which was relieved after one year when the plate was removed in stage II. None of the sparing PQ group patients developed flexor tendon irritation after surgery. Two patients (5.1%) in Group A complained of delayed carpal tunnel syndrome.

Table 3 Postoperative imaging indexes

The range of motion measurements for each interval is shown in Fig. 4. Outcomes assessed at 1 week, 1 month, and 3 months after surgery demonstrated significant differences in the mean range of motion and pain-related VAS scores between the two groups. The mean values for all variables gradually improved over the year as the range of motion and grip increased and VAS scores decreased (Figs. 3, 4). There was no significant difference between the two groups at 12 months postoperatively.

Fig. 3
figure 3

One-year trend in VAS scores for groups A and B

Fig. 4
figure 4

One-year trends in forearm range of motion for group A and B

Discussion

There is controversy about whether to spare the PQ muscle intraoperatively in patients with distal radius fractures [9,10,11,12,13]. Even the repair of the PQ muscle after fracture reduction remains a topic of debate in the current literature. Some surgeons, including Goorens CK, believe that repairing the PQ muscle only relieves the patient's postoperative pain at an early stage [14, 15]. In addition, some surgeons consider that whether or not the PQ muscle is repaired intraoperatively is not significantly related to the patient's postoperative functional recovery of the wrist [16, 17]. Fenglei Shi concluded in a study that whether or not to repair the PQ muscle may not improve late wrist function in patients [18]. However, Chun-Kuan Lu suggested that repairing the PQ muscle may have some effects on pronation strength, and it is uncertain whether repairing the PQ is a protective factor in preventing flexor tendon complications [19].

Despite these statements, 83% of American hand surgeons repair the PQ muscle following volar plate fixation [20]. However, sometimes we are faced with the situation that the PQ muscle is hard to restore. We found that intraoperatively, the placement of the plate and the suturing of the PQ muscle were often difficult due to muscle tissue lesion, bleeding, and edema following incision of the PQ muscle. A clinical case observation study by Swigart et al. revealed that the failure rate of PQ muscle repair was 4%, with 1 in 24 patients failing [21]. It is now being proposed that maximum preservation of the PQ muscle can decrease intraoperative bleeding to enhance the repairable anterior rotator muscle [22, 23]. At the same time, some scholars recommend sparing the PQ muscle [24, 25] or completely repairing the PQ muscle at the end of surgery [25]. However, it is generally difficult to repair the PQ muscle at the radial margin of the radius because the muscle fascia is not strong enough to hold the sutures in place. Many recent studies have demonstrated that complete sparing of the PQ muscle relieved postoperative pain, improved rotational function, and facilitated the early functional recovery of the patient's wrist [26,27,28,29]. Similarly, this study confirmed that among 76 patients with unstable distal radius fractures, the 37 cases undergoing PQ muscle-sparing surgery demonstrated shorter operative time, less bleeding, fewer complications, less postoperative pain, and early functional wrist exercise, which facilitated the early functional recovery of the affected limb.

The use of volar locking plates for distal radius fractures has become increasingly popular in the last few years [30, 31]. Several studies have reported that patients achieve better functional scores and fewer complications postoperatively compared to other surgical techniques [11, 30, 31]. Despite the benefits of volar plating, complications are common, especially in the flexor tendons of the fingers and thumb (tenosynovitis, adhesions, ruptures) due to mechanical irritation between the volar plating and the tendons [32,33,34]. This technique can diminish these complications since the PQ muscle protects the flexor tendon and allows space for tendon gliding.

Jung et al. [35] measured the anatomy of the cadaveric specimen with CT imaging and concluded that the distal fracture of the radius was fixed using a small incision approach. The distal fracture fragment was large enough to place the distal row of screws without opening the PQ muscle, and the plate was appropriately placed. The PQ muscle covering the implant's surface prevents risks such as tendon abrasion, which indicates that the role of the PQ muscle in sheathing the implant cannot be ignored.

Carpal tunnel syndrome is a severe complication after surgical treatment of distal radius fractures [36,37,38]. Kashir et al. [23] first described an approach for splitting the brachioradialis muscle. By following this approach, they concluded that the integrity of the PQ was preserved, and all distal radius fractures requiring a volar plating could be treated without further incision. They reported no nerve injury or subluxation. However, it was found that this approach involves the radial artery during surgery, and the latter is highly susceptible to damage. Chul ki Goorens et al. obtained satisfactory results with the Minimally Invasive Pronator Quadratus Sparing Approach (MIPO) for distal radius fractures. However, this technique is more demanding for the surgeon [39], and the incision used in the MIPO technology for distal radius fractures are adjacent to the median nerve throughout the operation, and unfamiliarity with the procedure, repeated pulling of the incision, and placement of screws during the surgery may easily irritate the median nerve and cause nerve injury. Therefore, it was believed that adequate surgical field exposure is a prerequisite to avoid complications [27, 29].

The typical anatomical structure of the PQ muscle is the basis of its function [40]. It was found that the PQ muscles were heavily scarred, significantly atrophied, and adhered to the surrounding tissue after suturing. Muscle function is mainly impaired due to the distortion of its anatomy. This impairment is probably due to the disruption of the blood supply from the radial artery to the muscle after the latter has been severed. Hence, affecting the healing of the muscles.

Moreover, the PQ muscle is also a vital blood supply to the periosteum, with its provision from the anterior interosseous artery and the PQ muscle branches of the radial and ulnar arteries, as well as the posterior interosseous artery playing a crucial role in the healing of distal radius fractures. In this study, the mean bone healing time in the sparing PQ group was 11 weeks, lower than the 12 weeks in the conventional incision group. In addition, PQ muscle is a brittle piece of muscle, which is challenging to suture and often tears apart after suturing. The local soft tissue tension increases significantly, especially after the insertion of the plate, making it difficult to pull the muscle together.

Many studies have been reported on the treatment of distal radius fractures with various sparing of the PQ muscle, most of which analyzed the patients' near future postoperative functional recovery of the wrist. However, there are fewer studies on the long-term forearm rotation angles. In this study, we compared the long-term postoperative forearm and wrist function between two groups of patients with or without complete preservation of the anterior rotator muscle, and also focused on the postoperative pain scores of the patients. Satisfactory fracture reduction and good wrist function can be obtained with the palmar approach no matter whether the PQ muscle is preserved or not. Improved patient outcomes are observed when the respective surgical indications are mastered, and the articular surface reduction is adequate. However, preserving the PQ muscle to rehabilitate the forearm rotation is more advantageous in the short term.

It was previously believed that the PQ muscle was less critical, and that the anterior rotator function was limited; however, this is not the case. Jesper Sonntag et al. [41] concluded in a study that with or without repair of the PQ muscle after incision, ultrasound results showed that both were shorter than the healthy side. Still, the shortening was more significant in the unrepaired group. The function of the PQ muscle depends on its normal structure, and it is believed that incision of the PQ muscle with or without repair produces scarring that further affects forearm rotation function. Early forearm rotation is likely to cause a re-tear of the PQ muscle, leading to poor forearm function recovery. Therefore, it is recommended to avoid excessive forearm rotation for 3 weeks after surgery and wait for the scar repair of the PQ muscle to stabilize before active exercise, which is one of the reasons for the poor recovery of early forearm rotation. Nevertheless, it does not mean that the forearm rotation function is significantly limited at the later stage when the PQ muscle is dissected intraoperatively. This study showed no significant difference in the ROM of forearm rotation between the two groups at 12 months postoperatively. Hence, the sparing of the PQ muscle intraoperatively did not demonstrate a significant advantage in the long-term forearm rotation function. However, performing PQ muscle preservation is strongly recommended as it decreases the risk of muscle re-tear in rehabilitation, dramatically reduces the patient's pain, and encourages exercise.

In this surgical technique, it was found that bleeding before skin closure and after the release of the tourniquet were often minimal and sometimes did not even require any postoperative drainage system. It can be explained by the intact PQ muscle and by the cushioning effect of the muscle on the volar plate. The short duration of the procedure significantly decreases the risk of iatrogenic infection.

The AO classification and Fernandez classification are used to classify distal radius fractures, and the AO classification is more popular to guide treatment and determine prognosis. This study included the AO classification of distal radius fractures type B and C1 and C2. In addition, all types of fractures of the distal radius are generally treatable with a volar plate. However, in the case of type A fractures of extra-articular fractures, in order to avoid disruption of the blood supply and to reduce the burden of surgery on the patient, type A fractures are recommended to be treated with manual reduction and plaster fixation or external fixation combined with Kirschner wire since the fracture line is located at the level of the PQ muscle and the PQ muscle itself is a partial injury preoperatively. For comminuted fractures, a fragment-specific plate can be used for fixation.

Furthermore, the following data were collected from the surgical technique of PQ muscle locking plate preservation in the treatment of distal radius fractures. (1) The distal incision should not exceed the watershed line of the distal radius. Traumatic arthritis causes severe discomfort. (2) For dorsally displaced fracture blocks, especially AO fracture type B, reduction and fixation may be assisted by Kirschner wire or small dorsal incisions. (3) Intraoperative temporary fixation of Kirschner wire should be removed promptly after the insertion of 3–4 locking screws to avoid interfering with the implantation of other screws. (4) The implanted screws should not be too long to prevent damage to the dorsal extensor tendon. The ‘carpal shoot-through view’ can be used to determine whether the screws fixing the metaphysis have penetrated the carpal joint cavity [42]. (5) Repeated muscle traction during the procedure should be avoided to prevent secondary injury to nerves, blood vessels, and tendons. (6) Maintaining the wrist in the flexed position during the procedure facilitates reduction and fixation. (7) This approach does not reveal the carpal cavity, and further management of the cavity requires a combination of arthroscopic carpal techniques. (8) A possible drawback of sparing the pronator quadratus is the same as that of MIPO [39], both of which lack direct visualization of the fracture reduction. If intraoperative exposure and fixation reduction are problematic, traditional surgical fixation should be chosen as soon as possible.

With the development of the modern economy and the increasing aging population, the proportion of distal radius fractures presenting in an emergency is high; and people's demand for quality of life is increasing. The collective goal that doctors and patients pursue is achieving optimal recovery, reducing pain, and returning to society early with minimal trauma and tissue damage. In this study, the efficacy of sparing the PQ muscle in treating unstable distal radius fractures was investigated. It concluded that sparing the PQ muscle with a modified Henry approach is feasible for treating intra-articular fractures. The physiological structure of the PQ muscle is preserved, and the contact between the plate and the tendon and nerve is better isolated, which avoids stimulation of the nerve and tendon and reduces the possibility of tendon abrasion. Furthermore, the risk of tissue bleeding and edema after incision of the PQ muscle and eventually adhesions with the surrounding tissue is avoided. The disadvantage is that sparing the PQ muscle may complicate fracture reduction. It then requires fixation with the aid of multiple Kirschner wires or a small dorsal incision. It is not very operable for AO-type C3 distal radius fractures with serious comminution.

Several limitations existed in this study. First, its retrospective study design and the possibility of selection bias. Second, this was a single-center study that enrolled only a small number of patients. High-quality randomized controlled trials with a larger sample size are still needed to reinforce these results. Third, this study did not include distal radius C3 type fracture cases. A larger sample size containing more fracture patterns would be helpful in a future study.

Conclusion

The modified Henry approach with sparing pronator quadratus muscle has no significant advantage in the range of wrist motion and upper limb function in the long term. However, the intraoperative placement of the plate under the pronator quadratus muscle can shorten the operation time, reduce intraoperative bleeding, may reduce early postoperative pain, promote early activity, and improve patients' quality of life. It is recommended that the pronator be preserved at the time of surgery.

Availability of data and materials

The datasets analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

PQ:

Pronator quadratus

FCR:

The flexor carpi radialis

VAS:

The visual analogue scale scores

MIPO:

Minimally Invasive Plate Osteosynthesis

ROM:

Range of movement

References

  1. Via GG, Roebke AJ, Julka A. Dorsal Approach for Dorsal Impaction Distal Radius Fracture—Visualization, Reduction, and Fixation Made Simple. J Orthop Trauma. 2020;34:S15–6.

    Article  PubMed  Google Scholar 

  2. Chung KC, Spilson SV. The frequency and epidemiology of hand and forearm fractures in the United States. J hand surg. 2001;26(5):908–15.

    Article  CAS  Google Scholar 

  3. Smith DW, Henry MH. Volar fixed-angle plating of the distal radius. JAAOS-J Am Acad Orthop Surg. 2005;13(1):28–36.

    Article  Google Scholar 

  4. Quadlbauer S, Pezzei C, Jurkowitsch J, Rosenauer R, Pichler A, Schättin S, Hausner T, Leixnering M. Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate. Arch Orthop Traum Su. 2018;138(12):1773–82.

    Article  Google Scholar 

  5. Plant CE, Parsons NR, Costa ML. Do radiological and functional outcomes correlate for fractures of the distal radius? Bone Joint J. 2017;99(3):376–82.

    Article  PubMed  Google Scholar 

  6. Pang EQ, Truntzer J, Baker L, Harris A, Gardner MJ, Kamal RN. Cost minimization analysis of the treatment of distal radial fractures in the elderly. Bone Joint J. 2018;100(2):205–11.

    Article  PubMed  Google Scholar 

  7. Johnson RK, Shrewsbury MM. The pronator quadratus in motions and in stabilization of the radius and ulna at the distal radioulnar joint. J hand Surg. 1976;1(3):205–9.

    Article  CAS  Google Scholar 

  8. Armangil M, Bezirgan U, Başarır K, Bilen G, Demirtaş M, Bilgin SS. The pronator quadratus muscle after plating of distal radius fractures: is the muscle still working? Eur J Orthop Surg Traumatol. 2014;24(3):335–9.

    Article  PubMed  Google Scholar 

  9. Chloros GD, Papadonikolakis A, Ginn S, Wiesler ER. Pronator quadratus space and compartment syndrome after low-energy fracture of the distal radius: a case report. J Surg Orthop Adv. 2008;17(2):102.

    PubMed  Google Scholar 

  10. Berglund LM, Messer TM. Complications of volar plate fixation for managing distal radius fractures. JAAOS-J Am Acad Orthop Surg. 2009;17(6):369–77.

    Article  Google Scholar 

  11. Hershman SH, Immerman I, Bechtel C, Lekic N, Paksima N, Egol KA. The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures. J Orthop Trauma. 2013;27(3):130–3.

    Article  PubMed  Google Scholar 

  12. Mulders MA, Walenkamp MM, Bos FJ, Schep NW, Goslings JC. Repair of the pronator quadratus after volar plate fixation in distal radius fractures: a systematic review. Strategies Trauma Limb Reconstr. 2017;12(3):181–8.

    Article  PubMed  PubMed Central  Google Scholar 

  13. Kim JK, Park JS, Shin SJ, Bae H, Kim S. The effect of brachioradialis release during distal radius fracture fixation on elbow flexion strength and wrist function. J Hand Surg. 2014;39(11):2246–50.

    Article  Google Scholar 

  14. Häberle S, Sandmann GH, Deiler S, Kraus TM, Fensky F, Torsiglieri T, Rondak I, Biberthaler P, Stöckle U, Siebenlist S. Pronator quadratus repair after volar plating of distal radius fractures or not? Results of a prospective randomized trial. Eur J Med Res. 2015;20(1):1–8.

    Article  Google Scholar 

  15. Goorens CK, De Keyzer PB, Van Royen K, Provyn S, Goubau JF. Pronator quadratus repair after volar plate fixation in distal radial fractures: evaluation of the clinical and functional outcome and of the protective role on the flexor tendons—a randomized controlled study. Eur J Orthop Surg Traumatol. 2021;31(3):541–8.

    Article  CAS  PubMed  Google Scholar 

  16. Feeney MS, Wentorf F, Putnam MD. Simulation of altered excursion of the pronator quadratus. J wrist surg. 2014;3(03):198–202.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Nho J, Gong HS, Song CH, Wi SM, Lee YH, Baek GH. Examination of the pronator quadratus muscle during hardware removal procedures after volar plating for distal radius fractures. Clin Orthop Surg. 2014;6(3):267–72.

    Article  PubMed  PubMed Central  Google Scholar 

  18. Shi F, Ren L. Is pronator quadratus repair necessary to improve outcomes after volar plate fixation of distal radius fractures? A systematic review and meta-analysis. Orthop Traumatol Surg Res. 2020;106(8):1627–35.

    Article  PubMed  Google Scholar 

  19. Lu C, Liu W, Chang C, Shih C, Fu Y, Jupiter JB. A systematic review and meta-analysis of the pronator quadratus repair following volar plating of distal radius fractures. J Orthop Surg Res. 2020;15(1):1–9.

    Article  Google Scholar 

  20. Bertelli JA, Ghizoni MF. Reconstruction of C5 and C6 brachial plexus avulsion injury by multiple nerve transfers: spinal accessory to suprascapular, ulnar fascicles to biceps branch, and triceps long or lateral head branch to axillary nerve. J Hand Surg. 2004;29(1):131–9.

    Article  Google Scholar 

  21. Swigart CR, Badon MA, Bruegel VL, Dodds SD. Assessment of pronator quadratus repair integrity following volar plate fixation for distal radius fractures: a prospective clinical cohort study. J Hand Surg. 2012;37(9):1868–73.

    Article  Google Scholar 

  22. Hohendorff B, Unglaub F, Spies CK, Müller LP, Ries C. Refixierung des musculus pronator quadratus mit einem Teil des M.-brachioradialis-Ansatzes bei der palmaren Plattenosteosynthese einer distalen Radiusfraktur. Oper Orthop und Traumatol. 2020;32(1):82–6.

    Article  CAS  Google Scholar 

  23. Kashir A, Donnell T. A brachioradialis splitting approach sparing the pronator quadratus for volar plating of the distal radius. Tech Hand Up Extrem Surg. 2015;19(4):176–81.

    Article  PubMed  Google Scholar 

  24. Dos Remedios C, Nebout J, Benlarbi H, Caremier E, Sam-Wing J, Beya R. Préservation du muscle carré pronateur dans les ostéosynthèses des fractures de l’extrémité distale du radius par plaque palmaire verrouillée. Technique chirurgicale Chir Main. 2009;28(4):224–9.

    Article  Google Scholar 

  25. Heidari N, Clement H, Kosuge D, Grechenig W, Tesch NP, Weinberg AM. Is sparing the pronator quadratus muscle possible in volar plating of the distal radius? J Hand Surg (Eur Vol). 2012;37(5):402–6.

    Article  CAS  Google Scholar 

  26. Liverneaux PA. The minimally invasive approach for distal radius fractures and malunions. J Hand Surg (Eur Vol). 2018;43(2):121–30.

    Article  Google Scholar 

  27. Liverneaux P, Ichihara S, Facca S, Diaz JH. Résultats de l’ostéosynthèse par plaque antérieure et abord mini-invasif (MIPO) des fractures de l’extrémité distale du radius: mise au point. Hand Surg Rehabil. 2016;35:S80–5.

    Article  Google Scholar 

  28. Rey P, Rochet S, Loisel F, Obert L. how to spare the pronator quadratus during MIPO of distal radius fractures by using a mini-volar plate. Chir Main. 2014;33(2):95–9.

    Article  PubMed  Google Scholar 

  29. Salgarello M, Visconti G, Barone-Adesi L. Interlocking circumareolar suture with undyed polyamide thread: a personal experience. Aesthet Plast Surg. 2013;37(5):1061–2.

    Article  Google Scholar 

  30. Huang H, Wang J, Chang M. Repair of pronator quadratus with partial muscle split and distal transfer for volar plating of distal radius fractures. J Hand Surg. 2017;42(11):931–5.

    Article  Google Scholar 

  31. Ruchelsman DE, Klugman JA, Madan SS, Chorney GS. Anterior dislocation of the radial head with fractures of the olecranon and radial neck in a young child: a Monteggia equivalent fracture-dislocation variant. J Orthop Trauma. 2005;19(6):428–31.

    Article  Google Scholar 

  32. Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007;21(5):316–22.

    Article  PubMed  Google Scholar 

  33. Duncan SF, Weiland AJ. Delayed rupture of the flexor pollicis longus tendon after routine volar placement of a T-plate on the distal radius. AMERICAN JOURNAL OF ORTHOPEDICS-BELLE MEAD-. 2007;36(12):669.

    Google Scholar 

  34. Rampoldi M, Marsico S. Complications of volar plating of distal radius fractures. Acta Orthop Belg. 2007;73(6):714.

    PubMed  Google Scholar 

  35. Jung G, Cho C, Kim J. Anatomical study of the pronator quadratus muscle and comparison to fracture sites of the distal radius. Journal of the Korean Orthopaedic Association. 2012;47(1):48–53.

    Article  Google Scholar 

  36. Gradl G, Mielsch N, Wendt M, Falk S, Mittlmeier T, Gierer P, Gradl G. Intramedullary nail versus volar plate fixation of extra-articular distal radius fractures. Two year results of a prospective randomized trial. Injury. 2014;45:S3–8.

    Article  PubMed  Google Scholar 

  37. Gradl G, Falk S, Mittlmeier T, Wendt M, Mielsch N, Gradl G. Fixation of intra-articular fractures of the distal radius using intramedullary nailing: a randomized trial versus palmar locking plates. Injury. 2016;47:S25–30.

    Article  PubMed  Google Scholar 

  38. Pierrart J, Tordjman D, Ikeuchi N, Delgrande D, Gregory T, Masmejean E. Lésions nerveuses associées aux fractures de l’extrémité distale du radius. Hand Surgery and Rehabilitation. 2016;35:S75–9.

    Article  Google Scholar 

  39. Ki Goorens C, Debaenst N, Van Royen K, Provyn S, Goubau JF. Minimally Invasive Pronator Quadratus Sparing Approach versus Extended Flexor Carpi Radialis Approach with Pronator Quadratus Repair for Volar Plating in Distal Radial Fractures. Journal of Wrist Surgery. 2022;11(01):41–7.

    Article  Google Scholar 

  40. Fang K, Lin X, Liu X, Ke Q, Shi S, Dai Z. Do we need to suture the pronator quadratus muscle when we do open reduction and internal fixation for fracture of the distal radius. Bmc Musculoskel Dis. 2020;21(1):1–7.

    Article  Google Scholar 

  41. Sonntag J, Hern J, Woythal L, Branner U, Lange KH, Brorson S. The Pronator quadratus muscle after Volar plating: ultrasound evaluation of anatomical changes correlated to patient-reported clinical outcome. Hand. 2021;16(1):32–7.

    Article  PubMed  Google Scholar 

  42. Marsland D, Hobbs CM, Sauvé PS. Volar locking plate fixation of distal radius fractures: use of an intra-operative ‘carpal shoot through’view to identify dorsal compartment and distal radioulnar joint screw penetration. Hand. 2014;9(4):516–21.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

Not applicable.

Disclosure

The authors report no proprietary or commercial interest in any product mentioned or concept discussed in this article.

Funding

This study was not funded by any foundation.

Author information

Authors and Affiliations

Authors

Contributions

XH: Conducted the study. Collected, analyzed, and interpreted the data. Wrote the manuscript. QJ: Designed the study, and interpreted the data, and edited the manuscript. HL: Planned the project. Interpreted the data. EK: Interpreted the data. CP: Interpreted the data. WK: Edited the manuscript, reviewed the manuscript. MT: Edited the manuscript, reviewed the manuscript. YH: Edited the manuscript. DF: Edited the manuscript. YZ: Planned the project. Reviewed the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Yan Zhao.

Ethics declarations

Ethics approval and consent to participate

This retrospective study was approved by the Ethics Committee of The First Affiliated Hospital of Xinjiang Medical University and carried out in accordance with the ethical standards set out in the Helsinki Declaration. Informed consent was received from all participating.

Consent for publication

Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor of this journal.

Competing interests

The authors declare that they have no conflict of interest.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary information

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Huang, X., Jia, Q., Li, H. et al. Evaluation of sparing the pronator quadratus for volar plating of distal radius fractures: a retrospective clinical study. BMC Musculoskelet Disord 23, 625 (2022). https://doi.org/10.1186/s12891-022-05576-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12891-022-05576-3

Keywords