Comparison of monoplanar and polyaxial screw fixation systems in percutaneous intermediate fixation for thoracolumbar fractures

Abstract

Background

The newly developed monoplanar pedicle screws (MPPSs) can mobile in axial plane but fixed in the sagittal plane, which holds potential to combine ease of rod placement with sagittal plane strength theoretically. So far, few clinical studies focused on the outcomes of MPPSs for treatment of thoracolumbar fractures (TLFs). The aim of this study was to compare the efficacy of MPPSs to polyaxial pedicle screws (PAPSs) in percutaneous intermediate fixation of TLFs.

Methods

Seventy-eight patients who sustained TLFs without neurological deficits and underwent percutaneous intermediate fixation using MPPSs (40 patients) or PAPSs (38 patients) with a minimum 1-year follow-up were included in this study. The operation time, blood loss, local Cobb angle (LCA), vertebral wedge angle (VWA), anterior body height ratio (ABHR), visual analogue scale (VAS) and Oswestry Disability Index (ODI) were collected.

Results

No significant differences were observed in baseline demographics, clinical characteristics, operation time or blood loss between the two groups (P > 0.05). The postoperative LCA, VWA and ABHR were significantly corrected compared to these parameters preoperatively in both groups (#P < 0.05). The postoperative LCA, VWA and ABHR in the MPPS group were significantly better corrected than those in the PAPS group (*P < 0.05). Furthermore, the correction loss of LCA, VWA and ABHR in the MPPS group was significantly lower than that in the PAPS group (*P < 0.05). However, no significant difference in VAS and ODI scores was observed between the two groups.

Conclusions

MPPSs showed similar efficiency as PAPSs in percutaneous intermediate fixation surgical procedures. More importantly, MPPSs achieved better radiological performance than PAPSs in the correction of TLFs and the prevention of correction loss.

Peer Review reports

Background

Spine fractures are commonly observed in traffic accidents, height crashes and other high-energy injuries, and they account for 5% of all trauma patients [1]. Approximately 60–70% of all traumatic spinal fractures are thoracolumbar fractures (TLFs, from T11 to L2), which is ascribed to the special biomechanical characteristics of the thoracolumbar spine that translate from the rigid, kyphotic thoracic spine to the mobile, lordotic lumbar spine [2]. Surgical or conservative management of TLFs remains controversial, especially for patients without neurological deficits [3, 4].

In recent years, minimally invasive percutaneous pedicle screw fixation (PPSF) for TLFs has been growing in popularity [5,6,7]. The typical PPSF for TLFs is 4-screw fixation with pedicle screws introduced to one level above and below the injured vertebra. Recently, a series of studies have documented that percutaneous intermediate fixation (PIF), which adds two screws in the fractured vertebra, provides stronger fixation than traditional 4-screw fixation [2, 8, 9]. In addition, PIF is more effective in restoring and maintaining fractured vertebral height [2, 9,10,11]. The thoracolumbar spine is the junctional area from a narrow thoracic spine to a wider lumbar spine; it requires inserting screws with high alignment, and slight deviation of the ipsilateral three screws might make it difficult to insert the longitudinal rod, especially using fixed-axis pedicle screws in PIF (6-screw fixation) [12, 13]. The polyaxial pedicle screw (PAPS) increases the degrees of freedom at the screw-rod interface and provides greater ease for rod insertion, making PAPSs more favourable than traditional fixed-axis pedicle screws in minimally invasive surgeries [12, 13]. PAPSs show less stiffness in the sagittal plane and inferior fracture reduction compared to fixed-axis pedicle screws in TLFs [12, 14].

Recently, a novel type of pedicle screw, monoplanar pedicle screw (MPPS), has been introduced. MPPS is designed to be mobile in the axial plane but fixed in the sagittal plane. Thus, MPPS behaves as a fixed-axis pedicle screw in the sagittal plane and a PAPS in the axial plane. A series of recent biomechanical studies have demonstrated that MPPSs significantly increase stiffness in the sagittal plane compared to PAPSs [15,16,17]. Theoretically, MPPSs may combine the ease of rod insertion with sagittal plane strength.

To our knowledge, few clinical studies have focused on the outcomes of MPPSs for the treatment of TLFs. The objectives of this study were to compare the efficacy of MPPSs to PAPSs in PIF for TLFs without neurological deficits.

Methods

Patient population

A retrospective study was adopted to review patients who underwent PIF surgery using MPPSs or PAPSs from January 2017 to May 2020. A total of 78 patients were enrolled in this study. The patients were divided into two groups: those treated with the MPPS system were included in the MPPS group; those treated with the PAPS system were included in the PAPS group. All protocols were approved by the Ethics Committee of General Hospital of Central Theater Command (approval number: [2021]040) and were performed in compliance with the Helsinki Declaration.

Inclusion and exclusion criteria

The inclusion criteria for patients were as follows: traumatic fracture of T11-L2; type A3 and A4 with or without type B2 in AO classification of spinal fracture [18]; without neurologic deficit; age 18 to 60 years; less than 2 weeks between trauma and surgery; and followed up for more than 12 months. Patients with the following criteria were excluded: fractures of more than 2 vertebrae; presence of nerve injury symptoms; pregnancy; pathologic or osteoporotic fracture; bilateral pedicle fracture; and a history of previous spinal surgery. The general information of the patients is summarized in Table 1.

Table 1 Baseline demographic and clinical characteristics of patients

Surgical procedures

All surgeries were performed by fully qualified spine surgeons as reported previously (Fig. 1) [19,20,21]. Under general endotracheal anaesthesia, all patients were operated in the prone position on a Jackson operating table with chest and pelvis supported by a pad and abdomen suspended. The location of the pedicles of the fractured level, and one level above and below the injured vertebra were marked according to the posteroanterior fluoroscopy. One surgeon applied manual forces on the fractured vertebra by his hands under intermittent C-arm fluoroscopic guidance (Fig. 1b). Continuous neuromonitoring was utilized to monitor neural function. Skin incisions were made 1.5-cm lateral from the marks of those pedicles. Each pedicle was cannulated by a Jamshidi needle with proper direction and depth. A guidewire was placed into the vertebral body through the needle. The pedicle screw was inserted into the pedicle and vertebral body along the wire. There were six percutaneous pedicle screws (one level above and below the injured vertebra as well as the fractured level) implanted into each patient’s thoracolumbar region in both MPPS group and PAPS group [22]. After implantation of all six screws, rods with appropriate length and bending were inserted (Fig. 1d). The TLF was further corrected by applying a hyperlordosing force through the posterior elements before tightening the screws (Fig. 1e). Posteroanterior fluoroscopy and lateral fluoroscopy were conducted to verify the reduction effect (Fig. 1f). The duration of operation time and the amount of blood loss were recorded. Postoperative management was performed as reported previously [23, 24]. All patients were encouraged to partake in ambulatory activities while wearing a brace 3 days after surgery.

Fig. 1
figure 1

Representative images of surgical procedures of a 57-year-old male patient in the MPPS group. a Representative image of MPPSs. b Application of manual forces on the fractured vertebra to correct kyphosis. c Six Jamshidi needles were inserted into the pedicles and vertebral bodies. (d) Six MPPSs were implanted into the thoracolumbar region and two rods with appropriate length and bending were inserted. e TLF was further corrected by applying a hyperlordosing force through the posterior elements before tightening the screws. f The location of internal fixation and correction of kyphosis were confirmed, and the incisions were closed

Clinical evaluation

Low back pain was evaluated by the VAS (0–10 scale). The functional outcomes were assessed by ODI as described previously [25]. The VAS score and ODI were assessed preoperatively, 5 days postoperation, 1 month postoperation and at the last follow-up.

Radiological evaluation

Thoracolumbar anterior-posterior and lateral X-rays in addition to thoracolumbar computed tomography (CT) and magnetic resonance imaging (MRI) were obtained before the operation to evaluate the fracture. The LCA, VWA and ABHR (Fig. 2) were evaluated by lateral X-rays. The LCA was measured between the superior endplate of the vertebra above the injured vertebra and inferior endplate of the vertebra below the injured vertebra. VWA was defined as the Cobb angle of the fractured vertebra, and ABHR was defined as the percentage of the anterior body high of fractured vertebra to the mean value of the adjacent vertebrae. All data were measured by two independent observers who were blinded to the group assignment.

Fig. 2
figure 2

Measurement of radiological parameters. LCA, local Cobb angle; VWA, vertebral wedge angle; ABHR, anterior body height ratio (ABHR = h2 / [(h1 + h3) / 2] × 100%)

Statistical analyses

Continuous variables are presented as the mean ± SD and were evaluated by Student’s t test. Categorical variables are presented as numbers and were compared utilizing the chi-square test or Fisher’s exact test. A statistical significance level of P < 0.05 was applied. Statistical analyses were conducted by SPSS 23.0 (IBM, New York, USA).

Results

In total, 78 patients with traumatic TLFs were included as follows: 40 patients received MPPSs, and 38 patients received PAPSs. The demographic data and clinical characteristics of all patients are shown in Table 1. There was no significant difference in age, sex, fracture mechanism, fracture level or AO classification between the two groups (P > 0.05). The average TLICS was 4.0 ± 0.7 (3–5) in both groups (P > 0.05). The average time of follow-up was 15.9 ± 3.2 (12.2–24.8) months for the MPPS group and 16.6 ± 3.9 (12.5–26.3) months for the PAPS group (P > 0.05). The mean operation time was 80.5 ± 15.4 (64.3–119.5) min in the MPPS group and 78.3 ± 16.2 (63.8–125.5) min in the PAPS group (P > 0.05). The blood loss was 87.5 ± 37.1 (45–155) ml in the MPPS group and 80.3 ± 34.0 (40–165) ml in the PAPS group (P > 0.05).

As shown in Table 2, there was no significant difference in the preoperative LCA, VWA or ABHR between the MPPS and PAPS groups (P > 0.05). As expected, the postoperative LCA, VWA and ABHR were significantly corrected compared to these parameters preoperatively in both groups (Table 2, Fig. 3 and Fig. 4, #P < 0.05). The postoperative LCA in the MPPS group (6.0° ± 5.1°) was significantly lower than that in the PAPS group (9.2° ± 4.7°, *P < 0.05). Similarly, the postoperative VWA and ABHR in the MPPS group were also significantly better corrected than those in the PAPS group (*P < 0.05). Both the MPPS and PAPS groups showed correction loss with time. Importantly, the LCA, VWA and ABHR in the MPPS group at the last follow-up remained significantly better than those in the PAPS group (*P < 0.05). In addition, significant differences were also found in the correction loss of LCA, VWA and ABHR between the two groups (Table 2, *P < 0.05).

Table 2 Summary of radiographic measurements
Fig. 3
figure 3

A 39-year-old male patient from the MPPS group. Preoperative X-ray (a) and CT (b) demonstrated T12 AO type B2A3 fracture without apparent neurological deficit. There was marked widening of the interspinous distance between T11 and T12. MRI (c) showed fresh fracture of the T12 vertebral and interspinous ligament injury. Postoperative X-ray (d) and CT (e - f) showed satisfactory traumatic kyphosis correction and vertebral height restoration. X-ray image (g) at 15 months following surgery

Fig. 4
figure 4

A 45-year-old female patient from the PAPS group. Preoperative X-ray (a) and CT (b) demonstrated a T12 AO type B2A3 fracture without apparent neurological deficits. The arrow indicates the fracture of the T11 spinous process. MRI (c) showed fresh fracture of the T12 vertebral and T11 spinous processes. Postoperative X-ray (d) and CT (e - f) showed satisfactory traumatic kyphosis correction and vertebral height restoration. X-ray image (g) at 14 months following surgery

The VAS for back pain and ODI scores were significantly improved following surgery in both groups (Table 3, #P < 0.05) and gradually improved with time. However, no significant differences were found in VAS and ODI between the two groups at any time point (Table 3, P > 0.05). There were no major vascular injuries or neurologic complications. No patient required revision for correction loss or instrumentation failure at the last follow-up.

Table 3 Clinical outcomes between the two groups

Discussion

Traumatic TLFs are commonly observed in traffic accidents, height crashes and other high-energy injury situations [1]. Open surgery has been recommended for patients with neurological deficits and unstable TLFs to decompress the nerve and stabilize the spine. For patients without neurological deficits, decompression is not required, and the treatment focuses on recovering the height of the fractured vertebra, restoring the stability of the spine and avoiding complications due to posttraumatic kyphosis and prolonged bed rest [26]. Minimally invasive PPSF exhibits better fracture reduction and long-term clinical outcomes than nonoperative treatment, and it provides three-column fixation similar to open surgery and shows less soft tissue injury, lower infection risk, less postoperative pain and shorter rehabilitation time than traditional open surgery [5,6,7]. Therefore, PPSF has been growing in popularity for the treatment of TLFs [7]. With the development of PPSF, more recent studies have demonstrated that PIF, which adds two screws to the fractured vertebra, is more effective in restoring and maintaining fractured vertebral height than the classic 4-screw PPSF [2]. In the present study, all the patients received PIF using six pedicle screws. Our results showed that the LCA, VWA and ABHR were significantly corrected by surgery in both groups. Our results provided further evidence that PIF effectively recovers the height of fractured vertebrae and corrects kyphosis.

In PIF surgery, high alignment of the ipsilateral three screws is required for successful installation of the longitudinal connecting rod, especially using fixed-axis pedicle screws. Deviation in the position of screw placement may increase the difficulty of surgery and prolong the operation time [12, 13]. PAPSs increase the degrees of freedom at the screw-rod interface and provide greater ease for rod insertion. However, it has been reported that fixed-axis pedicle screws provide better correction of deformities than PAPSs [14]. In an effort to combine the relative advantages of fixed-axis pedicle screws and PAPSs, MPPSs were developed. MPPSs are mobile in the axial plane (see Additional file 1), which may facilitate rod insertion and improve surgical efficiency. In the present study, the mean operation time and blood loss showed no significant difference between the MPPS group and the PAPS group (P > 0.05). These results indicated that the operating efficiencies of MPPSs and PAPSs were comparable.

MPPSs are rigid in the sagittal plane and behave as fixed-axis screws in the sagittal plane (see Additional file 1) [16], potentially achieving better fracture reduction and kyphotic angle correction similar to fixed-axis screws. In line with this hypothesis, our results demonstrated that the LCA, VWA, and ABHR were better corrected by MPPSs than PAPSs. In addition, MPPSs showed less correction loss than PAPSs with prolonged follow-up.

In the present study, statistically significant differences were not observed in the VAS and ODI scores between the two groups. The following reasons might account for this lack of statistical difference: 1) both MPPS and PAPS fixation procedures are minimally invasive procedures that cause little damage to paraspinal soft tissues [6, 26]; and 2) one of the most important reasons for functional defects after TLF is pain caused by the jiggle of the fractured vertebra under loading-bearing stress, buckling stress and rotation stress, and both MPPS and PAPS fixation provide sufficient strength to stabilize the fractured vertebra and minimize the pain caused by the jiggle of the fractured vertebra. Further studies with long-term follow-up after the removal of instrumentations might clarify whether the promising radiological results in the MPPS group translate to superior functional outcomes.

There were several limitations to this study. First, this was a retrospective study without randomization, potentially resulting in selection bias. A randomized, prospective study is warranted to further confirm these findings. Second, this was a one-center study, and the sample size remained small. Third, the follow-up time was relatively short without removal of instrumentations. It would be interesting to investigate the long-term functional outcomes, correction loss and adjacent segment degeneration after the removal of instrumentations in future studies.

Conclusions

In summary, MPPSs and PAPSs showed similar operation times, blood loss and clinical outcomes in PIF of thoracolumbar fractures. The LCA, VWA, and ABHR were better corrected by MPPSs than PAPSs. In addition, MPPSs showed less correction loss than PAPSs with prolonged follow-up. These results highlighted that MPPS fixation system was a highly efficient fixation system as PAPS in PIF surgical procedures and MPPSs achieved better radiological performance than PAPSs in the correction of TLFs and the prevention of correction loss.

Availability of data and materials

The datasets analysed during the current study are available from the corresponding author on reasonable request.

Abbreviations

ABHR:

Anterior body height ratio

CT:

Computed tomography

LCA:

Local Cobb angle

MRI:

Magnetic resonance imaging

MPPS:

Monoplanar pedicle screws

ODI:

Oswestry Disability Index

PAPS:

Polyaxial pedicle screws

PIF:

Percutaneous intermediate fixation

TLF:

Thoracolumbar fractures

VAS:

Visual analogue scale

VWA:

Vertebral wedge angle

References

  1. Liu P, Yao Y, Liu M, Fan W, Chao R, Wang Z, et al. Spinal trauma in mainland China from 2001 to 2007: an epidemiological study based on a nationwide database. Spine (Phila Pa 1976). 2012;37(15):1310–5.

    Article  Google Scholar 

  2. Li K, Li Z, Ren X, Xu H, Zhang W, Luo D, et al. Effect of the percutaneous pedicle screw fixation at the fractured vertebra on the treatment of thoracolumbar fractures. Int Orthop. 2016;40(6):1103–10.

    Article  Google Scholar 

  3. Caruso G, Lombardi E, Andreotti M, Lorusso V, Gildone A, Padovani S, et al. Minimally invasive fixation techniques for thoracolumbar fractures: comparison between percutaneous pedicle screw with intermediate screw (PPSIS) and percutaneous pedicle screw with kyphoplasty (PPSK). Eur J Orthop Surg Traumatol. 2018;28(5):849–58.

    Article  Google Scholar 

  4. Aleem IS, Nassr A. Cochrane in CORR(®): surgical versus non-surgical treatment for thoracolumbar burst fractures without neurological deficit. Clin Orthop Relat R. 2016;474(3):619–24.

    Article  Google Scholar 

  5. Siebenga J, Leferink VJM, Segers MJM, Elzinga MJ, Bakker FC, Haarman HJTM, et al. Treatment of traumatic thoracolumbar spine fractures: a multicenter prospective randomized study of operative versus nonsurgical treatment. Spine (Phila Pa 1976). 2016;31(25):2881–90.

    Article  Google Scholar 

  6. Kim D, Lee S, Chung SK, Lee H. Comparison of multifidus muscle atrophy and trunk extension muscle strength: percutaneous versus open pedicle screw fixation. Spine (Phila Pa 1976). 2005;30(1):123–9.

    Article  Google Scholar 

  7. Vanek P, Bradac O, Konopkova R, de Lacy P, Lacman J, Benes V. Treatment of thoracolumbar trauma by short-segment percutaneous transpedicular screw instrumentation: prospective comparative study with a minimum 2-year follow-up. J Neurosurg Spine. 2014;20(2):150.

    Article  Google Scholar 

  8. Dick JC, Jones MP, Zdeblick TA, Kunz DN, Horton WC. A biomechanical comparison evaluating the use of intermediate screws and cross-linkage in lumbar pedicle fixation. J Spinal Disord. 1994;7(5):402–7.

    Article  CAS  Google Scholar 

  9. Norton RP, Milne EL, Kaimrajh DN, Eismont FJ, Latta LL, Williams SK. Biomechanical analysis of four- versus six-screw constructs for short-segment pedicle screw and rod instrumentation of unstable thoracolumbar fractures. Spine J. 2014;14(8):1734–9.

    Article  Google Scholar 

  10. Ye C, Luo Z, Yu X, Liu H, Zhang B, Dai M. Comparing the efficacy of short-segment pedicle screw instrumentation with and without intermediate screws for treating unstable thoracolumbar fractures. Medicine. 2017;96(34):e7893.

    Article  Google Scholar 

  11. Liu H, Wang H, Liu J, Li C, Zhou Y, Xiang L. Biomechanical comparison of posterior intermediate screw fixation techniques with hybrid monoaxial and polyaxial pedicle screws in the treatment of thoracolumbar burst fracture: a finite element study. J Orthop Surg Res. 2019;14(1):122.

    Article  Google Scholar 

  12. Wang H, Zhao Y, Mo Z, Han J, Chen Y, Yu H, et al. Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review. Clinics. 2017;72(10):609–17.

    Article  Google Scholar 

  13. Liu PLai P, Lin C. A biomechanical investigation of different screw head designs for vertebral derotation in scoliosis surgery. Spine J. 2017;17(8):1171–9.

    Article  Google Scholar 

  14. Chung WH, Eu WC, Chiu CK, Chan CYW, Kwan MK. Minimally invasive reduction of thoracolumbar burst fracture using monoaxial percutaneous pedicle screws: surgical technique and report of radiological outcome. J Orthop Surg-Hong K. 2020;28(1):920548385.

    Google Scholar 

  15. Ye B, Yan M, Zhu H, Duan W, Hu X, Ye Z, et al. Novel screw head design of pedicle screw for reducing the correction loss in the patients with thoracolumbar vertebral fractures: a biomechanical study. Spine (Phila Pa 1976). 2017;42(7):E379–84.

    Article  Google Scholar 

  16. Schroerlucke SR, Steklov N, Mundis GM, Marino JF, Akbarnia BA, Eastlack RK. How does a novel monoplanar pedicle screw perform biomechanically relative to monoaxial and polyaxial designs? Clin Orthop Relat Res. 2014;472(9):2826–32.

    Article  Google Scholar 

  17. Lam FCGroff MW, Alkalay RN. The effect of screw head design on rod derotation in the correction of thoracolumbar spinal deformity: laboratory investigation. J Neurosurg Spine. 2013;19(3):351.

    Article  Google Scholar 

  18. Reinhold M, Audigé L, Schnake KJ, Bellabarba C, Dai L, Oner FC. AO spine injury classification system: a revision proposal for the thoracic and lumbar spine. Eur Spine J. 2013;22(10):2184–201.

    Article  Google Scholar 

  19. Xu Y, Zhou X, Yu C, Cheng M, Dong Q, Qian Z. Effectiveness of postural and instrumental reduction in the treatment of thoracolumbar vertebra fracture. Int Orthop. 2008;32(3):361–5.

    Article  Google Scholar 

  20. Jeon C, Lee Y, Youn S, Lee H, Chung N. Factors affecting postural reduction in posterior surgery for thoracolumbar burst fracture. J Spinal Disord Tech. 2015;28(4):E225–30.

    Article  Google Scholar 

  21. Li L, Dong Y, He Y, Liu X, Tong W. Treatment of thoracolumbar fractures by percutaneous pedicle screw fixation technique combined with three-step reduction. J Neurol Surg A Cent Eur Neurosurg. 2017;78(03):231–7.

    Article  Google Scholar 

  22. Yang P, Chen K, Zhang K, Sun J, Yang H, Mao H. Percutaneous short-segment pedicle instrumentation assisted with O-arm navigation in the treatment of thoracolumbar burst fractures. J Orthop Transl. 2020;21:1–7.

    Google Scholar 

  23. Lyu J, Chen K, Tang Z, Chen Y, Li M, Zhang Q. A comparison of three different surgical procedures in the treatment of type a thoracolumbar fractures: a randomized controlled trial. Int Orthop. 2016;40(6):1233–8.

    Article  Google Scholar 

  24. Wang X, Dai L, Xu H, Chi Y. Kyphosis recurrence after posterior short-segment fixation in thoracolumbar burst fractures. J Neurosurg Spine. 2008;8(3):246.

    Article  Google Scholar 

  25. Lue YJ, Hsieh CL, Huang MH, Lin GT, Lu YM. Development of a Chinese version of the Oswestry Disability Index version 2.1. Spine (Phila Pa 1976). 2008;33(21):2354–60.

    Article  Google Scholar 

  26. Yang M, Zhao Q, Hao D, Chang Z, Liu S, Yin X. Comparison of clinical results between novel percutaneous pedicle screw and traditional open pedicle screw fixation for thoracolumbar fractures without neurological deficit. Int Orthop. 2019;43(7):1749–54.

    Article  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This work was supported by the National Natural Science Foundation of China (No. 81902213), the Medical Youth Top Talent Project of Hubei Province (No. [2019]48#), the Training Plan for Young and Middle-Aged Medical Backbone Talents in Wuhan (No. [2017]51#) and the Health Commission of Hubei Province Scientific Research Project (No. WJ2021Q054).

Author information

Authors and Affiliations

Authors

Contributions

FX and HK contributed to the study conception and design. Material preparation, data collection and analysis were performed by LLH, CJX, ZYG and QYY. The first draft of the manuscript was written by LLH. All authors read and approved the final version of the manuscript.

Corresponding authors

Correspondence to Feng Xu or Hui Kang.

Ethics declarations

Ethics approval and consent to participate

Approval was obtained from Clinical Research Ethics Committee of the General Hospital of Central Theater Command (approval number: [2021]040). Written informed consent was obtained from all patients.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no conflicts of interest.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1. MPPS mobiles in the axial plane but fixes in the sagittal plane. Thus, MPPS behaves as a fixed-axis pedicle screw in the sagittal plane and a PAPS in the axial plane.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Huang, L., Xiong, C., Guo, Z. et al. Comparison of monoplanar and polyaxial screw fixation systems in percutaneous intermediate fixation for thoracolumbar fractures. BMC Musculoskelet Disord 23, 172 (2022). https://doi.org/10.1186/s12891-022-05129-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12891-022-05129-8

Keywords