Abstract

Background

Isometric exercises for a flexed finger have been reported to be effective for treating trigger finger as the flexor tendon widens the space under the first annular (A1) pulley towards the palmar destination during the exercise. This study aimed to evaluate the structural changes during the A1 pulley stretch in healthy volunteers and patients with trigger finger using ultrasonography.

Methods

We enrolled 25 male and 14 female patients (39 middle fingers). The thickness of the subcutaneous tissue (parameter a), A1 pulley (parameter b), and the flexor tendon (parameter c) and the distance between the dorsal surface of the flexor tendon and the palmar surface of the metacarpal head (parameter d) were measured using ultrasonography of the metacarpophalangeal joint of the middle finger flexed at 45° at rest (pattern A) and under isometric contraction of the flexor tendon against an extension force of the proximal interphalangeal joint (pattern B).

Results

The average differences between patterns A and B in the healthy volunteers were 0.29 mm (parameter a; P = 0.02), 0.017 mm (parameter b; P = 0.63), 0.16 (parameter c; P = 0.26), and 0.41 (parameter d; P = 0.004), and those in patients with trigger finger were 0.22 mm (parameter a; P = 0.23), 0.019 mm (parameter b; P = 0.85), 0.03 mm (parameter c; P = 0.82), and 0.78 mm (parameter d; P < 0.001). The distance between the dorsal side of the A1 pulley and the palmar surface of the metacarpal head was also significantly increased by 0.57 mm (8.2%) in healthy volunteers (P < 0.001) and 0.81 mm (11%) in patients with trigger finger (P < 0.001).

Conclusions

In this study, the space under the A1 pulley was expanded under isometric contraction of the flexor tendon. These findings support the effectiveness of pulley stretch exercises for the trigger finger condition.

Peer Review reports

Introduction

Trigger finger is one of the most common diseases that can lead to long-term pain, deformity, and disability [1,2,3,4], in which the first annular (A1) pulley becomes stiff and thick [5]. Similarly, the tendon accompanied by synovitis [6] also becomes thick [7], which results in the A1 pulley lumen (A1PL) becoming relatively narrow for the tendon. The management of trigger finger includes both nonsurgical and surgical methods. Non-surgical treatments include the adjustment and modification of activities [8, 9], the use of orthoses and splints [10], and administration of hyaluronic acid [11] and steroid injections [12, 13]. Surgical treatment is performed either as an open or percutaneous procedure [8, 14, 15]. Orthoses and splints are associated with a reduction in the stage of stenosing tenosynovitis, the numeric pain rating scale, and the number of triggering events [10, 16]; however, they are not sufficient for complete recovery. Some drawbacks of steroid injections include pain during the procedure and the risk of tendon rupture [17]. The recurrence rate in the operated trigger finger has been reported to be as low as 0.5% [18]; however, patients may temporarily experience pain on the surgical site postoperatively [3].

As the A1PL becomes relatively narrow for the tendon with triggering, stretching the A1 pulley with an isometric contraction can be effective. Upon flexion of the metacarpophalangeal (MP) joint, the active flexor tendon contraction force and counteracting flexor tendon force can generate contact forces that expand the A1 pulley toward the palm. It has been reported that a combination of this “A1 pulley stretch” and the conventional passive extension stretch of the finger for 30 s, 10 times daily for a month, improved pain and triggering during motion in patients with trigger finger [19]. A cadaveric study reported that A1PLs expanded upon loading of the flexor tendon with the proximal interphalangeal (PIP) and MP joint fixed at a flexion angle [19]. This cadaveric study did not include patients with trigger finger, who may have a stiffer and thicker A1 pulley, thereby making it difficult to expand the A1PL [5]. To the best of our knowledge, no study has proven whether the A1 ligamentous pulley lumen is expanded in healthy volunteers and patients with trigger finger in vivo. We hypothesized that the A1 pulley stretch expands the A1PL in both healthy volunteers and patients with trigger finger. In this study, we evaluated the structural changes around the A1 pulley under isometric contraction of the flexor tendon at 45° flexion of the middle finger at rest (pattern A) and under isometric contraction of the flexor tendon resisted against the force toward the proximal interphalangeal joint extension (pattern B) in healthy volunteers and patients with trigger finger using ultrasonography.

Patients and methods

This study was conducted with the approval of the Ethics Committee at our institute (reference number: 11627) and abides by the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. Written informed consent was obtained from all the participants. Patient background information collected from the electronic charts included disease duration, number of affected fingers, and presence or absence of diabetes. A Quinnell grading system for trigger finger was used to assess the severity of the disease [20]. Only the middle finger was tested in this study. While testing using ultrasonography, the examinee was seated in front of the table facing the examiner, with the elbow flexed at 90° and the forearm supinated. An ultrasonographic device (HI VISION Avius, Hitachi Medical Corporation, Tokyo, Japan) and a 10 MHz hockey stick-type probe (EUP-054 J, Hitachi Medical Corporation, Tokyo, Japan) were used for this study (Fig. 1). Images were recorded using a long-axis view of the middle finger. The measured parameters are described below. While holding the MP joint flexed at 45° with a custom-made fixing block (pattern A), the examiner applied an ultrasonic probe onto the A1 tendon sheath and measured the thickness of the (parameter a) subcutaneous tissue, (parameter b) A1 pulley, (parameter c) flexor tendon, and (parameter d) dorsal surface of the flexor tendon to the palmar surface of the metacarpal head using a digital caliper. To retain sufficient reproducibility, measurements were performed at the thickest point of the A1 pulley to measure parameter b, and the most volar level of the metacarpal head for the other parameters a, c, and d. Subsequently, the examiner instructed the participants to perform active flexion of the PIP joint of the middle finger with the MP joint flexed at 45° to resist the passive extension load applied by the examiner on the PIP joint, thereby loading an isometric contraction of the finger flexor (pattern B) (Fig. 2). The images of the long-axis view of the middle finger during testing were recorded, and parameters a, b, c, and d were measured digitally (Figs. 3 and 4). The average distances between the dorsal surface of the A1 pulley and the palmar surface of the metacarpal head (parameter c + d), which indicated the diameter of the A1PL in patterns A and B, were compared in healthy volunteers and patients with trigger finger.

Fig. 1
figure 1

The block, which had a right-angled triangular prism shape and was made of ethylene-vinyl acetate copolymer resin, was used to maintain the finger position throughout the exercise. This fixation block was placed under the base of the proximal phalangeal bone of the middle finger, and the metacarpophalangeal joint was flexed at 45°

Fig. 2
figure 2

A hockey stick type of probe was used in this study. The examiner applied an ultrasonic probe onto the first annular (A1) tendon sheath and instructed the participants to perform active flexion of the proximal interphalangeal (PIP) joint of the middle finger isometrically to resist the passive extension load for the PIP joint applied by the examiner while keeping the metacarpophalangeal joint flexed at 45° with a custom-made fixing block

Fig. 3
figure 3

Schema of pattern B with the metacarpophalangeal joint of the middle finger flexed at 45° under isometric contraction of the flexor tendon. The examiner pushes the middle finger toward the dorsal side during the examination. An active flexor tendon contraction force and a counteracting flexor tendon force can generate contact force that expands the first annular (A1) pulley toward the palm side

Fig. 4
figure 4

Measured parameters during ultrasonographic examination on ultrasonographic image and schema. The thickness of the (parameter a) subcutaneous tissue, (parameter b) first annular (A1) pulley, (parameter c) flexor tendon, and (parameter d) dorsal surface of the flexor tendon to the palmar surface of the metacarpal head are measured using ultrasonography

We analyzed the relationship between each measurement parameter (a–d) and the patient’s background, disease duration, sex, Quinnell grade, number of affected fingers, and the presence or absence of diabetes.

The resolution of the ultrasonography with a 10 MHz probe used in this study was 0.2 mm. We evaluated intra- and inter-examiner reliability for parameter b in 10 patients, which was 0.90 (95% confidence interval [CI] 0.63–0.98) and 0.80 (95% CI 0.20–0.96), respectively.

Statistical analysis

We used the chi-square test, Student’s t-test, and paired t-test to analyze the data. A p-value less than 0.05, represented a statistically significant difference between group averages. Statistical analyses were performed using the IBM SPSS Statistics ver. 24.0 (IBM Corp., Armonk, NY, USA).

Results

Thirty-nine middle fingers of 25 males and 14 females were enrolled. The average age of the 23 healthy volunteers was 32.8 ± 7.7 (range, 27–55) years, and that of the 16 trigger finger patients was 68.6 ± 11.9 (51–86). The Quinnell grading of the patients with trigger finger was as follows: grade 1, one case; grade 2, five cases; grade 3, nine cases; and grade 5, one case. Among the 16 patients with trigger finger, four had diabetes. The descriptive characteristics of the patients with trigger fingers are shown in Table 1.

Table 1 Descriptive characteristics of the patients with the trigger finger

The means of each parameter in control cases for pattern A and pattern B are shown in Table 2.

Table 2 The means of each parameter in control cases for pattern A and pattern B

The means of each parameter in patients with a trigger finger for pattern A and pattern B are shown in Table 3.

Table 3 The mean value of each parameter in patients with trigger finger for pattern A and pattern B

The average diameter of the A1PL (c + d) in healthy volunteers for patterns A and B were 7.03 ± 0.43 mm and 7.64 ± 1.44 mm, respectively, and 7.34 ± 1.35 mm and 8.15 ± 1.59 mm, respectively, in patients with trigger finger. The average diameter of A1PL significantly expanded by 0.57 mm (mean percentage expansion of A1PL: 100 × parameter c + d in pattern B/parameter c + d in pattern A, 8.2%) in healthy volunteers (P < 0.001), and 0.81 mm (11%) in patients with trigger finger (P < 0.001) (Fig. 5). There was no significant difference between healthy volunteers and patients with trigger finger in terms of the difference in parameter c + d (P = 0.141).

Fig. 5
figure 5

The mean distances of parameter c + d on pattern A and pattern B in each healthy volunteers and patients with trigger finger are shown. Error bars indicate standard deviation

We analyzed the relationship between each measurement parameter (a–d) and disease duration, sex, Quinnell grade, number of affected fingers, and the presence or absence of diabetes. Among these variables, only sex was associated with parameter c (p = 0.003) and parameter c + d using multivariate analysis (P = 0.03, R2 = 0.40).

Discussion

In this study, we measured and evaluated the structural changes around the A1 pulley caused by applying an active isometric bending force to a finger flexed at 45° at the MP joint in 23 healthy volunteers and 16 patients with trigger finger using ultrasonography. The average diameters of A1PL significantly increased by 0.57 mm in healthy volunteers and 0.81 mm in patients with trigger finger. This study demonstrated that isometric contraction of the flexor tendon increased the space under the A1 pulley in both healthy volunteers and patients with trigger finger. The mean percentage expansion of A1PL was 8.2% in healthy volunteers and 11% in patients with trigger finger, and while the mean percentage expansion was not very large, these enlargements of the A1PL could improve the stiffness, pain, or catching. A previous study revealed that a strain over 2.0–4.0% resulted in permanent deformation in horse and human tendons [21]. Histological studies on specimens strained to the 1.0, 2.0, 3.0, and 4.0% levels indicate that above the 2.0–3.0% strain level, not all the collagen fibers return to their original unstrained wave pattern. Abrahams et al. also concluded that the stress relaxation phenomenon for the tendon was essentially the same as that observed for other connective tissues.

Miyamoto et al. reported that the stiffness of the A1 pulley in patients with trigger finger was more than that in healthy volunteers [5]. However, in this study, the mean percentage expansion of A1PL was 8.2% in healthy volunteers and 11% in patients with trigger finger. A relatively smaller value of parameter d and a larger tendon diameter in patients with trigger finger in pattern A than that of healthy volunteers could affect the mean percentage expansion of A1PL in both the groups in this study.

To take measurements of all patients easily under the same conditions and increase the reproducibility of this study, we evaluated the expansion of the A1 pulley under isometric contraction of the flexor tendon at the MP joint flexed at 45°. Applying isometric contraction with a more flexed angle of the MP joint may increase the force vector in the direction of expanding the A1PL through the flexor tendon. In clinical practice, it may be more efficient to expand the A1 pulley if the MP joint can be flexed more and the PIP joint can be flexed.

Parameter c of female patients with trigger finger was significantly smaller than that of male patients. These results could be explained by the smaller cross-sectional area of the tendon in females than in males [22, 23].

Parameter a increased significantly upon isometric contraction of the flexor tendon in healthy volunteers. In contrast, there was no difference in it in patients with trigger finger. Even during isometric contraction of the flexor tendon, it could move slightly to the volar side. Volar side shift of the flexor tendon could occur, especially in the distal part of the flexor tendon from the A1 pulley, which could make subcutaneous fat above the A1 pulley slightly redundant and thick. We assumed that parameter a increased owing to the deformation of subcutaneous fat by pressure from the isometrically contracting flexor tendon. Patients with trigger finger have relatively stiffer A1 pulleys; therefore, we assume that parameter a was less affected by isometric contraction of the flexor tendon.

There were no patients with diabetes among the 23 healthy volunteers, and four of the 16 patients with trigger finger were included in this study. Previous estimates of the prevalence of trigger finger in the diabetic population ranged from 5 to 20%, compared with 1–2% in the general population [24]. Patients with diabetes are predisposed to developing trigger fingers compared to the general population. Their symptoms tend to be severe, and multiple fingers are affected bilaterally [24]. However, the use of corticosteroid injections shows a high recurrence rate of trigger finger in diabetic patients [25], while repetitive corticosteroid injections increases the risk of tendon rupture. Moreover, corticosteroid injections can increase blood glucose concentration in patients with diabetes [26]. It may be particularly beneficial for these patients to relieve symptoms by enlarging the A1PL using the A1 pulley stretch.

The limitation of this study is that the stretching effect of the A1 pulley is likely to be enhanced in the MP joint deep flexion and PIP joint flexion positions; however, this was not performed in this study. As mentioned earlier, it is still difficult to obtain an ultrasonic image when the MP joint is deeply flexed, even when using a hockey stick probe. However, we believe that the results of this study are sufficient to understand the effect of MP joint flexion with isometric contraction of the flexor tendon on the expansion of the A1 pulley lumen. Second, it is unclear if the repetitive expansion of th A1PL is retained over a long period. Regardless, tentative expansion of the A1PL appears to have a positive impact on the symptoms of trigger finger. Third, the measurer was not blinded to the group to which the participants belonged to, possibly affecting the results due to experimenter bias.

Conclusion

We suggest that isometrically applying a flexing force to the finger could expand the A1PL, which is a common site for stenosis of the trigger finger in both healthy volunteers and patients with trigger finger.

Availability of data and materials

The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

A1PL:

A1 pulley lumen

MP:

Metacarpophalangeal

PIP:

Proximal interphalangeal

References

  1. Akhtar S, Bradley MJ, Quinton DN, Burke FD. Management and referral for trigger finger/thumb. BMJ. 2005;331(7507):30–3. https://doi.org/10.1136/bmj.331.7507.30.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Eastwood DM, Gupta KJ, Johnson DP. Percutaneous release of the trigger finger: an office procedure. J Hand Surg Am. 1992;17(1):114–7. https://doi.org/10.1016/0363-5023(92)90125-9.

    Article  CAS  PubMed  Google Scholar 

  3. Fiorini HJ, Tamaoki MJ, Lenza M, Gomes Dos Santos JB, Faloppa F, Belloti JC. Surgery for trigger finger. Cochrane Database Syst Rev. 2018;2:CD009860.

    PubMed  Google Scholar 

  4. Langer D, Luria S, Michailevich M, Maeir A. Long-term functional outcome of trigger finger. Disabil Rehabil. 2018;40(1):90–5. https://doi.org/10.1080/09638288.2016.1243161.

    Article  PubMed  Google Scholar 

  5. Miyamoto H, Miura T, Isayama H, Masuzaki R, Koike K, Ohe T. Stiffness of the first annular pulley in normal and trigger fingers. J Hand Surg Am. 2011;36(9):1486–91. https://doi.org/10.1016/j.jhsa.2011.05.038.

    Article  PubMed  Google Scholar 

  6. Uchihashi K, Tsuruta T, Mine H, Aoki S, Nishijima-Matsunobu A, Yamamoto M, et al. Histopathology of tenosynovium in trigger fingers. Pathol Int. 2014;64(6):276–82. https://doi.org/10.1111/pin.12168.

    Article  CAS  PubMed  Google Scholar 

  7. Sato J, Ishii Y, Noguchi H, Takeda M. Sonographic appearance of the flexor tendon, volar plate, and A1 pulley with respect to the severity of trigger finger. J Hand Surg Am. 2012;37(10):2012–20. https://doi.org/10.1016/j.jhsa.2012.06.027.

    Article  PubMed  Google Scholar 

  8. Giugale JM, Fowler JR. Trigger finger: adult and pediatric treatment strategies. Orthop Clin North Am. 2015;46(4):561–9. https://doi.org/10.1016/j.ocl.2015.06.014.

    Article  PubMed  Google Scholar 

  9. Ryzewicz M, Wolf JM. Trigger digits: principles, management, and complications. J Hand Surg Am. 2006;31(1):135–46. https://doi.org/10.1016/j.jhsa.2005.10.013.

    Article  PubMed  Google Scholar 

  10. Drijkoningen T, van Berckel M, Becker SJE, Ring DC, Mudgal CS. Night splinting for idiopathic trigger digits. Hand (N Y). 2018;13(5):558–62. https://doi.org/10.1177/1558944717725374.

    Article  Google Scholar 

  11. Kanchanathepsak T, Pichyangkul P, Suppaphol S, Watcharananan I, Tuntiyatorn P, Tawonsawatruk T. Efficacy comparison of hyaluronic acid and corticosteroid injection in treatment of trigger digits: a randomized controlled trial. J Hand Surg Asian Pac Vol. 2020;25(1):76–81. https://doi.org/10.1142/S2424835520500101.

    Article  PubMed  Google Scholar 

  12. Peters-Veluthamaningal C, van der Windt DA, Winters JC, Meyboom-de Jong B. Corticosteroid injection for trigger finger in adults. Cochrane Database Syst Rev. 2009;(1):CD005617. https://doi.org/10.1002/14651858.CD005617.pub2.

  13. Dala-Ali BM, Nakhdjevani A, Lloyd MA, Schreuder FB. The efficacy of steroid injection in the treatment of trigger finger. Clin Orthop Surg. 2012;4(4):263–8. https://doi.org/10.4055/cios.2012.4.4.263.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Matthews A, Smith K, Read L, Nicholas J, Schmidt E. Trigger finger: an overview of the treatment options. JAAPA. 2019;32(1):17–21. https://doi.org/10.1097/01.JAA.0000550281.42592.97.

    Article  PubMed  Google Scholar 

  15. Huisstede BM, Hoogvliet P, Coert JH, Friden J, European HG. Multidisciplinary consensus guideline for managing trigger finger: results from the European HANDGUIDE study. Phys Ther. 2014;94(10):1421–33. https://doi.org/10.2522/ptj.20130135.

    Article  PubMed  Google Scholar 

  16. Colbourn J, Heath N, Manary S, Pacifico D. Effectiveness of splinting for the treatment of trigger finger. J Hand Ther. 2008;21(4):336–43. https://doi.org/10.1197/j.jht.2008.05.001.

    Article  PubMed  Google Scholar 

  17. Rosenbaum YA, Benvenuti N, Yang J, Ruff ME, Awan HM, Samora JB. The effect of trigger finger injection site on injection-related pain. Hand (N Y). 2018;13(2):164–9. https://doi.org/10.1177/1558944717703134.

    Article  Google Scholar 

  18. Strigelli V, Mingarelli L, Fioravanti G, Merendi G, Merolli A, Fanfani F, et al. Open surgery for trigger finger required combined a1-a2 pulley release. A retrospective study on 1305 case. Tech Hand Up Extrem Surg. 2019;23(3):115–21. https://doi.org/10.1097/BTH.0000000000000231.

    Article  PubMed  Google Scholar 

  19. Yamazaki A, Matsuura Y, Kuniyoshi K, Suzuki T, Akasaka T, Ozone E, et al. A1 pulley stretching treats trigger finger: A1 pulley luminal region under digital flexor tendon traction. Clin Biomech (Bristol, Avon). 2020;72:136–40.

    Article  Google Scholar 

  20. Quinnell RC. Conservative management of trigger finger. Practitioner. 1980;224(1340):187–90.

    CAS  PubMed  Google Scholar 

  21. Abrahams M. Mechanical behaviour of tendon in vitro. A preliminary report. Med Biol Eng. 1967;5(5):433–43. https://doi.org/10.1007/BF02479137.

    Article  CAS  PubMed  Google Scholar 

  22. Sarver DC, Kharaz YA, Sugg KB, Gumucio JP, Comerford E, Mendias CL. Sex differences in tendon structure and function. J Orthop Res. 2017;35(10):2117–26. https://doi.org/10.1002/jor.23516.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  23. Treme G, Diduch DR, Billante MJ, Miller MD, Hart JM. Hamstring graft size prediction: a prospective clinical evaluation. Am J Sports Med. 2008;36(11):2204–9. https://doi.org/10.1177/0363546508319901.

    Article  PubMed  Google Scholar 

  24. Kuczmarski AS, Harris AP, Gil JA, Weiss AC. Management of diabetic trigger finger. J Hand Surg Am. 2019;44(2):150–3. https://doi.org/10.1016/j.jhsa.2018.03.045.

    Article  PubMed  Google Scholar 

  25. Wojahn RD, Foeger NC, Gelberman RH, Calfee RP. Long-term outcomes following a single corticosteroid injection for trigger finger. J Bone Joint Surg Am. 2014;96(22):1849–54. https://doi.org/10.2106/JBJS.N.00004.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Catalano LW 3rd, Glickel SZ, Barron OA, Harrison R, Marshall A, Purcelli-Lafer M. Effect of local corticosteroid injection of the hand and wrist on blood glucose in patients with diabetes mellitus. Orthopedics. 2012;35(12):e1754–8. https://doi.org/10.3928/01477447-20121120-20.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

None.

Financial interest, COI

The authors declared no potential conflicts of interest and funding with respect to the research, authorship, and/or publication of this article.

Funding

No funds were received in support of this work. No benefits in any form have been or will be received from a commercial party related directly or indirectly to the subject of this manuscript.

Author information

Authors and Affiliations

Authors

Contributions

ST and KU conceived and designed the study; ST, KU, RS, TM, TO, TS and YM performed the study and collected the data; ST and KU performed statistical analysis of the data and interpreted the results; ST and KU wrote the manuscript; All authors read and approved the final manuscript.

Corresponding author

Correspondence to Kosuke Uehara.

Ethics declarations

Ethics approval and consent to participate

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research regulations, and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. Written informed consent was obtained from all participants, and all study protocols were approval of the institutional review board of graduate school of Medicine and faculty of Medicine, the university of Tokyo (approval number 11627).

Consent for publication

Not applicable.

Competing interests

No benefits in any form have been or will be received from any commercial party related directly or indirectly to the subjects of this article. The authors declare that they have no competing interest to disclose.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tanaka, S., Uehara, K., Sugimura, R. et al. Evaluation of the first annular pulley stretch effect under isometric contraction of the flexor tendon in healthy volunteers and trigger finger patients using ultrasonography. BMC Musculoskelet Disord 22, 421 (2021). https://doi.org/10.1186/s12891-021-04299-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12891-021-04299-1

Keywords