Skip to main content

Table 4 Comparison of the ROM of the complete finite element model in the present study with data from other studies (degree)

From: Biomechanical evaluation of different oblique lumbar interbody fusion constructs: a finite element analysis

Model

Flexion + Extension

Bending

Rotation

Kamal et al

12.15

5.80

2.82

Biswas et al

12.1

5.3

2.4

Pearcy and Tibrewal

13

5

1.5

Si-segment FEM

13.8

5.2

2.05

Do-segment FEM

14.3

5.1

2.0