Skip to main content

Table 9 The diagnostic performance of different serum parameters for PJI (Knee Joint Subgroup)

From: Limited value of platelet-related markers in diagnosing periprosthetic joint infection

Biomarker

AUC (95%CI)

Youden index

Optimal cutoff value

Sensitivity (%)

Specificity (%)

CRP (mg/L)

0.845(0.745–0.946)

0.6333

3.60

83.33

80.00

ESR (mm/h)

0.882(0.773–0.990)

0.7458

22.00

89.58

85.00

PC/CRP

0.822(0.721–0.923)

0.5250

20.60

62.50

90.00

PC/AGR

0.792(0.667–0.916)

0.5250

160.63

87.50

65.00

PLR

0.768(0.645–0.891)

0.4708

132.57

77.08

70.00

PC (× 109/L)

0.670(0.525–0.816)

0.3167

184

91.67

40.00

PVR

0.639(0.491–0.786)

0.2458

19.89

89.58

35.00

PNR

0.583(0.436–0.730)

0.2458

67.13

64.58

60.00

MPV

0.505(0.353–0.656)

0.2042

9.10

60.42

60.00