From: Finite element analysis and a pilot study of different fixation constructs for Danis-Weber A and B lateral malleolus fractures
Component name
Young’s modulus (MPa)
Poisson’s ratio
References
Fibula cortical bone
7300
0.30
[21]
Fibula cancellous bone
1100
0.26
[20]
Plate
110000
[19, 20, 23]
Screw (Ti-6Al-4Â V)
113800
0.34
[18, 24]