Skip to main content

Table 2 Comparison of perioperative data of patients between the two groups

From: Hemostatic effect and safety evaluation of oxidized regenerated cellulose in total knee arthroplasty- a randomized controlledtrial

 

Control Group

(n = 35)

ORC Group

(n = 35)

P value

TBL(ml)

1052.25 ± 308.44

902.32 ± 307.82

0.046

Hb drop(g/L)

32.29 ± 10.28

28.63 ± 11.19

0.159

IBL(ml)

102.29 ± 14.47

100.71 ± 14.51

0.651

HBL(ml)

949.96 ± 297.59

801.61 ± 298.80

0.041

Operation time(min)

91.4 ± 15.19

89.77 ± 13.46

0.636

  1. TBL: total blood loss. IBL: intraoperative blood loss. HBL: hidden blood loss