Skip to main content

Table 2 Anesthesia method, Operation time, Blood loss, Intraoperative blood Transfusion, and Intraoperative fluoroscopy times

From: The comparison of the Effect of double reverse traction repositor (DRTR) and traction table assisted Anterograde Intramedullary nail in treatment of femoral shaft fractures

 

Total patient(n = 44)

DRTR

(n = 23)

Traction table (n = 21)

P value

Anesthesia (%)

   

0.599a

General

31 (70.5)

17 (73.9)

14 (66.7)

 

Spinal

13 (29.5)

6 (26.1)

7 (33.3)

 

Set up time, mean ± SD

43.75 ± 13

40.65 ± 12.5

47.1 ± 13

0.09c

Procedure time, mean ± SD

208.1 ± 63.5

207.1 ± 44.6

209.0 ± 80.6

0.65c

Anesthesia time, mean ± SD

261.8 ± 58.8

254.0 ± 38.8

270.1 ± 74.9

0.564c

Blood loss, mean ± SD

311.3 ± 219.3

269.6 ± 184.4

357.1 ± 248.6

0.189d

Intraoperative fluoroscopy times, mean ± SD

18.9 ± 5.2

15.0 ± 3.0

23.1 ± 3.6

<0.001d

The quality of reduction (%)

   

0.544a

Anatomic

29 (65.9)

17 (73.9)

12 (57.1)

 

Acceptable

9 (20.4)

4 (17.4)

5 (23.8)

 

Poor

6 (13.7)

2 (8.7)

4 (19.1)

 

Open reduction (%)

10 (22.7)

2 (8.7)

8 (38.0)

0.02b

  1. (a) Pearson Chi-Square test; (b) Fisher exact test; (c) Mann-Whitney U test; (d) Student t test