Skip to main content
Fig. 2 | BMC Musculoskeletal Disorders

Fig. 2

From: Biomechanical effects of internal fixation with self-lock compression anti-rotation blade for Pauwels type III femoral neck fractures: a comparative finite element analysis

Fig. 2

Finite element models of Pauwels type III FNF with internal fixations: (a) the inverted triangular parallel cannulated screw (3CS) model, (b) the biplane double-supported screw fixation (BDSF) model, (c) the SCAB combined with cannulated screw (SCAB + CS) model, (d) a sample mesh for the fractured bone, (e) details of applied loads of proximal femur