Skip to main content

Table 3 Overview of clamps as a comprehensive catalogue

From: Categorize the existing clamps used for tensile test of human graft– a systematic review

Name of clamp

References

Type of clamp

Type of endurance test

Pre-

loading type

Type of tendon

Measured and calculated parameters

Metal U-shaped frames

47, 50

room temperature

static

dynamic

sheep patellar tendon

failure stress, failure strain, normalized stiffness, energy to failure

Custom designed clamps

67

room temperature

static

static

canine patella-ligament-tibia

failure load, stiffness

Factory clamps

36

room temperature

dynamic

dynamic

human patellar tendon

ultimate elongation, ultimate stress, ultimate stiffness

Wedge shaped factory-clamps

42

room temperature

dynamic

static

achilles

maximum stress, maximum strain, modulus

Wedge-grip clamps

34, 38

room temperature

dynamic

dynamic

human patellar tendon

failure load, stiffness

Aluminum grips with polymer liners

40, 59, 60

room temperature

dynamic

dynamic

human patellar tendon

failure load, stiffness, strain

Testing configuration for single-strand and double-strand

32, 69

cooled temperature

static and dynamic

dynamic

tibialis anterior and posterior

linear stiffness, ultimate tensile force, tensile modulus, ultimate tensile strength, ultimate tensile strain

Custom designed clamps with dry ice chamber

28

cooled temperature

dynamic

dynamic

anterior and posterior tibialis

failure load, failure stress, stiffness

Factory clamps with dry ice chamber

56

cooled temperature

dynamic

dynamic

achilles, quadriceps, semitendinosus + gracilis, tibialis anterior, peroneus longus

Young’s modulus of elasticity, maximum load, strain at tensile strength, strain at break

Clamp with thermocouple

37

heated temperature

dynamic

dynamic

bilateral patellar tendon

tensile strength, tensile modulus

Custom clamp in testing chamber

57

heated temperature

static and dynamic

static and dynamic

human patellar tendon

stiffness, maximum load

Custom clamp in biochamber

70

heated temperature

dynamic

dynamic

soleus tendon

ultimate tensile stress, elastic modulus, toughness