Skip to main content

Table 5 Results of multivariate regression analysis

From: Hidden blood loss of total knee arthroplasty in hemophilia arthritis: an analysis of influencing factors

Variable

B value

B standard error

B standardized value

T value

P value

intercept

1426.303

226.473

6.298

<0.001

TXA interventiona

−395.806

49.281

−0.582

−8.032

<0.001

FVIII prophylaxisb

−130.529

47.720

−0.186

−2.735

0.008

age

8.884

2.648

0.227

3.354

<0.001

incremental IVR

−164.983

68.014

−0.154

−2.426

0.017

  1. awithout TXA as control