Skip to main content

Table 1 Summary of biomechanical result

From: Distal interphalangeal joint arthrodesis with nonaxial multiple small screws: a biomechanical analysis with axial headless compression screw and clinical result of 15 consecutive cases

 

AHCS specimens (n = 10)

NMSS specimens (n = 10)

p

Bending stiffness (N/mm) a

23.0 (7.7)

31.6 (17.2)

0.16

Bending load to failure (N) a

72.2 (24.0)

97.4 (26.4)

0.009

 

AHCS specimens (n = 7)

NMSS specimens (n = 7)

 

Torsional stiffness (Nm/degrees) a

0.029 (0.013)

0.062 (0.029)

0.026

Torque to failure (Nm) a

0.41 (0.1)

0.99 (0.46)

0.018

  1. AHCS axial headless compression screw, NMSS nonaxial multiple small screw
  2. a paired t test. Mean ± SD presented
  3. Statistically significant