Table 3 Interventions’ effect comparison

From: Effectiveness of the Fixtoe Device® in plantar pressure reduction: a preliminary study

  Pmax (Kpa) P–T (Kpa/s)
Cohen’s d 95% CI p-value Cohen’s d 95% CI p-value
Stabilizing Tape vs. Fixtoe Device® - 41.2 (± 6.5) 1.45 0.81 – 2.08  < .0001 - 8.8 (± 1.2) 1.86 1.19 – 2.54  < .0001
Stabilizing Tape vs. Fixtoe Device® w/metatarsal pad - 60.0 (± 6.9) 2.36 1.62 – 3.1  < .0001 - 11.9 (± 1.3) 2.53 1.77 – 3.28  < .0001
Fixtoe Device® vs. Fixtoe Device® w/metatarsal pad - 18.9 (± 5.3) 0.82 0.23 – 1.41 .005 - 3.1 (± 0.9) 0.68 0.1 – 1.26 .009
  1. Pmax Maximal pressure, ∆ mean difference, 95% CI 95% Cohen’s d confidence interval, P/T pressure–time integral. Mean (± SEM)