Skip to main content

Table 3 Packed red blood cell transfusion, Hospital stays, Time to receive X-ray film, Time to Apply binder

From: Benefits of early application of pelvic circumferential compression device to reduce bleeding in pelvic fractures

Outcomes

Early pelvic binder case

Conventional pelvic binder case

Mean diff.

95% CI

p-value

Mean (SD)

Mean (SD)

n = 15

n = 15

Packed red blood cell transfusion

0.80 ± 1.42

2.4 ± 2.32

0.008a

Hospital stays (day)

12 (8,15)

11 (8, 16)

− 1.00

−7.00 - 10.00

0.803a

Time to receive X-ray film (min)

33.33 ± 9.07

32.73 ± 12.93

0.60

−7.75 - 8.95

0.884b

Time to Apply binder (min)

16.40 ± 5.45

40.40 ± 13.64

−24.00

− 31.77 - -16.24

< 0.001b

  1. SD Standard deviation, Mean diff. Mean difference
  2. aMann Whitney U Test
  3. bindependent t-test