Table 3 Performance of 3D-MEDIC and 2D-PD fs with reference to shoulder arthroscopy

From: Diagnostic performance of 3D-multi-Echo-data-image-combination (MEDIC) for evaluating SLAP lesions of the shoulder

 

Sensitivity

Specificity

PPV

NPV

3D-MEDIC – reader 1

100.0% (71.5–100.0%)

50.0% (11.8–88.2%)

78.6% (49.2–95.3%)

100.0% (29.2%-100.0)

3D-MEDIC – reader 2

100.0% (71.5–100.0%)

66.7% (22.3–95.7%)

84.6% (54.6–98.1%)

100.0% (39.8–100.0%)

2D-PD fs – reader 1

90.9% (58.7–99.8%)

83.3% (35.9–99.6%)

90.9% (58.7–99.8%)

83.3% (35.9–99.6%)

2D-PD fs – reader 2

100.0% (71.5–100.0%)

83.3% (35.9–99.6%)

91.7% (61.5–99.8%)

100.0% (47.8–100.0%)

  1. 3D-MEDIC three dimensional Multi Echo Data Image Combination, PD Proton density, fs fat saturated, PPV Positive predictive value, NPV Negative predictive value. 95% confidence interval is depicted in parentheses.