Skip to main content

Table 4 Comparison of perioperative parameters between isthmic and non-isthmic nonunion subgroups

From: Augmentative antirotational plating provided a significantly higher union rate than exchanging reamed nailing in treatment for femoral shaft aseptic atrophic nonunion - retrospective cohort study

Parameter

AAP

ERN

P value

Isthmic nonunion

No. of patients

13

50

 

 Union

11

33

0.19

 Nonunion

2

17

Union time, mean ± SD, mo

8.27 ± 4.82

10.33 ± 5.27

0.26

Operating time, mean ± SD, min

117.5 ± 35.94

164.84 ± 62.98

0.015

Intraoperative blood loss, mean ± SD, mL

288.46 ± 267.05

237 ± 246.16

0.51

Non-isthmic nonunion

No. of patients

13

20

 

 Union

12

12

0.04

 Nonunion

1

8

Union time, mean ± SD, mo

6.92 ± 2.81

9.17 ± 5.80

0.24

Operating time, mean ± SD, min

139.25 ± 40.32

181.05 ± 71.70

0.075

Intraoperative blood loss, mean ± SD, mL

211.00 ± 134.09

270.00 ± 206.73

0.37