Skip to main content

Table 5 Postoperative recovery and complications in the four groups

From: Efficacy of internal fixation with mini plate and internal fixation with hollow screw for Regan-Morrey type II and III ulna coronoid fractures

 

Mini plate group (n = 31)

Hollow screw group (n = 44)

Kirschner wire group (n = 62)

Steel wire suture group (n = 27)

Fracture healing time (week)

10.1 ± 1.3

10.8 ± 1.0

13.4 ± 1.3*#

13.0 ± 1.6*#

elbow flexion and extension (°)

114.6 ± 6.5

115.4 ± 8.1

95.7 ± 8.1*#

94.4 ± 7.7*#

forearm rotation (°)

126.0 ± 7.3

127.7 ± 6.0

103.9 ± 4.2*#

102.5 ± 3.8*#

Incidence of complications

0 (0%)

2 (4.55%)

20 (32.26%)*#

10 (37.04%)*#

  1. Notes: measurement data or counting data were presented as mean ± standard deviation or number of cases; one-way analysis of variance (ANOVA) with replicate measurement or chi square test were used to compare multi-group data
  2. * vs. the mini plate group, p < 0.05; # vs. the hollow screw group, p < 0.05