Skip to main content

Table 1 Summary of intra- and intertester reliability studies for range of motion on both the affected and the non-affected shoulders using different measuring modalities

From: Passive range of motion in patients with adhesive shoulder capsulitis, an intertester reliability study over eight weeks

Authors

Study sample & Size (N)

Movement

Side measured affected/ non-affected

Measuring instrument

Point estimates or over time

Study type

ICC

Sw

Pandya et al. [19]

Muscular dystrophy N = 150

PROM: ABD

Affected

Goniometer

Point estimates

Inter-tester & intra-tester

0.67

No

Riddle et al.[8]

Shoulder pain N = 100, two groups of 50 each

PROM: ABD

Affected

Goniometer

Point estimates

Inter-tester & intra-tester

0.87

No

PROM: ER

0.88

PROM: IR

0.55

Croft et al. [21]

Shoulder complaints N = 6

PROM: EL

Affected

Protractor

Point estimates

Inter-tester

0.95

No

PROM: ER

Affected

 

0.43

Green et al.[16]

Shoulder pain & stiffness N = 6

AROM: FLEX, ABD, ER, IR, HBB

Affected

Plurimeter

Point estimates

Inter-tester & intra-tester

0.62–0.95

No

Sabari et al. [14]

Rehab.patients N = 11

AROM: FLEX, ABD

Mixed

Goniometer

Point estimates

Intra-tester

0.73–0.78

No

Normal N = 19

PROM: FLEX, ABD

0.78–0.81

MacDermid et al. [9]

Shoulder pathology

PROM: ER

Affected

Goniometer

Point estimates

Inter-tester & intra-tester

0.85 & 0.80

Yes

N = 34

Hayes et al. [10]

Shoulder pathology

AROM: ABD

Affected

Goniometer, visual est., photography

Point estimates

Inter-tester & intra-tester

ICC(Rho) 0.69

Yes

N = 8

AROM:ER

Affected

Goniometer

0.64

AROM: HBB

Measuring tape

0.39

Hoving et al. [22]

Shoulder pain & stiffness N = 6

AROM: ABD

Affected

Plurimeter

Point estimates

Inter-tester & intra-tester

0.51

No

ER in neutral

0.29

ER in abd

0.11

IR in abd

0.06

HBB

0.80

Awan et al. [23]

Normal (athletes) N = 56

ER without scapular stabilization

Unaffected, right & left side

Digital inclinometer

Point estimates

Inter-tester/ intra-tester

0.41–0.51

No

IR standard technique

0.50–0.66

IR with scap.stab.

IR without scap. stab

de Winter et al. [17]

Shoulder complaints N = 155

PROM: ABD

Affected/ non-affected

Digital inclinometer

Point estimates

Inter-tester

0.83/0.28

No

PROM: ER

0.90/0.56

Terwee et al. [20]

Shoulder complaints N = 201

PROM: ABD

Affected/ non-affected

Visual estimation

Point estimates

Inter-tester

0.67/0.15

Yes

AROM: EL

0.88/0.76

PROM: ER

0.73/0.34

Nadeau et al. [12]

Normal N = 30

AROM: ELEV, PROTR, RETRAC

Non-affected

Goniometer & tape measure

Point estimates

Inter-tester & intra-tester

0.78–0.46

No

0.75–0.32

Tveitå et al. [15]

Shoulder adhesive capsulitis N = 32

PROM: ABD

Affected/non-affected

Digital inclinometer

Point estimates

Intra-tester

0.72/0.89

Yes

FLEX

0.76/0.61

IR

0.81/0.88

ER

0.91/0.86

Mullaney et al. [13]

Shoulder pain N = 20

AROM: FLEX

Affected/non-affected

Goniometer/ digital level

Point estimates

Inter-tester & intra-tester

0.93/0.74, 0.92/0.79, 0.82/0.62

Yes

ER

IR

Kolber et al. [11]

Normal N = 30

AROM: ABD

Non-affected

Inclinometer

Point estimates

Inter-tester & intra-tester

0.95

Yes

AROM: ER

Non-affected

0.88

AROM: IR

0.93

De Jong et al. [24]

Hemiplegic shoulder N = 43

PROM: ABD

Affected

Hydro-goniometer

Over time 4, 8 & 20 weeks

Inter-tester

0.97

Yes

PROM: ER

Affected

0.94

  1. ABD = abduction, ER = external rotation, IR = internal rotation, HBB = hand behind back, EL = elevation, PROM = Passive range of motion, AROM = Active range of motion, Sw = standard error of measurement, scap. stab = scapular stabilization.