Table 4 Multivariate binary logistic regression analysis results

From: Construction of a nomogram model for deep vein thrombosis in patients with tibial plateau fracture based on the Systemic Inflammatory Response Index

Variable

OR[95%CI]

p

NC

 

< 0.001

 ≤ 7.6

1

 

 > 7.6

7.036[3.516–14.080]

 

LYM

 

0.040

 ≤ 1.7

1

 

 > 1.7

0.507[0.265–0.969]

 

SIRI

 

0.037

 ≤ 3.95

1

 

 > 3.95

2.090[1.044–4.182]