Skip to main content

Table 3 Surgical effect and image quality were evaluated in each group

From: Comparing the effectiveness of 3D printing technology in the treatment of clavicular fracture between surgeons with different experiences

Dose group

A

B

C

D

P

operation time (min)

103.65 ± 26.94

83.60 ± 19.30

117.50 ± 26.75

102.50 ± 25.31

0.01

blood loss (ml)

24.00 ± 14.74

17.25 ± 10.82

31.50 ± 21.34

27.00 ± 10.81

0.01

Length of incision(cm)

6.36 ± 2.37

7.25 ± 1.97

9.80 ± 1.61

9.15 ± 1.84

0.01

number of Intraoperative fluoroscopy (n)

5.95 ± 1.05

5.25 ± 0.97

13.85 ± 3.05

9.25 ± 2.27

0.01

CT image quality assessment (fraction)

4.40 ± 0.60

5.00 ± 0.01

5.00 ± 0.01

5.00 ± 0.01

0.01

3D fracture model(fraction)

4.95 ± 0.224

5.00 ± 0.01

5.00 ± 0.01

5.00 ± 0.01

0.30