Skip to main content

Table 1 The general demographic information and reoperation rate of the two groups

From: Reoperation rate and implants’ position variation features of displaced femoral neck fractures with sliding compression or length-stable fixation in young and middle-aged population

 

Sliding compression fixation

(n = 110)

Length-stable fixation

(n = 105)

P value

Age (yr)

53.75 ± 11.94a

51.23 ± 11.81

0.121

Gender

 Male

45(40.9)

71(67.6)

0.000

 Female

65(59.1)

34(32.4)

 

Pauwels > 50

70(63.6)

72(68.6)

0.445

Reoperation

8(7.3)

25(23.8)

0.001

 Non-union

2(1.8)

12(11.4)

0.004

 Joint penetration

4(3.6)

10(9.5)

0.080

 Soft tissue irritation

2(1.8)

3(2.9)

0.613

Femoral neck

shortening (mm)

6.58 ± 3.18

4.16 ± 3.65

0.022

  1. *Data are presented as the number of patients, with the percentage in parentheses, unless otherwise noted. aStandard deviation