Skip to main content

Table 2 Biomechanical properties of the three fixation techniques

From: Biomechanical analysis of two medial buttress plate fixation methods to treat Pauwels type III femoral neck fractures

  Group A Group B P
Failure load (N) 1968.09 (227.29) 1911.86 (215.55) 0.669
Stiffness(N/mm) 399.94 (91.20) 390.70 (104.99) 0.842
  1. Mean values are given along with one standard deviation in parentheses