Skip to main content

Table 5 Stiffness and stress distribution of intact model and different postoperative fusion models

From: Finite analysis of stability between modified articular fusion technique, posterior lumbar interbody fusion and posteriorlateral lumbar fusion

Model

Stiffness (N/mm)

Maximum Fusion Site Stress (MPa)

Maximum Internal Stress (MPa)

Intact Model

29.2 ± 2.1

PLF Model

56.9 ± 5.2

136.8 ± 4.5

210.1 ± 8.3

PLIF Model

63.3 ± 5.5

180.7 ± 3.7

83.3 ± 7.5

Modified articular fusion model

53.1 ± 4.6

186.1 ± 3.1

194.8 ± 10.2