From: Applicable safety analysis and biomechanical study of iliosacral triangular osteosynthesis
Materials | Young’s modulus (MPa) | Poisson’s ratio(u) | Reference | ligament | Stiffness (N/mm) | Number of elements | Reference |
---|---|---|---|---|---|---|---|
Titanium screw/rod/plate | 110,000 | 0.3 | [24] | Anterior sacroiliac ligament | 700 | 10 × 2 | [25] |
Cortical bone (Pelvis) | 17,000 | 0.3 | [23] | Posterior sacroiliac ligament (long) | 1000 | 4 × 2 | [25] |
Cancellous bone (Pelvis) | 100 | 0.2 | [23] | Posterior sacroiliac ligament (short) | 400 | 10 × 2 | [25] |
Cortical bone (Lumbar) | 12,000 | 0.3 | [23] | Interosseous sacroiliac ligament | 2800 | 4 × 2 | [25] |
Cancellous bone (Lumbar) | 100 | 0.2 | [23] | Sacrospinous ligament | 1400 | 5 × 2 | [25] |
Posterior bony elements | 3500 | 0.25 | [24] | Sacrotuberous ligament | 1500 | 5 × 2 | [25] |
Articular cartilage | 10 | 0.4 | [24] | Superior pubic ligament | 500 | 1 × 1 | [25] |
Bony endplate | 1000 | 0.4 | [24] | Accurate pubic ligament | 500 | 1 × 1 | [25] |
Cartilage endplate | 25 | 0.25 | [24] | Iliolumbar ligament | 1000 | 4 × 2 | [25] |
Nucleus pulposus | 1 | 0.499 | [24] | Â | Â | Â | Â |
Matrix of annulus fibrosus | 4.2 | 0.45 | [24] | Â | Â | Â | Â |
Fibers of annulus fibrosus | 450 | 0.3 | [24] | Â | Â | Â | Â |
Interpubic disc | 5 | 0.45 | [24] | Â | Â | Â | Â |