Skip to main content

Table 3 Analysis of time spent, in minute, on skin closure

From: Evaluation of three methods of suture for skin closure in total knee arthroplasty: a randomized trial

Group

Min.

Max.

Mean

±SD

95 %CI

Group x Group

p1

Simple®

7.03

16.00

7.40

1.88

[6.61–8.19]

Simple x Stratafix®

0.01

Monocryl®

7.00

12.30

8.90

1.44

[8.23–9.57]

Monocryl® x Simple

0.01

Stratafix®

5.00

11.35

9.00

1.77

[8.15–9.87]

Stratafix® x Monocryl®

0.98

  1. Min. minimum; Max. maximum; SD Standard deviation; CI Confidence interval
  2. 1Tukey Test