Skip to main content

Table 2 When the safety factor is greater than or equal to 1, the unit structure can withstand the maximum lateral pressure (accurate to 0.5 N)

From: Design and analysis of three-dimensional printing of a porous titanium scaffold

Lateral pressure (Unit: N)

400 μm

600 μm

800 μm

Imitation diamond-60°

3.0

2.0

1.5

Imitation diamond-90°

5.0

4.0

4.0

Imitation diamond-120°

8.5

7.5

6.0

Regular tetrahedron

65.0

45.0

39.5

Regular hexahedron

185.0

165.0

155.0