Skip to main content

Table 2 Comparison of radiographic data between EF group and VLP group

From: Surgical outcomes of elderly patients aged more than 80 years with distal radius fracture: comparison of external fixation and locking plate

 

External fixation

(n = 41)

Volar locking plate

(n = 28)

p value

Preoperative

 Radial height (mm)

5.4 ± 4.6

6.9 ± 3.9

0.19

 Ulnar variance (mm)

5.1 ± 3.4

4.8 ± 4.1

0.59

 Radial inclination (°)

12.8 ± 7.2

15.0 ± 7.5

0.23

 Palmar tilt (°)

−10.6 ± 18.4

−12.6 ± 16.3

0.41

 Associated ulnar styloid fracture

23

11

0.22

Postoperative day 1

 Radial height (mm)

10.1 ± 2.9

11.2 ± 2.9

0.21

 Ulnar variance (mm)

1.2 ± 2.4

1.4 ± 2.3

0.68

 Radial inclination (°)

21.7 ± 32.4

22.8 ± 5.0

0.63

 Palmar tilt (°)

0.4 ± 8.5

2.8 ± 8.5

0.25

Final follow-up

 Radial height (mm)

8.8 ± 3.2

11.2 ± 5.4

0.06

 Ulnar variance (mm)

3.5 ± 2.8

1.8 ± 3.2

0.01

 Radial inclination (°)

19.1 ± 5.9

22.1 ± 5.2

0.03

 Palmar tilt (°)

1.7 ± 9.9

−0.32 ± 8.0

0.37

  1. Significant p values are shown in bold