Table 5 Histology and enthesis scores for gluteus minimus insertion

From: The pathological features of hip abductor tendon tears – a cadaveric study

  Tendon (SD) p-value (post hoc) Enthesis (SD) p-value (post hoc)
Complete Tear 13.4 (1.7) 0.012 10.5 (1.7) 0.025
Partial Tear 11.1 (2.4) 0.2 9.6 (1.1) 0.16
No Tear 3.0 (1.8) reference 3.3 (1.5) reference
p-value (ANOVA) 0.0095   0.021  
\