From: Traditional and cortical trajectory screws of static and dynamic lumbar fixation- a finite element study

Fig. 8

The earlier contact of the L3-l4 facet joints was used to account for the negative adjacent segment compensation of the static TT and CBT in rotation. a, b, and c show the facet contact for the intact, TT, and CBT models, respectively. d and e show the increased facet forces and disc ROMs of the L3-L4 segment in terms of time step no. that indicates the execution sequence of the finite-element analysis