| Floor effect a | Ceiling effect a | ICC (CI range) | SEM | MDC (I) b | MDC (G) c | ES | SRM |
---|
Overall scale | 0% | 1.52% | 0.936 (0.909–0.955) | 1.346 | 3.73 | 0.32 | −1.123 | −1.554 |
Factor 1 | 0% | 2.27% | 0.907 (0.869–0.935) | 0.886 | 2.46 | 0.21 | − 0.531 | − 0.683 |
Factor 2 | 0% | 1.52% | 0.881 (0.833–0.916) | 0.668 | 1.85 | 0.16 | −1.221 | −1.347 |
Factor 3 | 0% | 2.27% | 0.876 (0.827–0.912) | 0.466 | 1.29 | 0.11 | −1.472 | −1.100 |
- a Percentage of patients with the worst (floor effect) and the best (ceiling effect) score
- b The MDC value at an individual level;
- c The MDC value at the group level
- SC-IdFAI Simplified Chinese version of the Identification of Functional Ankle Instability questionnaire; ICC Intraclass correlation coefficient; CI Confidence interval; SEM Standard error of measurement; MDC Minimal detectable change; ES Effect size; SRM Standardized response mean