Table 6 Comparison of the radiological parameters compared to other studies on the Eclipse prosthesis

From: Do the radiological changes seen at mid term follow up of stemless shoulder prosthesis affect outcome?

Study n Radiolucent lines Secondar
y Glenoid
wear
Glenoid
RL < 1 mm
Bone density loss
ap
-a
ap-b ap-c ax-a ax-b ax-c ap
-a
ap-
b
ap-
c
ax-
a
ax-
b
ax-
c
Habermeyer (2015) 78 27% 7.9% 7.9% 22.2% 1.6% 1.6% 71.9%* 8.3%a
53.3%b
41.3%
Uschok (2017) 14 2 4 1 0 1 0 0
Gallacher (2018) 100 14 1 7 11 1 21
Hawi (2017) 43 2.3% 1 27.3% 29.4%
Current Study 23 3 2 3 2 2 4 8 0 10 2 1 4 3 5
  1. aUncemented Metal back component
  2. bAll polythene glenoid
  3. HA group
  4. n = number of shoulders
  5. ap-a,b,c represent zones in the anterioposterior radiographs
  6. ax-a,b,c represent zones in axillary radiographs