Skip to main content

Table 1 Comparison of the stiffness and load with 2 mm deformation in the experiment and FE calculations

From: Roles of the screw types, proximity and anterior band wiring in the surgical fixation of transverse patellar fractures: a finite element investigation

Without anterior wire

 

Dargel

Present FE model with 10-mm screw placement

Present FE model with 5-mm screw placement

Loading direction parallel

 Linear stiffness (N/mm)

240.67 ± 28.44

275

879

 Load with 2 mm deformation (N)

549.64 ± 56.18

549

1795a

Loading direction 45°

 Linear stiffness (N/mm)

147 ± 50.96

129

372

 Load with 2 mm deformation (N)

351.35 ± 119.88

280

744a

With anterior wire

 

Bryant

Present FE model with 10-mm screw placement

Present FE model with 5-mm screw placement

Loading direction 45°

 Linear stiffness (N/mm)

248.2 ± 30.9

365.3

406.1

  1. ameans the value obtained from linear extrapolation