TY - STD TI - Wei J. How wearables intersect with the cloud and the internet of things: considerations for the developers of wearables. IEEE Consumer Electronics Magazine. 2014:53–6. ID - ref1 ER - TY - STD TI - CSS Insight. Market forecast wearables. 2016. Available from: https://www.ccsinsight.com/our-services/1711. Accessed May 2017. UR - https://www.ccsinsight.com/our-services/1711 ID - ref2 ER - TY - JOUR AU - Giansanti, D. AU - Dozza, M. AU - Chiari, L. AU - Maccioni, G. AU - Cappello, A. PY - 2009 DA - 2009// TI - Energetic assessment of trunk postural modifications induced by a wearable audio-biofeedback system JO - Med Eng Phys VL - 31 UR - https://doi.org/10.1016/j.medengphy.2008.04.004 DO - 10.1016/j.medengphy.2008.04.004 ID - Giansanti2009 ER - TY - JOUR AU - Piwek, L. AU - Ellis, D. AU - Andrews, S. AU - Joinson, A. PY - 2016 DA - 2016// TI - The rise of consumer health wearables: promises and barriers JO - PLoS Med VL - 13 UR - https://doi.org/10.1371/journal.pmed.1001953 DO - 10.1371/journal.pmed.1001953 ID - Piwek2016 ER - TY - BOOK AU - Cajamarca, G. AU - Rodriguez, I. AU - Herskovic, V. AU - Campos, M. PY - 2017 DA - 2017// TI - Ubiquitous Computing and Ambient Intelligence PB - Springer International Publishing CY - Santiago ID - Cajamarca2017 ER - TY - JOUR AU - Hansraj, K. PY - 2014 DA - 2014// TI - Assessment of stresses in the cervical spine caused by posture and position of the head JO - Surg Technol Int VL - 25 ID - Hansraj2014 ER - TY - STD TI - Petropoulos A, Sikeridis D, Antonakopoulos T. SPoMo: IMU-based real-time sitting posture monitoring. Patras; 2017. ID - ref7 ER - TY - JOUR AU - Shekelle, P. AU - Coulter, I. AU - Hurwitz, E. AU - Genovese, B. AU - Adams, A. AU - Mior, S. PY - 1998 DA - 1998// TI - Congruence between decisions to initiate chiropractic spinal manipulation for low Back pain and appropriateness criteria in North America JO - Ann Intern Med VL - 129 UR - https://doi.org/10.7326/0003-4819-129-1-199807010-00003 DO - 10.7326/0003-4819-129-1-199807010-00003 ID - Shekelle1998 ER - TY - JOUR AU - Wang, Q. AU - Markopoulos, P. AU - Yu, B. AU - Chen, W. AU - Timmermans, A. PY - 2017 DA - 2017// TI - Interactive wearable systems for upper body rehabilitation: a systematic review JO - J Neuroeng Rehabil VL - 14 ID - Wang2017 ER - TY - JOUR AU - McCullagh, R. AU - Brady, N. M. AU - Dillion, C. AU - Horgan, N. F. AU - Timmons, S. PY - 2016 DA - 2016// TI - A review of the accuracy and utility of motion sensors to measure physical activity of frail, older hospitalized patients JO - J Aging Phys Act VL - 24 UR - https://doi.org/10.1123/japa.2014-0190 DO - 10.1123/japa.2014-0190 ID - McCullagh2016 ER - TY - JOUR AU - Moher, D. AU - Liberati, A. AU - Tetzlaff, J. AU - Altman, D. AU - Altman, D. AU - Antes, G. PY - 2009 DA - 2009// TI - Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement JO - PLoS Med VL - 6 UR - https://doi.org/10.1371/journal.pmed.1000097 DO - 10.1371/journal.pmed.1000097 ID - Moher2009 ER - TY - JOUR AU - Tanaka, S. AU - Yamakoshi, K. AU - Rolfe, P. PY - 1994 DA - 1994// TI - New portable instrument for long-term ambulatory monitoring of posture change using miniature electro-magnetic inclinometers JO - Med Biol Eng Comput VL - 32 UR - https://doi.org/10.1007/BF02512539 DO - 10.1007/BF02512539 ID - Tanaka1994 ER - TY - JOUR AU - Felisberto, F. AU - Fdez-Riverola, D. AU - Pereira, A. PY - 2014 DA - 2014// TI - A Ubiquitous and low-cost solution for movement monitoring and accident detection based on sensor fusion JO - Sensors (Basel). VL - 14 UR - https://doi.org/10.3390/s140508961 DO - 10.3390/s140508961 ID - Felisberto2014 ER - TY - STD TI - Abyarjoo F, O-Larnnithipong N, Tangnimitchok S, Ortega F, Barreto A. PostureMonitor: real-time IMU wearable technology to Foster poise and health. Miami; 2015. ID - ref14 ER - TY - JOUR AU - Plamondon, A. AU - Delisle, A. AU - Larue, C. AU - Brouillette, D. AU - Mcfadden, D. AU - Desjardins, P. PY - 2007 DA - 2007// TI - Evaluation of a hybrid system for three-dimensional measurement of trunk posture in motion JO - Appl Ergon VL - 38 UR - https://doi.org/10.1016/j.apergo.2006.12.006 DO - 10.1016/j.apergo.2006.12.006 ID - Plamondon2007 ER - TY - STD TI - Harms H, Amft O, Troster G, Appert M, Muller R, Meyer-Heim A. Wearable therapist: sensing garments for supporting children improve posture. Zurich; 2009. ID - ref16 ER - TY - JOUR AU - O’Sullivan, K. AU - Verschueren, S. AU - Pans, S. AU - Smets, D. AU - Dekelver, K. AU - Dankaerts, W. PY - 2012 DA - 2012// TI - Validation of a novel spinal posture monitor : comparison with digital videofluoroscopy JO - Eur Spine J VL - 21 UR - https://doi.org/10.1007/s00586-012-2440-7 DO - 10.1007/s00586-012-2440-7 ID - O’Sullivan2012 ER - TY - JOUR AU - Bhattacharya, A. AU - Warren, J. AU - Teuschler, J. AU - Dimov, M. AU - Medvedovic, M. AU - Lemasters, G. PY - 1999 DA - 1999// TI - Development and evaluation of a microprocessor-based ergonomic dosimeter for evaluating carpentry tasks 1 JO - Appl Ergon VL - 30 UR - https://doi.org/10.1016/S0003-6870(99)00006-X DO - 10.1016/S0003-6870(99)00006-X ID - Bhattacharya1999 ER - TY - STD TI - Sardini E, Serpelloni M, Pasqui V. Daylong sitting posture measurement with a new wearable system for at home body movement monitoring. Brescia; 2015. ID - ref19 ER - TY - STD TI - Tsuchiya Y, Kusaka T, Tanaka T, Matsuo Y, Oda M, Sasaki T, et al. Calibration method for lumbosacral dimensions in wearable sensor system of lumbar alignment. Sapporo; 2015. ID - ref20 ER - TY - JOUR AU - Bell, J. AU - Stigant, M. PY - 2007 DA - 2007// TI - Development of a fibre optic goniometer system to measure lumbar and hip movement to detect activities and their lumbar postures JO - J Med Eng Technol VL - 31 UR - https://doi.org/10.1080/03091900600996735 DO - 10.1080/03091900600996735 ID - Bell2007 ER - TY - JOUR AU - Millington, B. PY - 2016 DA - 2016// TI - “Quantify the invisible”: notes toward a future of posture JO - Crit Public Health VL - 26 UR - https://doi.org/10.1080/09581596.2015.1085960 DO - 10.1080/09581596.2015.1085960 ID - Millington2016 ER - TY - STD TI - Leung K, Reilly D, Hartman K, Stein S, Westecott E. Limber: DIY wearables for reducing risk of office injury. Toronto; 2012. ID - ref23 ER - TY - JOUR AU - Yan, X. AU - Li, H. AU - Li, A. AU - Zhang, H. PY - 2017 DA - 2017// TI - Automation in construction wearable IMU-based real-time motion warning system for construction workers’ musculoskeletal disorders prevention JO - Autom Constr VL - 74 UR - https://doi.org/10.1016/j.autcon.2016.11.007 DO - 10.1016/j.autcon.2016.11.007 ID - Yan2017 ER - TY - CHAP AU - Rednic, R. AU - Gaura, E. AU - Kemp, J. AU - Brusey, J. PY - 2013 DA - 2013// TI - Fielded autonomous posture classification systems: design and realistic evaluation BT - 14th ACIS international conference on software engineering, Artificatial intelligence, Netweorking and parallel/distributed Computing ID - Rednic2013 ER - TY - STD TI - Wang Q, Timmermans A, Toeters M, Markopoulos P, Chen W. Zishi: a smart garment for posture monitoring. The Netherlands; 2016. ID - ref26 ER - TY - JOUR AU - Kairy, D. AU - Lehoux, P. AU - Vincent, C. AU - Visintin, M. PY - 2009 DA - 2009// TI - A systematic review of clinical outcomes, clinical process, healthcare utilization and costs associated with telerehabilitation JO - Disabil Rehabil VL - 31 UR - https://doi.org/10.1080/09638280802062553 DO - 10.1080/09638280802062553 ID - Kairy2009 ER - TY - JOUR AU - Bazzarelli, M. AU - Durdle, N. G. AU - Lou, E. AU - Raso, V. PY - 2003 DA - 2003// TI - A wearable computer for physiotherapeutic scoliosis treatment JO - IEEE Trans Intr Measur VL - 52 UR - https://doi.org/10.1109/TIM.2003.809485 DO - 10.1109/TIM.2003.809485 ID - Bazzarelli2003 ER - TY - JOUR AU - Lou, E. AU - Lam, G. AU - Hill, D. AU - Wong, M. PY - 2012 DA - 2012// TI - Development of a smart garment to reduce kyphosis during daily living JO - Med Biol Eng Comput VL - 50 UR - https://doi.org/10.1007/s11517-011-0847-7 DO - 10.1007/s11517-011-0847-7 ID - Lou2012 ER - TY - CHAP AU - Wu, W. AU - Lin, W. AU - Lee, M. PY - 2014 DA - 2014// TI - Forward-flexed posture detection for the early Parkinson’s disease symptom BT - IEEE International Conference on Systems, Man and Cybernetics ID - Wu2014 ER - TY - JOUR AU - Rao, P. AU - Phan, K. AU - Maharaj, M. AU - Pelletier, M. AU - Walsh, W. AU - Mobbs, R. PY - 2016 DA - 2016// TI - Accelerometers for objective evaluation of physical activity following spine surgery JO - J Clin Neurosci VL - 26 UR - https://doi.org/10.1016/j.jocn.2015.05.064 DO - 10.1016/j.jocn.2015.05.064 ID - Rao2016 ER - TY - STD TI - Mobbs R. Wearables in spine surgery: Beginnings, research and real-world applications. Spinal News Int. 2017; Available from: https://spinalnewsinternational.com/wearables. UR - https://spinalnewsinternational.com/wearables ID - ref32 ER - TY - JOUR AU - Wong, W. AU - Wong, M. PY - 2008 DA - 2008// TI - Trunk posture monitoring with inertial sensors JO - Eur Spine J VL - 17 UR - https://doi.org/10.1007/s00586-008-0586-0 DO - 10.1007/s00586-008-0586-0 ID - Wong2008 ER - TY - JOUR AU - Fathi, A. AU - Curran, K. PY - 2017 DA - 2017// TI - Detection of spine curvature using wireless sensors JO - J King Saud Univ Sci VL - 29 UR - https://doi.org/10.1016/j.jksus.2017.09.014 DO - 10.1016/j.jksus.2017.09.014 ID - Fathi2017 ER - TY - JOUR AU - Kang, S. AU - Choi, H. AU - Park, H. AU - Choi, B. AU - Im, H. AU - Shin, D. PY - 2017 DA - 2017// TI - The development of an IMU integrated clothes for postural monitoring using conductive yarn and interconnecting technology JO - Sensors (Basel). VL - 17 ID - Kang2017 ER - TY - JOUR AU - Nath, N. AU - Akhavian, R. AU - Behzadan, A. PY - 2017 DA - 2017// TI - Ergonomic analysis of construction worker’s body postures using wearable mobile sensors JO - Appl Ergon VL - 62 UR - https://doi.org/10.1016/j.apergo.2017.02.007 DO - 10.1016/j.apergo.2017.02.007 ID - Nath2017 ER - TY - JOUR AU - Faber, G. AU - Kingma, I. AU - Bruijn, S. AU - Dieen, J. PY - 2009 DA - 2009// TI - Optimal inertial sensor location for ambulatory measurement of trunk inclination JO - J Biomech VL - 42 UR - https://doi.org/10.1016/j.jbiomech.2009.06.024 DO - 10.1016/j.jbiomech.2009.06.024 ID - Faber2009 ER - TY - JOUR AU - Gleadhill, S. AU - Bruce, J. AU - James, D. PY - 2016 DA - 2016// TI - The development and validation of using inertial sensors to monitor postural change in resistance exercise JO - J Biomech VL - 49 UR - https://doi.org/10.1016/j.jbiomech.2016.03.012 DO - 10.1016/j.jbiomech.2016.03.012 ID - Gleadhill2016 ER - TY - STD TI - Valdivia S, Blanco R, Penuela L, Rojas D, Kapralos B. A spinal column Exergame for occupational health purposes. Bogota; 2017. ID - ref39 ER - TY - JOUR AU - Xu, J. AU - Bao, T. AU - Lee, U. AU - Kinnaird, C. AU - Carender, W. AU - Huang, Y. PY - 2017 DA - 2017// TI - Configurable, wearable sensing and vibrotactile feedback system for real-time postural balance and gait training: proof-of- concept JO - J Neuroeng Rehabil VL - 14 ID - Xu2017 ER - TY - JOUR AU - Dunne, L. AU - Walsh, P. AU - Hermann, S. AU - Smyth, B. AU - Caulfield, B. PY - 2008 DA - 2008// TI - Wearable monitoring of seated spinal posture JO - IEEE Trans Biomed Circuits Syst VL - 2 UR - https://doi.org/10.1109/TBCAS.2008.927246 DO - 10.1109/TBCAS.2008.927246 ID - Dunne2008 ER - TY - CHAP AU - Motoi, K. AU - Ikeda, K. AU - Kuwae, Y. AU - Yuji, T. AU - Higashi, Y. AU - Nogawa, M. PY - 2006 DA - 2006// TI - Development of an ambulatory device for monitoring posture change and walking speed for use in rehabilitation BT - IEEE EMBS Annual International Conference ID - Motoi2006 ER - TY - STD TI - Gopalai A, Senanayake S, Lim K. Intelligent Vibrotactile biofeedback system for real-time postural correction on perturbed surfaces. Sarawak Campus; 2012. ID - ref43 ER - TY - STD TI - Miyajima S, Tanaka T, Imamura Y, Kusaka T. Lumbar joint torque estimation based on simplified motion Measurement using multiple inertial sensors. Sapporo; 2015. ID - ref44 ER - TY - STD TI - Ribeiro D, Milosavljevic S, Abbott J. Effectiveness of a lumbopelvic monitor and feedback device to change postural behaviour: a protocol for the ELF cluster randomised controlled trial. BMJ Open. 2017;7(1):–10. ID - ref45 ER - TY - STD TI - Hermanis A, Cacurs R, Nesenbergs K, Greitans M, Syundyukov E, Demonstration Abstract SL. Wearable sensor grid architecture for body posture and surface detection and rehabilitation. Riga; 2015. ID - ref46 ER - TY - JOUR AU - Lin, W. AU - Chou, W. AU - Tsai, T. AU - Lin, C. AU - Lee, M. PY - 2016 DA - 2016// TI - Development of a wearable instrumented vest for posture monitoring and system usability verification based on the technology acceptance model JO - Sensors (Basel) VL - 16 ID - Lin2016 ER - TY - JOUR AU - Voinea, G. AU - Butnariu, S. AU - Measurement, M. G. PY - 2017 DA - 2017// TI - Geometric modelling of human spine posture for medical rehabilitation purposes using a wearable monitoring system based on inertial sensors JO - Sensors (Basel). VL - 17 ID - Voinea2017 ER - TY - CHAP AU - Charry, E. AU - Umer, M. AU - Taylor, S. PY - 2011 DA - 2011// TI - Design and validation of an ambulatory inertial system for 3-D measurements of low back movements BT - Proceedings of the 2011 7th international conference on intelligent sensors, sensor networks and information processing UR - https://doi.org/10.1109/ISSNIP.2011.6146618 DO - 10.1109/ISSNIP.2011.6146618 ID - Charry2011 ER -