Skip to main content

Table 3 Comparison of reported hardware removal rates for midshaft clavicular fractures treated with noncontoured or precontoured plates

From: The first 100 patients treated with a new anatomical pre-contoured locking plate for clavicular midshaft fractures

Study

Year

Type of plate

Removal rate (%)

Kabak [22]

2004

Noncontoured

39

Chen [7]

2008

Noncontoured

74

Chandrasenan [20]

2008

Precontoured

0

Noncontoured

60

VanBeek [12]

2011

Precontoured

11

Noncontoured

21

Lai [23]

2012

Noncontoured

37

Campochiaro [24]

2012

Precontoured

15

Gilde [25]

2014

Noncontoured

9

Ranalletta [11]

2015

Precontoured

13

Rongguang [18]

2016

Noncontoured

66

Precontoured

45

Our study

2018

Precontoured

31