Skip to main content

Table 4 Feasibility real time rating vs. video rating (n = 20)

From: Intra and interrater reliability and clinical feasibility of a simple measure of cervical movement sense in patients with neck pain

Comparison

Outcome variable

Pattern

Velocity

ICC agreement (95% CI)

95% CI

SEM

Rater 1 vs. real time

Time

F8

Accurate

1

1–1

<  0.01

Accurate & Fast

1

1–1

<  0.01

ZZ

Accurate

1

1–1

<  0.01

Accurate & Fast

0.99

0.98–1

0.04

Error Frequency

F8

Accurate

0.73

0.58–0.82

2.90

Accurate &Fast

0.75

0.61–0.83

1.41

ZZ

Accurate

0.84

0.72–0.90

1.02

Accurate &Fast

0.56

0.36–0.70

1.71

Rater 2 vs. real-time

Time

F8

Accurate

1

0.99–1

0.05

Accurate &Fast

1

1–1

0.02

ZZ

Accurate

1

1–1

<  0.01

Accurate &Fast

1

0.99–1

0.02

Error frequency

F8

Accurate

0.67

0.50–0.78

2.98

Accurate &Fast

0.67

0.53–0.78

1.70

ZZ

Accurate

0.74

0.60–0.82

1.60

Accurate &Fast

0.54

0.39–0.69

1.42

  1. ICC Intraclass Correlation Coefficients for agreement, 95% CI 95% Confidence interval, SEM Standard error of measurement, F8 figure of 8, ZZ zigzag