Skip to main content

Table 3 Interrater reliability (n = 20)

From: Intra and interrater reliability and clinical feasibility of a simple measure of cervical movement sense in patients with neck pain

Variable

Pattern

Velocity

ICC of agreement

95% Confidence interval

SEM

Time

F8

Accurate

1

1–1

0.05

Accurate& fast

1

0.99–1

0.02

ZZ

Accurate

1

1–1

<  0.01

Accurate& fast

1

0.98–1

0.03

Error frequency

F8

Accurate

0.76

0.63–0.86

1.74

Accurate& fast

0.91

0.86–0.94

0.47

ZZ

Accurate

0.80

0.60–0.88

0.78

Accurate& fast

0.84

0.70–0.92

0.48

Error magnitude

F8

Accurate

0.78

0.62–0.86

2.02

Accurate& fast

0.87

0.77–0.92

1.05

ZZ

Accurate

0.88

0.68–0.93

0.82

Accurate& fast

0.94

0.85–0.97

0.69

  1. ICC Intraclass Correlation Coefficients for agreement, SEM Standard error of measurement, F8 figure of 8, ZZ zigzag