Skip to main content
  • Research article
  • Open access
  • Published:

Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration

Abstract

Background

Fatty Degeneration (FD) of the rotator cuff muscles influences functional and anatomical outcome after rotator cuff repair. The MRI based estimation of fatty degeneration is the gold standard. There is some evidence that Ultrasound elastography (EUS) can detect local differences of tissue stiffness in muscles and tendons. Shear-wave elastography (SWE) was evaluated to determine the extent to which shear wave velocity was associated with measures of fatty degeneration. MRI-spectroscopic fat measurement was used as a reference to quantify the amount of fat in the muscle belly.

Methods

Forty-two patients underwent SWE of the supraspinatus muscles at its thickest diameter. After ultrasound evaluation an MRI-spectroscopic fat measurement of the supraspinatus muscle was performed using the SPLASH-technique. A gel filled capsule was used to locate the measured area in the MRI. The values of shear wave velocity (SWV) measured with SWE and spectroscopic fat measurement were correlated statistically using Pearson’s correlation test.

Results

Correlation of the fat amount measured with MRI-spectroscopy and the SWV measured with SWE was ρ =0.82. Spectroscopic measured fat ratio of the supraspinatus muscle ranged from 0% to 77.41% and SWV from 1.59 m/s to 5.32 m/s. In 4 patients no sufficient SWE could be performed, these individuals showed a larger diameter of the overlying soft tissue. SWV measured with SWE showed a good correlation with MRI spectroscopic fat amount of the supraspinatus muscle.

Conclusion

These preliminary data suggest that SWE may be a sufficient tool in detecting and estimating the amount of fatty degeneration in the supraspinatus muscle in real time. Large overlying soft tissue may be a limitation in performing sufficient EUS.

Ethical Committee Approval: Nr: 156/14 Date 12th August 2014.

Level of Evidence: III.

Peer Review reports

Background

Fatty degeneration (FD) of the rotator cuff occurs after tendon rupture or nerve damage and affects the functional and anatomical outcome after rotator cuff repair [10, 31]. Preoperative detection and classification of FD is an essential part of planning operative rotator cuff repair. In case of advanced FD a rotator cuff repair has high rates of failure and leads to inferior clinical results [20]. FD is a non-reversible process even after successful rotator cuff repair [2, 12, 25]. In the clinical setting the MRI based modified Goutallier classification for t1-weighted oblique sagittal images is comonly used [9]. Conventional ultrasound has lately become a standard diagnostic tool for detecting rotator cuff tears due to its high sensitivity [11, 14, 21]. Conventional ultrasound techniques only allow a semi-quantitative grading of FD and is still considered an experimental modality [30].

Ultrasound elastography (EUS) is most often clinically used to evaluate hepatic, thyroid and breast pathologies [5, 8, 27]. Several studies described the usability of EUS for detecting changes in the musculoskeletal system, but there remains a lack of standardization using this technique for detecting musculoskeletal pathologies in the clinical setting. The use of EUS for musculoskeletal application has been reviewed extensively elsewhere [1, 3, 18].

EUS includes different techniques (Fig. 1): Strain or compression elastography (SE) evaluates the elasticity of the underlying tissue by measuring the degree of deformation. Compression is applied manually or through physiological movements (breathing, vessel pulsation). This enables a semi-quantitative measurement of the tissue elasticity, as the elasticity is estimated by comparing the strain in the target tissue with strain of the surrounding tissue. Due to the manual applied pressure this technique has been shown to be operator depending [1, 3].

Fig. 1
figure 1

Experimental setting. The ultrasound probe was placed in an oblique sagittal position (a). The largest diameter of the supraspinatus muscles was detected using b-mode ultrasound (b). SWE measurement was performed at this location in a parallel orientation of the transducer to the muscle fibers (c). The velocity of shear wave propagation was measured at 10–15 points in the ROI. The measurement was repeated 5 times to cover almost the whole cross section area of the muscle. To ensure spectroscopic measurement at the same location the point of measurement was marked with a MRI visible gel capsule fixed to the patient’s skin

Shear wave elastography (SWE) was introduced by Sarvazyan et al. in 1998. A radiation force of a focused ultrasonic push pulse (duration approximately 320 μs) is used to induce a tissue oscillation of up to 20 μm. These so-called shear-waves move transversally to the direction of the ultrasonic waves. The shear wave velocity (SWV) depends on the elasticity of the examined tissue [26]. Using tracking beams of the transducer (acoustic radiation force impulse, ARFI) the propagation velocity of the shear-waves can be measured. This method is propagated as an objective and reproducible quantification of the tissue elasticity which is in contrast to SE not depending from the manual compression by the observer (Fig. 2) [26]. However, as it is an ultrasound technique with manual application of the transducer it may be susceptible for observer dependent bias.

Fig. 2
figure 2

SWE for detecting FD in the supraspinatus muscle. The left column shows the color-coded shear wave velocity in the supraspinatus muscle. The right column shows the related T1 weighted oblique sagittal MRI images. Areas of higher fat amount appear blue to green in the shear wave EUS. Spectroscopic fat quantification with the SPLASH technique revealed a quantitative fat amount of (a) 77.41%, (b) 4.93%

Experimental studies showed that SWE is capable of measuring muscle stiffness in the supraspinatus muscle and may detect regions of different elasticity in the muscle, without focusing on FD. These preliminary studies showed that the orientation of the ultrasound probe needs to be parallel to the muscle fibers to achieve reliable results for the tissue stiffness with SWE [4, 15].

The aim of this study was to evaluate how and if shear wave propagation trough the tissue of the supraspinatus muscle correlates with its amount of fatty degeneration. The semi-quantitative measurement using the Goutallier technique has been reported to have interobserver reliabilities between 0.43–0.86 [9, 24, 29]. In this study an experimental MRI-spectroscopic technique for fat measurement was used as reference. As this has been shown to allow an exact quantification of the FD in the supraspinatus muscle, by analyzing the ratio of the T1 related signal intensity of muscle and fat in a manually placed region of interest in a 2D MRI slice [16, 17]. In order to put these experimental methods in a clinical context, the results were correlated with the widely used MRI-based Goutallier scale. The hypothesis was that SWV correlates with the amount of fatty infiltration of the suprapinatus muscle tissue measured with a quantitative MRI spectroscopic method.

Methods

Level of evidence: III, analytic study

Institutional review board approval was acquired prior to the inception of this study, and informed consent was obtained from each patient.

Forty-two patients with history of rotator cuff tear were included in this study. Mean age of the patients was 58.8 ± 7,65 years (range from 40 to 76). Thirteen were female and 29 were male patients. Twenty-eight underwent rotator cuff repair, the time after surgery was 2.3 years (± 0.7). The other patients had a history of rotator cuff tear but were treated conservatively. Patients’ clinical features are shown in Table 1. The maximum diameter of the supraspinatus muscle was detected using conventional ultrasound (b-mode) and this area was marked using a gel capsule (Fig. 3). After detection of this area a shear wave ultra-sound measurement (SWE) of the supraspinatus muscle was performed with a Siemens Acuson S3000 ultrasound system (Siemens AG, Munich, Germany) using a linear transducer (10mHz) the SWV was assessed with the software of the ultrasound device (virtual touch tissue imaging quantification [VTIQ], Siemens Medical Solutions, Siemens AG, Munich, Germany). Tissue elasticity was measured by aligning the transducer parallel to the muscle fibers at the largest diameter of the supraspinatus muscle (Fig. 1). As the process of manually selecting data via the ultrasound system’s console has the potential to significantly introduce bias SWE was performed by one blinded radiologist (DK). The shear wave velocity (m/s) was measured at 10–15 points in the manually placed region of interest in 5 pictures trying to fully cover the muscles cross section. The forearm of the patients was placed on an armrest to avoid muscle contraction during the examination .

Table 1 Patients’ clinical features
Fig. 3
figure 3

Scatter Plot of shear wave velocity [m/s] and amount of fat measured with MR-spectroscopy using the SPLASH technique [%]

On the same day a standard MRI scan of the shoulder was obtained. The MR-spectroscopy (SPLASH-technique (spectroscopic fast low angle shot)) and the postprocessing for quantification of the fat/water ratio was performed using a previously described technique by our workgroup [11, 17] (Fig. 4) Measuring the same area as in the ultrasound elastography was ensured with a gel capsule fixed to the patient’s skin.

Fig. 4
figure 4

Spectroscopic analyses and quantification of the fat/water ration in the supraspinatus muscle (left column). The middle column shows the manual delineated borders of the M. supraspinatus in which the spectroscopic analyses were performed. The right collum shows the accordingly oblique-sagittal T1 weighted MRI images. Calculated values for these examples of the fat/water ratio were (a) 1.29%, (b) 12.67% and (c) 77.41%

All MRIs were rated according the MRI-based Goutallier Classification (oblique-sagittal t1-weighted images) by 5 raters. According to the scaling by Fuchs et al. Grade 0 was defined as no fatty infiltration, grade 1 as some fatty streaking of the supraspinatus, grade 2 as less fat than muscle, grade 3 as equal amounts of fat and muscle, and grade 4 as more fat than muscle [9]. All raters were orthopedic surgeons with clinical focus in shoulder surgery.

The thickness of the overlying tissue was directly measured in oblique-sagittal t1-weighted images using the clinical PACS System.

The correlation between the methods was calculated using Pearson’s rank correlation test (ρ). Degrees of reliability were set to the scale determined by Landis and Koch [19]. A statistical power analysis was performed using G*Power 3.1 [7]. Power analysis revealed a minimum number of Patients of n = 32 to obtain a power of 80% for finding a significant difference between a Pearson’s ρ of 0.65 an 0.85 (β > 0.8).

Median of the measured SWV of each muscle was statistically correlated with its spectroscopically measured fat amount using Pearson’s correlation test. The median of the Goutallier scale evaluated by independent 5 raters (with clinical focus on shoulder surgery) was correlated with the median of shear wave velocity and the spectroscopically measured fat amount using Spearman’s rank correlation test. Statistical analyses were performed using SPSS version 14 (IBM, Armonk NY, USA). Differences were considered as statistically significant, when p < 0.05.

Results

Correlation of SWV measured with SWE in the patients’ supraspinatus muscles with the spectroscopic fat ratio showed a Pearson’s ρ of 0.82. This is a good correlation according to the criteria suggested by Landis and Koch [19]. Spectroscopic MRI analysis revealed fat ratios in 42 shoulders ranging from 0 to 77.41%, with a mean FD of 17.9% ± 18.9%. Medians of SWV ranged from 1.59 m/s to 5.32 m/s, with a mean of 1.81 m/s. SWV increased with higher fat water ratio. In four shoulders it was not possible to perform a sufficient SWE, consequently no SWE data were gained for these supraspinatus muscles. In these patients (n = 4) the mean diameter of overlying soft tissue was 20.04 mm (ranged from 11.47 mm to 31.44 mm). For the other patients (n = 38) the mean diameter of overlying soft tissue was 12.98 mm (ranged from 10.01 mm to 14.14 mm). The differences in the diameter did not reach the level of statistical significance.

Correlating the Goutallier scale with the spectroscopic fat measurement revealed a correlation of Pearson’s ρ =0.40 and with the SWV a correlation of ρ =0.48 (Table 2). Interpreted according to the criteria after Landis and Koch this represents a moderate agreement.

Table 2 Correlation and p-values of the different approaches to quantify FD

Discussion

Fatty degeneration of a muscle cause changes of tissue elasticity [4, 22]. The aim of the current study was to test if shear wave velocity is affected by fatty infiltration of the supraspinatus muscle tissue. We observed an increased SWV when increased amounts of fat were found in the muscles tissue. Correlation of the spectroscopical measured fat amount with the clinical widely used Goutallier scale was only moderate.

Both shear wave elastography and MRI-spectroscopy represent experimental methods to quantify FD in the rotator cuff muscles. As the reliability of the MRI-based Goutallier scale is debatable and only represents a semi-quantitative classification system, objective methods which allow exact quantification are needed. Therefore, the present study compares two quantitative methods for measuring the FD even if spectroscopic fat measurement has no clinical relevance until yet, it is able to provide quantitative data of fat in a muscle. To allow clinical conclusions we compared the two experimental methods with the widely used semi-quantitative Goutallier scale. The relevance for using quantitative methods is highly indicated by the present data showing good correlation between the two quantitative approaches and only moderate correlation of these compared to the semi-quantitative Goutallier classification.

Regarding SWE there are no standard protocols for the application in the musculoskeletal system. Until now the most commonly applied technique in investigating the musculoskeletal system is strain elastography. As this is not a quantitative technique in regard to tissue elasticity, efforts towards establishing semi-quantitative scores have been made. Studies investigating the detection of FD with ultrasound or EUS are rare and the role for detection and the quantification of FD remains experimental. There are two studies comparing strain elastography (SE) to semi-quantitative MRI-analysis finding correlations between 0.744–0.81 [6, 28]. These studies are based on a different technique of elastography and are, due to the technique of SE, semi-quantitative analyses for the estimation of FD, therefore the comparability of these findings with the present study is limited, but the correlations reported seem to be comparable to the findings of this study.

Hatta et al. performed SE in 12 fresh porcine shoulders to investigate the influence of the overlying tissue to the strain ratio. They noticed that the strain ratio is influenced if the overlying tissue is larger than 22 mm [13]. In our study in 4 patients a sufficient SWE could not be achieved. If this was a technical problem or is in context with the large overlying soft tissue in these individuals remains unclear, as the difference of the diameter did not reach level of significance. But large overlying tissue might be a limitation for performing sufficient EUS.

SWE has been used experimentally for quantifying the mechanical properties of muscle tissue without focusing on the amount of FD. Itoigawa et al. measured the elastic module in different areas of human supraspinatus specimen. They found muscle elasticity was different with positioning of the transducer and proposed that SWE is able to quantify passive muscle stiffness [15]. Eby et al. confirmed these findings in a porcine brachialis muscle model and found that shear waves do not propagate well if the probe is not in an exact parallel position with the muscle fibers [4]. This resulted in parallel probe alignment to muscle fibers of the supraspinatus, but as ultrasound is a dynamic examination the correct alignment of the transducer may not be ensured for the whole procedure, which may represent a potential bias in the present investigation.

As only one blinded investigator (DK) performed SWE intra- or interobserver effects were not been evaluated in the present study and makes it susceptible to observer depended bias.

Muscle relaxation was not measured and was obtained by placing the arm on the chair’s armrest. The grade of muscle contraction highly affects the muscles stiffness [13]. This is supported by the findings of Muraki et al. who found significant changes in muscle stiffness with different levels of muscle contraction in a cohort of 23 healthy probands using SE [22].

Further limitations are that the ROI was selected individually in the supraspinatus muscle and there was no control if the whole muscle cross section area was covered, hence regional inhomogeneities may lead to incorrect values of overall shear wave propagation velocity [23]. Without having a biological reference (e.g. histological quantification) of the FD the exact quantification of the amount of FD remains unknown even with spectroscopic measuring techniques.

Conclusion

The techniques used in this study are experimental and only few studies are comparable to the design of the present study. Further research must show the reproducibility of these results. We think estimation of FD in real time using SWE is feasible and may be a cost effective alternative to MRI quantification of FD. Especially when contraindications for the use of MRI are present or patients suffer from claustrophobia, this method may be an attractive alternative. According to our knowledge this is the first study trying to use quantitative methods estimating the amount of FD with ultrasound techniques. We think further basic science studies are necessary to create reference data to implement SWE into the clinical setting.

Abbreviations

EUS:

Ultrasound elastography

FD:

Fatty degeneration

m/s:

meters/s

mHz:

mega Hertz

mm:

millimeter

MRI:

Magnet resonance imaging

PACS:

Picture archiving and communication system

SE:

Strain or compression elastography

SPLASH:

Spectroscopic fast low angle shot

SWE:

Shear-wave elastography

References

  1. Brandenburg JE, Eby SF, Song P, Zhao H, Brault JS, Chen S, et al. Ultrasound Elastography: the new frontier in direct measurement of muscle stiffness. Arch Phys Med Rehabil. 2014;95(11):2207–19. Available from: http://www.sciencedirect.com/science/article/pii/S0003999314005012?via%3Dihub

  2. Burkhart SS, Barth JRH, Richards DP, Zlatkin MB, Larsen M. Arthroscopic repair of massive rotator cuff tears with stage 3 and 4 fatty degeneration. Arthroscopy. 2007;23:347–54. https://doi.org/10.1016/j.arthro.2006.12.012.

    Article  PubMed  Google Scholar 

  3. Drakonaki EE, Allen GM, Wilson DJ. Ultrasound elastography for musculoskeletal applications. Br J Radiol. 2012;85(November):1435–45. https://doi.org/10.1259/bjr/93042867.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  4. Eby SF, Song P, Chen S, Chen Q, Greenleaf JF, An KN. Validation of shear wave elastography in skeletal muscle. J Biomech. 2013;46:2381–7. https://doi.org/10.1016/j.jbiomech.2013.07.033.

    Article  PubMed  Google Scholar 

  5. Evans A, Whelehan P, Thomson K, McLean D, Brauer K, Purdie C, et al. Quantitative shear wave ultrasound elastography: initial experience in solid breast masses. Breast Cancer Res. 2010;12:R104. https://doi.org/10.1186/bcr2787.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Faschingbauer R, Schreiber V, Feuchtner G, Soegner P, Smekal V, Jaschke W KA. Evaluation of findings in Sonoelastography (SEL) in fatty atrophy in rotator cuff compared to magnetic resonance tomography (MRT). In: Euroson 2010; august 22–25; Copenhagen. Copenhagen: Faschingbauer R; 2010.

  7. Faul F, Erdfelder E, Buchner A, Lang A-G. Statistical power analyses using G*power 3.1: tests for correlation and regression analyses. Behav Res Methods. 2009;41(4):1149–60. Available from: https://link.springer.com/article/10.3758%2FBRM.41.4.1149

  8. Ferraioli G, Tinelli C, Zicchetti M, Above E, Poma G, Di Gregorio M, et al. Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity. Eur J Radiol. 2012;81(11):3102–6. Available from: http://dx.doi.org/10.1016/j.ejrad.2012.05.030doi:10.1016/j.ejrad.2012.05.030

    Article  PubMed  Google Scholar 

  9. Fuchs B, Weishaupt D, Zanetti M, Hodler J, Gerber C. Fatty degeneration of the muscles of the rotator cuff: assessment by computed tomography versus magnetic resonance imaging. J Shoulder Elb Surg. Jan [cited 2015 Jan 14];8(6):599–605. Available from: https://www.ncbi.nlm.nih.gov/pubmed/10633896.

  10. Gerber C, Fuchs B, Hodler J. The results of repair of massive tears of the rotator cuff. J Bone Joint Surg Am. 2000;82:505–15.

    Article  CAS  PubMed  Google Scholar 

  11. Gilbert F, Böhm D, Eden L, Schmalzl J, Meffert RH, Köstler H, et al. Comparing the MRI-based Goutallier classification to an experimental quantitative MR spectroscopic fat measurement of the supraspinatus muscle. BMC Musculoskelet. Disord. 2016;1–7. Available from: https://doi.org/10.1186/s12891-016-1216-3doi:10.1186/s12891-016-1216-3

  12. Goutallier D, Postel JM, Lavau L, Bernageau J. [Impact of fatty degeneration of the suparspinatus and infraspinatus msucles on the prognosis of surgical repair of the rotator cuff]. Rev Chir Orthop Reparatrice Appar Mot. 1999 [cited 2015 Jan 14];85(7):668–76. Available from: http://www.em-consulte.com/article/159270/alertePM

  13. Hatta T, Yamamoto N, Sano H, Itoi E. In vivo measurement of rotator cuff; 2014. p. 1641–6. https://doi.org/10.7863/ultra.33.9.1641.

    Google Scholar 

  14. Hedtmann A, Fett H. Ultrasound diagnosis of the rotator cuff. Orthopade. 2002;31:236–46. Available from: http://www.ncbi.nlm.nih.gov/pubmed/12017847

    Article  CAS  PubMed  Google Scholar 

  15. Itoigawa Y, Sperling JW, Steinmann SP, Chen Q, Song P, Chen S, et al. Feasibility assessment of shear wave elastography to rotator cuff muscle. Clin Anat. 2015;28(November 2014):213–8. Available from: http://onlinelibrary.wiley.com/doi/10.1002/ca.22498/abstract

  16. Kenn W, Böhm D, Gohlke F, Hümmer C, Köstler H, Hahn D. 2D SPLASH: a new method to determine the fatty infiltration of the rotator cuff muscles. Eur Radiol. 2004;14:2331–6. https://doi.org/10.1007/s00330-004-2410-5.

    Article  PubMed  Google Scholar 

  17. Köstler H, Kenn W, Hümmer C, Böhm D, Hahn D. [2D-SPLASH spectroscopy to determine the fat/water ratio in the muscle of the rotator cuff]. Rofo. 2002 [cited 2015 Jan 14];174(8):991–5. Available from: https://www.ncbi.nlm.nih.gov/pubmed/?term=10.1055%2Fs-2002-32922

  18. Lalitha P, Balaji Reddy M, Jagannath RK. Musculoskeletal applications of elastography: a pictorial essay of our initial experience. Korean J Radiol. 2011;12(3):365–75. https://doi.org/10.3348/kjr.2011.12.3.365.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Landis JR, Koch GG. Biometrics [Internet]. 1977 Mar [cited 2014 Jul 20];33(1):159–74. Available from: http://www.ncbi.nlm.nih.gov/pubmed/843571

  20. Mellado JM, Calmet J, Olona M, Esteve C, Camins A, Pérez Del Palomar L, et al. Surgically repaired massive rotator cuff tears: MRI of tendon integrity, muscle fatty degeneration, and muscle atrophy correlated with intraoperative and clinical findings. In: American journal of Roentgenology; 2005. p. 1456–63. https://doi.org/10.2214/ajr.184.5.01841456.

    Google Scholar 

  21. Middleton WD, Teefey SA, Yamaguchi K. Sonography of the rotator cuff: analysis of interobserver variability. Am J Roentgenol. 2004;183:1465–8. https://doi.org/10.2214/ajr.183.5.1831465.

    Article  Google Scholar 

  22. Muraki T, Ishikawa H, Morise S, Yamamoto N, Sano H, Itoi E, et al. Ultrasound elastography-based assessment of the elasticity of the supraspinatus muscle and tendon during muscle contraction. J Shoulder Elb Surg. 2014;24(1):120–6. Available from: http://dx.doi.org/10.1016/j.jse.2014.04.012doi:10.1016/j.jse.2014.04.012

    Article  Google Scholar 

  23. Nakagaki K, Ozaki J, Tomita Y, Tamai S. Fatty degeneration in the supraspinatus muscle after rotator cuff tear. J Shoulder Elb Surg. [Internet]. Jan [cited 2015 Jan 18];5(3):194–200. Available from: http://www.ncbi.nlm.nih.gov/pubmed/8816338

  24. Oh JH, Kim SH, Choi J-A, Kim Y, Oh CH. Reliability of the grading system for fatty degeneration of rotator cuff muscles. Clin Orthop Relat Res. 2010 [cited 2015 Jan 14];468(6):1558–64. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2865616/?tool=pmcentrez

  25. Oh JH, Kim SH, Kang JY, Oh CH, Gong HS. Effect of age on functional and structural outcome after rotator cuff repair. Am J Sports Med. 2010;38:672–8. https://doi.org/10.1177/0363546509352460.

    Article  PubMed  Google Scholar 

  26. Sarvazyan A, Rudenko O, Swanson S. Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics [Internet]. Ultrasound Med. …. 1998;Available from: http://linkinghub.elsevier.com/retrieve/pii/S0301562998001100

  27. Sebag F, Vaillant-Lombard J, Berbis J, Griset V, Henry JF, Petit P, et al. Shear wave elastography: a new ultrasound imaging mode for the differential diagnosis of benign and malignant thyroid nodules. J Clin Endocrinol Metab. 2010;95:5281–8. https://doi.org/10.1210/jc.2010-0766.

    Article  CAS  PubMed  Google Scholar 

  28. Seo J-B, Yoo J-S, Ryu J-W. The accuracy of sonoelastography in fatty degeneration of the supraspinatus: a comparison of magnetic resonance imaging and conventional ultrasonography. J Ultrasound. 2014 [cited 2015 Mar 12];17(4):279–85. Available from: https://link.springer.com/article/10.1007%2Fs40477-014-0064-y

  29. Slabaugh MA, Friel NA, Karas V, Romeo AA, Verma NN, Cole BJ. Interobserver and intraobserver reliability of the Goutallier classification using magnetic resonance imaging: proposal of a simplified classification system to increase reliability. Am J Sports Med. 2012 [cited 2014 Dec 31];40(8):1728–34. Available from: https://www.ncbi.nlm.nih.gov/pubmed/?term=10.1177%2F0363546512452714

  30. Wall LB, Teefey SA, Middleton WD, Dahiya N, Steger-May K, Kim HM, et al. Diagnostic performance and reliability of ultrasonography for fatty degeneration of the rotator cuff muscles. J Bone Joint Surg Am. 2012 [cited 2015 Jan 10];94(12):e83. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3368496/?tool=pmcentrez

  31. Yamaguchi H, Suenaga N, Oizumi N, Hosokawa Y, Kanaya F. Will preoperative atrophy and fatty degeneration of the shoulder muscles improve after rotator cuff repair in patients with massive rotator cuff tears? Adv Orthop. 2012;2012(2):195876. Available from: http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=3263590&tool=pmcentrez&rendertype=abstract

    PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgments

None

Funding

This research received no grant from any funding agency in the public, commercial or not-for-profit sectors.

Availability of data and materials

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Author information

Authors and Affiliations

Authors

Contributions

FG: made substantial contribution in design and conception of the study, wrote the manuscript. DK: performed acquisition of data and interpretation of data. AW: performed acquisition of data and interpretation of data (spectroscopy), revisited the manuscript critically. JS: participated in the design of the study and performed the statistical analysis. HK: performed acquisition of data and interpretation of data (spectroscopy), revisited the manuscript critically. BS: made substantial contribution in design an conception of the study. DB: performed acquisition of data and interpretation of data. All authors approved the final version of the manuscript.

Corresponding author

Correspondence to Fabian Gilbert.

Ethics declarations

Ethics approval and consent to participate

We declare that the study has been performed in accordance with the Declaration of Helsinki and has been approved by the ethical Committee of the University of Würzburg (Ethical Committee Approval: Nr: 156/14 Date 12th August 2014).

Written informed consent to participate in the study was obtained from each participant.

Consent for publication

Not applicable

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Gilbert, F., Klein, D., Weng, A.M. et al. Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration. BMC Musculoskelet Disord 18, 549 (2017). https://doi.org/10.1186/s12891-017-1911-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12891-017-1911-8

Keywords