Skip to main content

Table 1 The intra- and inter-rater reliability of post-fracture clavicular length measurement

From: Bone shortening of clavicular fractures: comparison of measurement methods

 

ICC

Mean (mm)

SD crude (mm)

SEM (mm)

MDC (mm)

Silva et al

 Intrarater 1

0.864

12.9

11.8

4.4

12

 Intrarater 2

0.908

25.5

13.3

4

11

 Interrater 1 and 2

0.724

20

13.8

7.4

20

Hill et al

 Intrarater 1

0.871

23.2

11.8

4.2

12

 Intrarater 2

0.878

21.4

12.5

4.4

12

 Interrater 1 and 2

0.768

21.7

11.9

5.7

16

Lazarides et al.

 Intrarater 1

0.942

7.8

11.8

2.8

7.9

 Intrarater 2

0.945

7.7

12.0

2.8

7.8

 Interrater 1 and 2

0.901

7.9

11.2

3.5

9.7

  1. ICC: intra-class correlation. Mean (mm): mean bone shortening in millimeters. SD crude: standard deviation of bone shortening in millimeters. SEM (mm): standard error of measurement in millimeters. MDC(mm): minimal detectable change in millimeters. For inter-rater analysis, the second measurement made by each rater was compared