Skip to main content

Table 2 Comparison of accuracy in acetabular cup placement according to type of surgery

From: Surgical accuracy, function, and quality of life of simultaneous versus staged bilateral Total hip Arthroplasty in patients with Osteonecrosis of the femoral head

Parameter

Simultaneous BTHA (N = 63)

Staged BTHA (N = 60)

P value

Mean inclination (°; mean ± SD; range)

 First-operated hip

42.0 ± 6.2 (29.3 to 55.7)

40.8 ± 7.3 (24.5 to 61.6)

0.333#

 Second-operated hip

40.7 ± 5.4 (22.8 to 52.4)

41.7 ± 7.2 (25.8 to 63.5)

0.401#

Mean anteversion (°; mean ± SD; range)

   

 First-operated hip

16.7 ± 6.9 (2.7 to 30.5)

17.3 ± 7.5 (4.7 to 36.3)

0.639#

 Second-operated hip

17.9 ± 5.2 (7.8 to 30.8)

17.5 ± 7.7 (3.8 to 34.6)

0.706#

Cups within safe zone for inclination (n; %)

 First-operated hip

  Lewinnek (30° to 50°)

56 (89)

51 (85)

0.522

  Callanan (30° to 45°)

42 (67)

45 (75)

0.310

 Second-operated hip

  Lewinnek (30° to 50°)

60 (95)

51 (85)

0.056

  Callanan (30° to 45°)

51 (81)

39 (65)

0.046

Cups within safe zone for anteversion (n; %)

 First-operated hip

  Lewinnek, or Callanan (5° to 25°)

50 (79)

47 (78)

0.889

 Second-operated hip

  Lewinnek, or Callanan (5° to 25°)

60 (95)

46 (77)

0.003

  1. BTHA bilateral total hip arthroplasty, SD standard deviation
  2. #Independent t-test
  3. Chi-square test.