Table 2 Distribution of the subsidences measured by EBRA-FCA and the corresponding details about alignemnt, cementing quality and offset

From: Prospective two-year subsidence analysis of 100 cemented polished straight stems - a short-term clinical and radiological observation

CRI Patient Subsidence EBRA-FCA (mm) Alignement Cementing Quality (Barrack) Standard/Lateralised Offset
195 1 1.01 Valgus A Lateralised
326 2 1.04 Neutral A Lateralised
182 3 1.23 Neutral C Lateralised
315 4 1.26 Neutral A Lateralised
347 5 1.31 Neutral B Lateralised
403 6 1.32 Neutral A Standard
338 7 1.35 Valgus A Standard
324 8 1.37 Neutral A Lateralised
345 9 1.44 Neutral A Standard
244 10 1.51 Neutral A Standard
288 11 3.08 Neutral B Standard