| Rater 1 | Rater 2 | Rater 3 | Rater 4 | Rater 5 | Spectroscopy (SPLASH) |
---|
Rater 1 | ● | 0.665** | 0.605** | 0.779** | 0.625** | 0.383* |
Rater 2 | 0.665** | ● | 0.619** | 0.609** | 0.63** | 0.348* |
Rater 3 | 0.605** | 0.619** | ● | 0.609** | 0.532** | 0.482* |
Rater 4 | 0.779** | 0.609** | 0.609** | ● | 0.64** | 0.35* |
Rater 5 | 0.625** | 0.63** | 0.532** | 0.64** | ● | 0.253* |
median | | | | | | 0.35 |
- Interobserver agreement and correlation of the SPLASH-technique with the modified Goutallier Classification. The mean R for interobserver reliability was ρ =0.62. Correlation between the modified Goutallier Classification and the spectroscopic fat measurement with the SPLASH technique was ρ = 0.35. Correlation was measured using Spearman’s rank correlation test. (*p < 0.05) (**p < 0.01)