Table 1 Results for flexion (active and passive), knee pain, satisfaction with knee and feel of knee preoperatively and at 3 months, 6 months and 1 year follow up

From: Do patients care about higher flexion in total knee arthroplasty? A randomized, controlled, double-blinded trial

Type of prosthesis

Pre-operative

3 months

6 months

1 year

 

Flexion – passive (mean (range))

Standard CR TKA

116 (range 70–140)

115 (range 90–133)

117 (range 105–130)

120 (range 104–146)

High-flex PS TKA

118 (range 80–140)

119 (range 70–135)

123 (range 105–138)

127 (range 107–146)

p-value

0.61

0.18

0.0012

0.0012

 

Flexion – active (mean (range))

Standard CR TKA

-

109 (range 90–125)

111 (range 96–128)

114 (range 90–135)

High-flex PS TKA

-

113 (range 70–130)

115 (range 98–130)

121 (range 105–140)

p-value

-

0.14

0.04

0.0011

 

Knee pain (median (range))

Standard CR TKA

-

2 (range 0–5)

2 (range 0–5)

0 (range 0–8)

High-flex PS TKA

-

2 (range 0–9)

1 (range 0–7)

0 (range 0–8)

p-value

-

0.43

0.85

0.94

 

Satisfaction with knee (median (range))

Standard CR TKA

-

8 (range 4–10)

8 (range 4–10)

9 (range 3–10)

High-flex PS TKA

-

8 (range 1–10)

9 (range 3–10)

9 (range 4–10)

p-value

-

0.50

0.56

0.61

 

Feel of the knee (median (range))

Standard CR TKA

-

8 (range 2–10)

8 (range 2–10)

9 (range 0–10)

High-flex PS TKA

-

7 (range 0–10)

8 (range 0–10)

9 (range 0–10)

p-value

-

0.30

0.64

0.53