Skip to main content

Table 7 Values of central tendency of the measures taken with an inclinometer by the 5 examiners in the first and second measure (a week later).

From: Reliability of goniometric measurements in children with cerebral palsy: A comparative analysis of universal goniometer and electronic inclinometer. A pilot study

Measurement

Examiner

Mean

CI 95%

Median

Min.

Max.

K-S (p)

1

1

41.50

32.16-50.84

38.50

26

61

0.859

 

2

33.63

22.10-45.15

30.00

17

57

0.481

 

3

33.00

18.82-47.18

28.50

17

63

0.385

 

4

32.25

16.74-47.76

22.50

19

63

0.311

 

5

36.75

24.55-48.95

31.50

19

60

0.602

2

1

37.88

28.38-47.37

34.00

23

54

0.813

 

2

42.63

31.71-53.54

38.50

28

63

0.753

 

3

36.13

25.08-47.17

31.00

20

57

0.410

 

4

36.13

23.27-48.98

36.00

16

58

0.993

 

5

33.38

17.66-49.09

25.00

11

65

0.569

  1. Normality tests of the measurements performed by each examiner.
  2. *K-S (Kolmogorov-Smirnov): normality test. We consider that normality should not be rejected if p > 0.05.